Air King AK917 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Air King AK917 (8 pagina's) in de categorie Heater. Deze handleiding was nuttig voor 77 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
SAVE THESE INSTRUCTIONS
www.airkinglimited.com
210575917 Rev. H 11-18 1 of 8
Bulb Heat Lamp with Fan
Models: AK917, AK927
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
injury to person, including the following:
WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer’s guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
CAUTION: FOR GENERAL VENTILATING USE ONLY.
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING: DO NOT INSTALL OVER A TUB OR
MOUNT IN A SHOWER STALL ENCLOSURE.
a) Do not install into a ceiling thermally insulated to a value greater
than R-40.
b) NEVER place a switch where it can be reached from a tub or shower.
WARNING: DO NOT USE IN KITCHENS.
WARNING: THIS UNIT IS DESIGNED AND
TESTED TO BE A SUPPLEMENTAL HEATER FOR USE
WITH A TIMER OR A SWITCH. IT IS NOT INTENDED TO BE USED AS THE
PRIMARY SOURCE OF HEAT AND CONTROLLED BY A THERMOSTAT.
INSTALLATION INSTRUCTIONS
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
WARNING: TO REDUCE THE RISK OF FIRE, DO NOT STORE
OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINITY OF THE HEATER.
SECTION 1
Preparing the Exhaust Fan
1. Unpack fan from the carton and confirm that all pieces are present. In addition to the
exhaust fan you should have:
1 - Grill
1 - Damper Assembly (attached)
4 - Mounting Rails
1 - Instruction/Safety Sheet
2. Remove the wire compartment cover by loosening the two screws holding the cover in
place (Figure 1).
3. Choose the location for your fan. To ensure the best air and sound performance, it is
recommended that the length of ducting and the number of elbows be kept to a
minimum, and that insulated hard ducting be used.
Larger duct sizes will reduce noise and airflow
restrictions. This fan will require at least 8 of "
clearance in the ceiling or wall, and will mount
through drywall up to 3/4 thick. The fan mounts "
between 16” on center joists using the provided
mounting rails.
3. Select the most convenient electrical knockout and
remove using a straight-blade screw driver (Figure 2).
SECTION 2
New Construction
1. Install the rails on the housing and position the housing next to the joist. Line up housing
so that it will be flush with the finished ceiling. Secure the ends of the rails with screws
or nails (not included) to the joists and slide the housing into the final position (Figure 3).
SECTION 3
Existing Construction
1. Set housing in position between the joist and trace an outline onto the ceiling material
(Figure 4). Set housing aside and cut opening, being careful not to cut or damage any
electrical or other hidden utilities. Install the rails on the housing and position the housing
in the previously cut hole so that it is flush with the finished ceiling. Secure the ends of
the rails to the joists (Figure 3).
www.airkinglimited.com
210575917 Rev. H 11-18 2 of 8
SECTION 4
Ducting
CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL
BUILDING CODES.
1. Remove any tape that might be holding the damper in place during shipping and connect
the ducting to the fan’s duct collar Secure in place using tape or screw (Figure 5).
clamp. Always duct the fan to the outside through a wall or roof cap.
SECTION 5
Wiring
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE
MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR
NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING
ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
NOTE: This unit includes a side access panel for wiring that does not require the removal of the
fan’s blower assembly. If you choose to wire the unit from the inside, you will need to remove the
blower assembly and internal wiring compartment. Both methods are equally effective.
1a. Run wiring from an approved wall switch Wiring Fan/Heat Bulb(s) Independently:
carrying the appropriate rating. One neutral (white), one ground (green or bare copper),
and two hot (black and blue). Secure the electrical wires to the housing with an approved
electrical connector. Make sure you leave enough wiring in the box to make the
connection to the fan’s receptacle.
1b. From where you have access to inside the fan’s junction box, connect the white wire
from the house to the white wire from the fan. Connect one hot (black) wire from the
house to the black wire from the fan (this is the fan control). Connect the second hot
(blue) wire from the house to the blue wire from the fan (this is the heat bulb control).
Connect the ground wire from the house to the green wire from the fan Use (Figure 6).
approved methods for all connections.
NOTE: On model AK927 connect the Hot (Blue) wire from the house to the two Blue wires from
the unit.
Housing
Joist Mounting Rails
Figure 3
Figure 2
Figure 1
Screws
Wire
Compartment
Cover
Figure 4
Figure 5
Figure 6
Supply from house
Black
Neutral (White)
Ground (Green or Bare)
Fan
Neutral (White)
Green
Black
By others
Blue Blue
2. Wiring Fan/Heat Bulb together: Run wiring from an approved wall switch carrying the
appropriate rating. One neutral (white), one ground (green or bare copper), and one hot
(black). Secure the electrical wires to the housing with an approved electrical connector.
Make sure you leave enough wiring in the box to make the connection to the fan’s receptacle.
2a. From where you have access to inside the fan’s junction box, connect the one white wire
from the house to the white wire from the fan. Connect the black wire from the house to
both the black and blue wires from the fan. Connect the ground wire from the house to
the green wire from the fan Use approved methods for all connections.(Figure 7).
NOTE: On model AK927 connect the hot (black) wire from the house to the black and two blue
wires from the unit.
3. Reinstall the wire compartment cover using the two screws removed in of Step 2
SECTION 1 . Make sure all wires are tucked inside of the compartment Preparing the Unit
and are not being pinched or showing through.
SECTION 6
Completing the Installation
1. Insert plug from fan into the receptacle located under the light socket (Figure 8).
2. Remove grill from carton and attach springs from grill to posts on either side of housing
(Figure 9).
www.airkinglimited.com
210575917 Rev. H 11-18 3 of 8
3. Install a 250 watt maximum, R-40 Type A heat lamp (not included) into the socket and
center the grill around the lamp.
NOTE: Model AK927 uses 2 - 250 watt maximum R-40, Type A heat lamps.
4. Restore power and test your installation.
SECTION 7
Use and Care
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
CAUTION: ALLOW LAMP(S) TO COOL BEFORE CLEANING THE UNIT
OR REPLACING THE LAMPS.
NOTE: On installations where the ventilation fan and heat lamps are controlled independently:
After extended use of the heat lamps without the ventilation fan operating, temperature sensing
devices inside the unit may engage the ventilation fan for a time to maintain conditions inside
of the unit enclosure. Once conditions inside of the unit enclosure are similar to room ambient
conditions, the fan will disengage. This fan cycling will repeat as needed.
1. Cleaning the Grill: Remove heat lamp(s) and detach grill springs from posts to release grill
from housing. Use a mild detergent, such as dishwashing liquid, and dry with a soft cloth.
NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry grill before
reinstalling. Refer to instructions in to reinstall grill.Section 6 Completing the Installation,
2. Cleaning the Fan Assembly: Wipe all parts with a dry cloth or gently vacuum the fan.
NEVER IMMERSE ELECTRICAL PARTS IN WATER.
CAUTION: ALLOW LAMP(S) TO COOL BEFORE CLEANING THE UNIT
OR REPLACING THE LAMPS.
3. Changing the Heat Lamps: Disconnect power to the unit. Unscrew heat lamp(s) from
lamp holder and replace with 250 watt maximum, R-40, type A heat lamp.
Figure 8
Figure 9
Grille
Ressort
Montant
Figure 7
Supply from house
Black
Neutral (White)
Ground (Green or Bare)
Fan
Neutral (White)
Green
Black
By others
Blue


Product specificaties