Installation Guide
NXA-KLB Kensington Lock Bracket for NXT-1200V and -VG Series Panels
Overview
The NXA-KLB (FG2259-10) is an optional accessory for AMX Table Top (NXT-) 1200V
and VG-Series touch panels, which allows you to use a standard Kensington Lock
System to prevent theft.
The Kensington Lock System itself (including lock, key and security cable) is sold
separately.
The Kengsington Lock System is a security system from Kensington Technology
Group (www.kensington.com) that discourages the theft of portable computers and
other devices (in this case touch panels) by using a security cable and lock to anchor
the panel to an object in the room. The security cable is looped through a permanent
object in the room, then looped through itself and locked into the slot. Once secured in
this way, the panel cannot be removed from its location unless it is unlocked (using the
key that comes with the Kensington Lock assembly).
The NXA-KLB Bracket attaches to the base of the Table Top 1200V and VG-Series
panels (listed below) using keyed-lock securing screws that can only be removed with
the included AMX Keyed-Lock screw driver adapter. This screwdriver head fits into
most hex-type screwdrivers or electric drills.
There are two versions of the Bracket included with the kit, as indicated in FIG. 1:
β’ The Flat Lock Bracket fits neatly into the rear of the panelβs base, allowing you
to close the rear connector plate cover on the base while the panel is secured.
β’ The Raised Lock Bracket also allows you to use the Kensington Lock System
to secure the panel, while providing a surface to which you can secure incoming
cables.
Product Specifications
Preparing the Touch Panel to Install the NXA-KLB
1. Gently place the touch panel LCD facedown onto a soft cloth to expose the
under-side of the base and prevent scratching of the LCD (FIG. 2).
β’You may find it easier to handle the panel if you carefully detach all connectors.
2. Tilt the base forward so that the bottom surface of the base is easily accessible.
This provides access to the underside of the unit and exposes the securing loca-
tion for the Kensington Lock Bracket (FIG. 2).
3. Determine which type of bracket (Raised or Flat) you will be installing:
β’ If your installation requires secured cables, use the Raised Lock Bracket.
β’ If your installation requires a low-profile security solution, use the Flat Lock
Bracket.
Method A: Installing the Raised Lock Bracket
Note that once installed, the shape of the Raised Lock Bracket will not allow the
Connector Plate Cover on the base of the panel to be closed.
1. Raise the Connector Plate Cover, and align the openings on the bottom of the
Raised Lock Bracket to the securing locations on the Base Plate of the panel
(FIG. 2).
2. Insert two Keyed-Lock Securing Screws into their respective locations (FIG. 3).
3. Use the Keyed-Lock screwdriver adapter to tighten these screws, securing the
Raised Lock Bracket to the base plate (FIG. 4).
4. Thread the incoming cables through the opening between the bottom of the
Raised Bracket and the Base Plate (FIG. 4).
5. Reconnect the cables (on the rear connector plate).
6. Thread a tie-wrap (not included) through the center pair of circular openings on
the bracket (FIG. 5) and use it to secure all of the NXA-MTC/RGB cables to the
bracket. Trim off any excess length on the tie-wrap (if necessary).
FIG. 1 NXA-KLB Components
NXA-KLB Specifications
Compatible AMX
Touch Panels:
β’ NXT-1200V, 12" Modero Video Table Top Panel (FG2250-60)
β’ NXT-1200VG, 12" Modero Multimedia Table Top Panel (FG2250-61)
β’ NXT-1500VG, 15" Modero Multimedia Table Top Panel (FG2252-61)
β’ NXT-1700VG, 17" Modero Multimedia Table Top Panel (FG2257-61)
Requirements: β’ The NXA-KLB must be used with a standard Kensington Lock System
Note: The Kensington Lock System must be purchased separately, and is
not provided by AMX.
Included
Accessories:
β’ Raised Lock Bracket (with cable tie down) (black)
β’ Flat Lock Bracket (black)
β’ AMX Keyed-Lock screwdriver adapter
β’ Keyed-Lock Securing Screws (5)
Raised Lock Bracket
Flat Lock Bracket
Keyed-Lock
Securing Screws
AMX Keyed-Lock screwdriver adapter
(fits into any standard hex-type
screwdriver or drill)
FIG. 2 Location of the securing locations on an NXT (Table Top) panel
FIG. 3 Raised Kensington Lock Bracket Components and Installation
FIG. 4 Raised Securing locations
Base plate
Connector plate cover (open to access the
Securing locations for Kensington Lock Brackets
Touch Panel glass (facing down)
connectors on the rear of the base)
Raised Lock Bracket
Keyed-Lock Securing Screws
Kensington Lock/Security Cable
assembly (not included)
AMX Keyed-Lock screwdriver adapter
Connector plate cover
Securing locations
Thread incoming cables through this
Base Plate
Raised Lock Bracket
Kensington Lock/Security Cable
assembly (not included)
opening between the Bracket
and the Base
AMX Corporation reserves the right to alter specifications without notice at any time.
