QUICK START GUIDE
HPX- -600/900/1200 NA HydraPort 6, 9, 12 Module Connection Ports
Overview
The HPX- - - -600/900/1200 NA family of HydraPort Connection Ports (AMX FG560
xyz-NA) is built to accommodate the diverse connection needs of conference and
meeting room - - visitors. The HPX 600/900/1200 NA are designed to be mounted
into a horizontal surface such as a conference room table or lectern in order to
provid udio/e connectivity for power, anetworking, video and control.
Specific connectivity is accomplished by populating the HydraPort Base
Assembly with various modules. Each base includes a single US/NAM power
outlet module already installed.
FIG. 1 AMX HydraPort Base Assembly
AMX offers six (6) versions o f the Hydraport Base Assembly for North America:
H - -PX 600/900/1200 NA HYDRAPORT BASE ASSEMBLIES
HPX- - 600BL NA
AMX- -FG560 01B- NA
6M Capacity, Black
HPX- - 600SL NA
AMX- -FG560 01S- NA
6M Capacity, Silver
HPX- - 900BL NA
AMX- -FG560 02B- NA
9 M Capacity, Black
HPX- - 900SL NA
AMX- -FG560 02S- NA
9M Capacity, Silver
HPX- - 1200BL NA
AMX- -FG560 03B- NA
12M Capacity, Black
HPX- - 1200SL NA
AMX- -FG560 03S- NA
12M Capacity, Silver
ATTENTION with : Each base assembly comes one (1) US/NAM (Type A/B)
power outlet, -pre installed. nly one (1) power outlet may be In North America, o
installed in any Hydraport Base Assembly.
ATTENTION: Only a professional, AMX-qualified installer should perform this
installation. Installation must conform to all local codes. This product may not
be installed by the end- user.
Accessories
Hydraport Base assemblies come with the following accessories:
β€’ Two (2) Table adhesiveS ”- / pacers (for use in tables 0.5 0.75" thick) w
β€’ Eight (8) Cable Routing Clips
Compatible HydraPort Modules
Please refer to the Architectural Connectivity s product page at AMX.com for a
complete listing of compatible HydraPort Connection Modules
Installation of the HydraPort Base Assembly
The following sections describe the preparation, installation and setup of the
HydraPort Base Assembly. A typical installation will include several various
HydraPort modules.
Each HydraPort module has specific instructions for terminating their
connections. Refer to each m iodule’s nstallation guide during the installation of
the HydraPort system.
Note: Read these instructions in their entirety before beginning the installation. The
installation requires specific steps to be performed in specific order.
CAUTION: This installation requires specific woodworking skills. This installation
should be performed by an experienced person, comfortable with these types of
woodworking operations. Improper installation may result in damage to the
mounting surface. AMX is not responsible for damage caused by improper
installation.
1) Select a Suitable Location for the HydraPort Base Assembly
The following table indicates the space requirements for installing the unit:
M ODEL
H EIGHT
WIDTH
LENGTH
HPX- - 600BL NA
Base Height:
4.37” (111 mm)
With RCMs:
11.3” (287 mm)
5.43”
(138 mm)
8.19” (208 mm)
HPX- - 600SL NA
HPX- - 900BL NA
11.14” (283 mm)
HPX- - 900SL NA
HPX- - 1200BL NA
14.09” (358 mm)
HPX- - 1200SL NA
The HydraPort system requires a mounting surface from 0.5” (13mm) to 2”
(51mm) thick. T . hin surfaces may require use of included spacers
Note: Care should also be taken to ensure that the HydraPort system does not interfere with
the normal use of the work space. For example, on a table or work surface, ensure that the
system does not interfere with the user's legs when they are seated at the table.
2) iCut the Hole n the Mounting Surface
The Hydraport Base Assembly a paper template includes to locate the ideal
installation spot, and to mark the perimeter for cutting the surface. The following
table provides the hole cutout dimensions for the HydraPort Base Assembly:
WIDTH
LENGTH
4.84”
(123 mm)
7.64” (194 mm)
10.59” (269 mm)
13.54” (344 mm)
1. Use the template or measure the tabletop or other mounting surface to
locate the desired position of the HydraPort Base Assembly.
2. Use the cutout template to mark the edges of the cutout.
Note: Very little clearance exists between the HydraPort Base Assembly and the
hole cutout in the mounting surface.
Tips & Considerations:
β€’ Align the cutout carefully with the edges or other features of the mounting surface.
If the cutout is misaligned, the installed unit will be misaligned.
β€’ Take care to ensure that the top of the mounting surface is not damaged beyond the
width of the trim bezel as the cutout is made.
β€’ Use an appropriate drill & bit to make a starting hole within the boundary of the
cutout. Use an appropriate saw, such as a jigsaw to finish the cutout.
β€’ Make sure cutting tool used is appropriate for the material to be cut and will not tear
or chip the top surface.
β€’ Note that the process of making the cutout will create substantial dust and prepare
the environment appropriately.
3) Prepare the Terminations
Some HydraPort modules require some type of backside termination.
