Air King AK55L Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Air King AK55L (12 pagina's) in de categorie Heater. Deze handleiding was nuttig voor 70 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
SAVE THESE INSTRUCTIONS
www.airkinglimited.com
210575055 Rev. H 11-18 1 of 12
Exhaust Fan with Heater
Models: AK55L, AKF55
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
injury to person, including the following:
WARNING: TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK AND INJURY TO PERSON,
OBSERVE THE FOLLOWING:
a) Use this heater only as described in this manual. Any other use not recommended
by the manufacturer may causere, electric shock, or injury to persons.
b) Operate heater only when grille is installed.
c) Before servicing or cleaning the unit, switch power off at service panel and
lock the service disconnecting means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.
d) Do not operate any heater after it malfunctions. Disconnect power at service
panel and have heater inspected by a reputable electrician before reusing.
e) Do not use outdoors.
f) Do not insert or allow foreign objects to enter any ventilation or exhaust
opening as this may cause and electric shock or fire, or damage the heater.
g) To prevent a possible fire, do not block air intakes or exhaust in any manner.
WARNING: TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK AND INJURY TO PERSON,
OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards, including fire-related
construction.
b) For supply connections, use wires suitable for at least 75° C (167° F).
c) Use copper wire only.
d) Sufficient air is needed for proper combustion and exhausting of gases through
the flue (chimney) of fuel burning equipment to prevent back drafting. Follow
the heating equipment manufacturer’s guideline and safety standards such
as those published by the National Fire Protection Association (NFPA) and the
American Society for Heating, Refrigeration, and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
e) When cutting or drilling into wall or ceiling, do not damage electrical wiring and
other hidden utilities.
CAUTION: FOR GENERAL VENTILATING USE ONLY.
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
f) A heater has hot and arcing or sparking parts inside. Do not use in areas where
gasoline, paint, or flammable vapors or liquids are used or stored.
g) Ducted fans must always be vented to the outdoors.
h) This unit must be grounded.
i) To avoid motor bearing damage and noisy and/or unbalanced impellers, keep
drywall spray, construction dust, etc. off power unit.
j) This heater is hot when in use. To avoid burns, do not let bare skin touch hot
surfaces.
k) Extreme caution is necessary when any heater is used by or near children or
invalids and whenever the heater is left operating and unattended.
IMPORTANT INSTRUCTIONS: Read all instructions before installing or using
exhaust fan.
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY
SOLID-STATE SPEED CONTROL DEVICE.
WARNING: DO NOT INSTALL OVER A TUB OR
MOUNT IN A SHOWER STALL ENCLOSURE.
WARNING: DO NOT USE IN KITCHENS.
WARNING: THIS UNIT IS DESIGNED AND TESTED TO
BE A SUPPLEMENTAL HEATER FOR USE WITH A TIMER OR A
SWITCH. IT IS NOT INTENDED TO BE USED AS THE PRIMARY SOURCE OF HEAT
AND CONTROLLED BY A THERMOSTAT.
Motor is thermally protected.
Electrical Ratings: AK55L - 120V, 60Hz., 11.3A
AKF55 - 120V, 60Hz., 11.3A
INSTALLATION INSTRUCTIONS
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
WARNING: TO REDUCE THE RISK OF FIRE, DO NOT STORE
OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINITY OF THE HEATER.
SECTION 1
Preparing the Exhaust Fan
1. Unpack fan from the carton and confirm that all pieces are present. In addition to the
exhaust fan you should have:
1 - Grill with Light Lens
4 - Mounting Rails
1 - Instruction/Safety Sheet
2. Remove the two hex nuts holding the light reflector in place. Keep the reflector and nuts
in the carton until needed so they do not get damaged or lost (Figure 1).
3. Remove the fan’s venturi assembly, which is secured in place with one screw through the
venturi Keep the venturi assembly and the grill in the carton until needed so (Figure 2).
they do not get damaged or lost.
WARNING: DO NOT INSTALL OVER A TUB OR MOUNT IN A
SHOWER STALL ENCLOSURE.
4. Choose the location for your unit. To ensure the best air and sound performance, it
is recommended that the length of ducting and the number of elbows be kept to a
minimum, and that insulated hard ducting be
used. Larger duct sizes will reduce noise and
airflow restrictions. This fan will require at
least 7" of clearance in the ceiling, and will
mount through drywall up to 3/4" thick. The
fan mounts between 16" on center joists using
the 4 provided mounting rails.
5. Remove the electrical knockouts using a
straight-blade screw driver .(Figure 3)
SECTION 2
New Construction
1. Install the rails on the housing and position the housing next to the joist. Line up housing
so it will be flush with the finished ceiling. Secure the ends of the rails with screws or
nails (not included) to the joists and slide housing into final position (Figure 4).
www.airkinglimited.com
210575055 Rev. H 11-18 2 of 12
SECTION 3
Existing Construction
1. Set housing in position between the joist and trace an outline onto the ceiling material
(Figure 5). Set housing aside and cut opening, being careful not to cut or damage any
electrical or other hidden utilities. Install the rails on the housing and position the housing
in the previously cut hole so that it is flush with the finished ceiling. Secure the ends of the
rails to the joists with screws or nails (not provided) to ensure proper installation (Figure 4).
SECTION 4
Ducting
CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND
NATIONAL BUILDING CODES.
1. Remove any tape that might be holding the damper in place. Connect the ducting to the
fan’s duct collar and secure in place using tape or screw clamp. Always duct (Figure 6)
the fan to the outside through a wall or roof cap.
SECTION 5
Wiring
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.
WARNING: THIS UNIT MUST BE WIRED ON A SEPARATE 15
AMP CIRCUIT.
WARNING: USE APPROPRIATELY SIZED COPPER
CONDUCTORS ONLY RATED FOR AT LEAST 75°C.
Figure 1
Nuts
Figure 2
Screw
Figure 3
Figure 4
Housing
Joist
Mounting Rails
Figure 5
Figure 6
CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE
MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR
NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING
ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
1. Run wiring from wall switches carrying the appropriate rating. One neutral (white), one
ground (green or bare copper), and three hot (red, blue, and yellow leads connected to
the switch, one for each function). Secure the electrical wires to the housing with an
approved electrical connector. Make sure you leave enough wiring in the box to make the
connection to the fan’s receptacles.
2. Connect the White wire from the house to the three White wires from the fan. Connect one
Hot (Blue) wire from the wall switch to the Blue wire from the fan (this is the fan control).
Connect second Hot (Red) wire from the wall switch to the Red wire from the fan (this is
the heat control). Connect the third Hot (Yellow) wire from the wall switch to the Yellow
wire from the fan (this is the light control). Connect the ground wire from the house to the
Green wire from the fan . Use approved methods for all connections.(Figure 7)
SECTION 6
Completing the Installation
1. Reinstall the fan’s venturi by holding it at approximately a 45 degree angle, hook the two
tabs on the venturi into the slots on the housing and secure in place by tightening the
venturi screw. Rotate the blower wheel by hand to ensure it spins freely (Figure 8).
2. Insert the plug from the heating unit into the receptacle marked “HEAT”, and the plug
from the fan into the receptacle marked “VENT”(Figure 9).
www.airkinglimited.com
210575055 Rev. H 11-18 3 of 12
3. Remove grill from carton and open light lens area by pushing in on the two tabs of the
light lens and pulling outward from lens. The lens will swing open on the connector bars.
DO NOT remove the lens from the grill (Figure 10).
4. Install light reflector into grill by lining up the posts on grill with the holes in light reflector
(Figure 11). Raise light reflector and grill up to housing and insert plug from light into
receptacle marked “LIGHT” (Figure 9).
5. Attach light reflector in place with the two nuts removed during in Step 2 SECTION 1
Preparing the Unit so grill fits snuggly against ceiling (Figure 12).
Figure 8
Heater
Figure 9
Vent
Connector
Bar
Tabs
Figure 10
Post
Hole
Post
Figure 11
Nut
Figure 12
Figure 7 Supply from house
Blue
Ground (Green
or Bare)
Fan
Green
Red
Neutral (White)
By others
Switch
(by others)
Black Yellow


Product specificaties

Merk: Air King
Categorie: Heater
Model: AK55L

Heb je hulp nodig?

Als je hulp nodig hebt met Air King AK55L stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Heater Air King

Handleiding Heater

Nieuwste handleidingen voor Heater