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
036-004-2870 4/05 Β©2005
AMX Corporation. All rights reserved. The AMX logo is a trademark of AMX Corporation. AMX reserves the right to alter specifications without notice at any time.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 β’ 800.222.0193 β’ fax 469.624.7153 β’ technical support 800.932.6993 β’ www.amx.com
93-2259-10 REV: A
7. Assemble the Kensington Lock/Security Cable (not included). Refer to the doc-
umentation provided by the lock manufacturer for details.
8. Open the Lock to rotate the lock mechanism so that it can be inserted into the
slot on the top center of the Raised Lock Bracket (FIG. 6).
Method B: Installing the Flat Lock Bracket
1. If you removed the connectors previously, re-insert them into their proper loca-
tions on the touch panel. This ensures that the Flat Bracket will not obstructing
any of the connectors on the rear panel.
2. Align the openings on the bottom of the Flat Lock Bracket to the securing
locations on the side of the touch panel connector plate (located under the left
connector plate cover, as indicated in FIG. 7).
3. Insert two Keyed-Lock Securing Screws into their respective locations (FIG. 7).
4. Use the AMX Keyed-Lock screwdriver adapter to tighten the screws and
secure the Flat Lock Bracket to the base plate (FIG. 7).
5. Assemble the Kensington Lock/Security Cable (not included). Refer to the doc-
umentation provided by the lock manufacturer for details.
6. Open the Lock to rotate the lock mechanism so that it can be inserted into the
opening in the top of the Flat Lock Bracket (FIG. 8).
FIG. 5 Thread a tie-wrap through the center holes on the Raised Lock Bracket
FIG. 6 Lock mechanism and insertion location
Incoming cables
Lock insertion slot
Kensington Lock/Security
Cable assembly
(not included)
Security key
(not included)
Raised Lock Bracket
FIG. 7 Flat Lock Bracket - Components and Installation
FIG. 8 Lock mechanism and insertion point
Flat Lock Bracket
Kensington Lock/Security
Keyed-Lock Securing Screws (2)
Security key
Connector plate cover
Cable assembly
(not included)
(not included)
Base
AMX Keyed-Lock screwdriver adapter
Base Plate
Lock mechanism
Lock insertion point
Security key
(not included)
Kensington Lock/Security Cable
assembly (not included)
Flat Lock Bracket
Product specificaties
Merk: | AMX |
Categorie: | slot |
Model: | NXA-KLB |
Kleur van het product: | Zwart |
Compatibiliteit: | Modero V\r\nModero VG |
Diameter van de kabel: | - mm |
Heb je hulp nodig?
Als je hulp nodig hebt met AMX NXA-KLB stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding slot AMX
13 November 2023
Handleiding slot
- slot Honeywell
- slot Abus
- slot Acco
- slot Aqara
- slot Axa
- slot Be Cool
- slot Burg-Wachter
- slot Heidemann
- slot Kensington
- slot Kogan
- slot Logilink
- slot Manhattan
- slot Master Lock
- slot Nemef
- slot Newstar
- slot SECURITY Plus
- slot Silverline
- slot Sweex
- slot Targus
- slot Olympia
- slot Steren
- slot Tryten
- slot Hamlet
- slot SIIG
- slot Extel
- slot PNY
- slot Tripp Lite
- slot Kidde
- slot Chief
- slot Chamberlain
- slot Lindy
- slot Kindermann
- slot Homematic IP
- slot StarTech.com
- slot Kwikset
- slot Vimar
- slot Panduit
- slot V7
- slot Kasp
- slot Squire
- slot Unicol
- slot TooQ
- slot Nuki
- slot Multibrackets
- slot Rocstor
- slot Welock
- slot Middle Atlantic
- slot Lockly
- slot SOREX
- slot Eura
Nieuwste handleidingen voor slot
20 November 2024
17 November 2024
12 November 2024
25 September 2024
11 September 2024
5 September 2024
5 September 2024
5 September 2024
27 Augustus 2024
27 Augustus 2024