Note: Refer to the installation guide for each module to determine the required backside
termination.
FIG. 2 Inserting the Modules to HydraPort Base Assembly
Β©2023 HARMAN. All rights reserved. SmartScale, x, NetLin Enova, AMX, AV FOR AN IT WORLD, and HARMAN, and their respective logos are registered
trademarks
of HARMAN. Oracle, Java and any other company name may or brand referenced be trademarks/registered trademarks of their respective
companies.
AMX does not assume responsibility for errors or omissions. AMX also reserves alter the right to specifications without prior notice at any time. The
AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com .
3000 RESEARCH DRIVE, RICHARDSON, | | TX 75082 AMX.com 800.222.0193 469.624.8000 +1.469.624.7400 | | fax 469.624.7153
1000375659 REV:C
Last Revised 2023-05-31
β€’ & The backside termination for each module can should be completed
before the module is installed into HydraPort Base Assembly.
β€’ For terminations for which the far end of the cable is not accessible
(either because the cable has been run under carpet, in a conduit or
structure, or is otherwise fixed), the cable must be placed through the
cutout in the table prior to installation, as indicated in FIG. 2.
4) Insert the HydraPort Modules
Note: The socket-outlet (Connection to Mains Power branch circuit) shall be installed near
the equipment and shall be easily accessible.
Note the orientation of each HydraPort Module a small tab exists on one side of the -
faceplate of each module that fits tongue groove into the next module. Ensure all tabs - -in
are facing the same direction (see FIG. 2).
1. Remove one end cap of the HydraPort Base Assembly by removing the six
sheet metal screws and one pivot screw and pivot pawl assembly.
2. Slide the pre-terminated , modules one at a time, into the HydraPort Base
Assembly, and route the cables from each module out the bottom.
3. Use cable ties and one or more of the sliding clips to secure the cables as
needed to the HydraPort Base Assembly.
4. Reinstall the end cap of the HydraPort Base Assembly by installing the six
sheet metal screws and one pivot screw and pivot pawl assembly.
Note: Do not over-tighten the pivot pawl screw (i.e., do not use a high-powered drill to
tighten this screw).
5) Install Completed System Into the Mounting Surface
1. Install the unit into the cutout in the mounting surface.
β€’ Make sure that all cables from the backside terminations pass
through the cutout.
β€’ For terminations for which the far end of the cable is not accessible
(either because the cable has been run under carpet, in a conduit or
structure, or is otherwise fixed), the cable must be placed through the
cutout in the table prior to installation, as indicated in FIG. 5
2. Open the door and rotate the four mounting screws located inside and at
each end of the HydraPort base assembly in order to rotate the retaining
tabs out under the mounting surface.
Note: Make sure that the retaining tabs are down and folded out of the way prior to installing
the unit in the mounting surface.
3. Carefully tighten the mounting screws until the mounting tabs contact the
backside of the mounting surface and torque to 8 in-lbs (FIG. 3). It will be
necessary to flip the cover to the opposite side to access the other two screws.
FIG. 3 HPX Base Assembly (shown mounted) – Mounting Screw Locations
Note: Do not over torque screws. To avoid damaging the mounting tabs, use a hand
Note: For surfaces less than ΒΎ" (19mm) thick, use the supplied plastic spacers by fixing them
to each end of the cutout using the supplied double sided tape (FIG. 4).
FIG. 4 Optional Spacer and Mounting Tabs Deployed
6) Install the System nto the Mounting Surfacei
1. T erminate the underside connections as required for each cable exiting the
HydraPort system.
2. Secure these cables and the power cable to either of the end caps using the supplied
wire ties (FIG. 5).
FIG. 5 Optional Spacer and Mounting Tabs Deployed
3. Secure the cables in at least one additional location after they have been secured to
the system to prevent undue snagged or stress if the cables are inadvertently kicked,
pulled. Routing clips are provided that slide into the bottom channel of the base
assembly and leave a gap to hold the cable (FIG. 6). These clips come in two
different sizes, the larger gap is for the thicker RGB+A RCM cable.
U ksing the top tab & slot, insert the panel to the mounting brac et. Make sure
the tabs are fully engaged.
FIG. 6 Bottom View with Cable Routing Clip Installed
Additional Documentaiton
For more detailed installation instructions with additional drawings, please
refer to the -HPX 600/900/1200 Installation Guide, available to view or
download from AMX.com.


Product specificaties

Merk: AMX
Categorie: Niet gecategoriseerd
Model: HPX-900-NA

Heb je hulp nodig?

Als je hulp nodig hebt met AMX HPX-900-NA stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd AMX

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd