American Standard Colony Pro 7075.002.002 Handleiding

American Standard Kraan Colony Pro 7075.002.002

Lees hieronder de 📖 handleiding in het Nederlandse voor American Standard Colony Pro 7075.002.002 (4 pagina's) in de categorie Kraan. Deze handleiding was nuttig voor 12 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
- 1 -
SINK OR
MOUNTING
SURFACE
2
3
4
1
(HAND TIGHTEN)
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2016
Thank you for selecting American Standard...
the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly-please read
these instructions carefully before you begin.
RECOMMENDED TOOLS
1
M965766 (8/16)
INSTALL FAUCET
COLONY® PRO
SINGLE CONTROL
CENTERSET
LAVATORY FAUCET
INSTALLATION
INSTRUCTIONS
7075.054 / 7075.055 / 7075.056
7075.050 / 7075.004 / 7075.005
7075.006 / 7075.002 / 7075.000
Screwdriver Adjustable Wrench Tubing CutterChannel Locks
Certied to comply with ANSI A112.18.1M
CAUTION Turn off hot and cold water
supplies before begining.
Insert FAUCET and POP-UP CABLE (1) (2) through mounting
holes of Sink or Mounting Surface.
Assemble LOCKNUTS onto SHANKS (3) (4) from under
side of Sink. Hand tight
- 2 -
2
3
4
Operate LIFT KNOB (1) to verify that
STOPPER (2) opens and closes.
CHECK OPERATION OF POP-UP
MAKE WATER SUPPLY AND WASTE CONNECTIONS
M965766 (8/16)
• Push TAIL PIECE TRAP (11) down into (C) (threaded end up).
Thread LOCKNUT WASHER GASKET (5), and (4) (3)
(Bevel side up) onto DRAIN BODY (10).
• Apply a bead of PUTTY FLANGE (D) to underside of (2).
Feed DRAIN BODY SINK up through (10) (A) and thread
the fully onto .FLANGE (2) DRAIN BODY (10)
Tighten LOCKNUT (5) rmly, keeping the pivot rod hole pointed
towards the back of the sink.
Assemble PIVOT ROD (9) Figure-2a. as shown in
Notice the position of the CONCAVE WASHER (G).
Insert PIVOT ROD DRAIN BODY (9) into (10) and tighten
PIVOT NUT (F).
Pull TAIL PIECE (11) up and thread tightly into
DRAIN BODY .(10)
Position EXTENSION ROD POP-UP ROD(7) onto (E) and tighten
THUMBSCREW (6).
Remove one end of PIVOT ROD ENDS TOGETHER WHILE SLIDING.CLIP from (8) (9) by squeezing
Insert PIVOT ROD EXTENSION ROD (9) into second or third hole in (7) and reassemble CLIP .(8)
• DROP STOPPER DRAIN BODY (1) into (10).
Adjust stopper height by repositioning EXTENSION ROD THUMBSCREW (7) and tightening (6).
INSTALL POP-UP DRAIN
1
APPROX. 20"
2
COLD
HOT
3/8" COMPRESSION
RED
BAND
BLUE
BAND
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on tting supplies are 3/8 compression. "
Connect left SUPPLY to Hot (Marked with a Red Band) (1)
and right supply to COLD wall supply.(2)
Faucet supplies are 20 long from faucet base. "
Note: If additional supply length is required, installer must
purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
1-1/4"
6
E
D
7
8
9
C
F
2
A
1
3
4
5
10
11
2a
F
G
2
1
- 3 -
M965766 (8/16)
6
7
With HANDLE in OFF position, turn on WATER(1)
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
HANDLE Operate (1) to ush water lines thoroughly.
Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
POP-UP KNOB Operate (4) and ll lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in Sink.
Release POP-UP KNOB (4) down and check all drain
connections and trap for leaks. Tighten “P”
if necessary.
To remove or replace cartridge:
– Turn valve to OFF position.
– Pull out PLUG BUTTON and remove HANDLE SCREW (1) (2).
– Pull off HANDLE (3) (4) and CAP .
– Pull out CARTRIDGE (5).
– Inspect CARTRIDGE and O-RINGS (5) (6) for debris and
clean if necessary.
– Clean MANIFOLD (7) and rinse clean.
– Reinstall CARTRIDGE and O-RINGS (5) (6) onto
MANIFOLD (7).
– Reinstall CAP and HANDLE ASSEMBLY (4) (3).
spout drips, operate handle several times from OFF to ON If
and HOT to COLD position. Do not force - handle turns only 90˚.
ADJUST HOT LIMIT SAFETY STOP
By restricting HANDLE rotation and limiting the amount of
hot water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP reduces risk of accidental scalding. To lower the (8)
maximum hot water temperature of your faucet, all you need to
do is adjust the setting on the HOT LIMIT SAFETY STOP (8).
Note: The HOT LIMIT SAFETY STOP (98 is set at the neutral
setting from the factory. Fig. A.
adjust HOT LIMIT SAFETY STOP: To
– Remove HANDLE ASSEMBLY (3) (4), CAP
– Set the CARTRIDGE STEM to the OFF position. (9)
– Lift up the HOT LIMIT SAFETY STOP 8).
– Place the HOT LIMIT SAFETY STOP in the desired GRAY (8)
SHADED AREA (10) to limit the hot water. . Fig. B
Reinstall CAP and HANDLE ASSEMBLY (4) (3).
SERVICE
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
TEST INSTALLED FITTING
5
1
4
3
OFF
ON
HOT
COLD
“P” TRAP
WASTE
OUTLET
2
2
CAUTION Turn off hot and cold water
supplies before beginning.
7
4
5
6
9
8
1
2
2.5mm HEX KEY
+HOTTER
COLDER
8 9
A
B
10
SETTING
MARKS


Product specificaties

Merk: American Standard
Categorie: Kraan
Model: Colony Pro 7075.002.002

Heb je hulp nodig?

Als je hulp nodig hebt met American Standard Colony Pro 7075.002.002 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Kraan American Standard

Handleiding Kraan

Nieuwste handleidingen voor Kraan