Thank you for selecting Aiphone for your communication and security needs. Please read this manual carefully before installation,
and keep it in a safe place for future reference. Also read the installation manuals for the other devices included in your system.
Please note that the illustrations in this manual may differ from the actual product.
JP-4MED
HANDS-FREE COLOR VIDEO INTERCOM MASTER STATION
JPW-BA
LONG DISTANCE ADAPTOR
JP-8Z
DISTRIBUTION ADAPTOR
INSTALLATION MANUAL
JP-4MED
JPW-BA
JP-8Z
2
CONTENTS
PRECAUTIONS ................................ 3
WARNING ........................................... 3
CAUTION ............................................ 3
GENERAL PRECAUTIONS ............... 3
NOTICES ............................................ 3
PACKAGE CONTENTS ................... 4
CONNECTIONS ............................... 4
Notes about handling cables .......... 4
Wiring distance ................................ 5
Selecting power supply method ..... 6
Basic system connection ................ 8
Expanding the system ................... 10
Connecting external devices
(using the option connectors) ...... 12
MOUNTING ................................... 13
Mounting locations ......................... 13
Mounting procedure ....................... 14
SETTINGS AFTER
INSTALLATION ............................. 16
Setting list ........................................ 16
[INSTALL] menu .............................. 16
Setting for inputs and outputs ....... 17
Door release settings
[SET DOOR RELEASE] ................... 18
Initializing station [INITIALIZE] ..... 19
Identifying software version
[SOFTWARE VERSION] ................. 19
TECHNICAL DATA AND
PRECAUTIONS .............................. 19
WARRANTY .................... Back cover
Term de nition
This manual uses "residential station" as the
common term for "master station" and "sub master
station".
3
PRECAUTIONS
Prohibited
Do not dismantle unit
Keep unit away from water
General precautions
WARNING
Negligence could result in death or serious injury.
1. Do not dismantle or alter the unit. Fire or electric shock could
result.
2. Keep the unit away from water or any other liquid.
Fire or electric shock could result.
3. High voltage is present internally. Do not open the case.
Electric shock could result.
4. Do not connect any non-speci ed power source to the +, -
terminals. Also, do not install two power supplies in parallel to a
single input. Fire or damage to the unit could result.
5. Do not connect any terminal on the unit to an AC power line.
Fire or electric shock could result.
6. Do not use power supply with a voltage other than speci ed.
Fire or electric shock could result.
7. Keep AC cord from being marred or crushed. If the AC cord is
damaged, re or electric shock could result.
8.
Do not plug or unplug unit with wet hands. Electric shock could
result.
9. Insert AC plug completely and securely into AC outlet.
Otherwise, re or electric shock could result.
10.
Periodically check for and remove dust on the power plug. If
dust is left, it could cause the power plug to heat up, resulting in
re.
11.
Do not put any metal or ammable material into the unit through
the openings. Fire, electric shock, or unit trouble could result.
CAUTION
Negligence could result in injury or damage to property.
1.
Do not install or make any wire terminations while power supply
is plugged in. It can cause electrical shock or damage to the unit.
2. When mounting the unit on a wall, install the unit in a
convenient location, but not where it could be jarred or
bumped. Injury could result.
3. Before turning on power, make sure wires are not crossed or
shorted. Fire or electric shock could result.
4.
Do not install the unit in locations subject to frequent vibration or
impact. It may fall or tip over, resulting in damage to the unit or
personal injury.
5. For power supply, use Aiphone power supply model speci ed
for use with system. If non-speci ed product is used, re or
malfunction could result.
6. Do not apply high pressure on the screen. If fractured, injury
could result.
7. If LCD is punctured, do not touch the liquid crystal inside.
In ammation could result. If contact should occur, ush or rinse
area with water thoroughly and consult your doctor.
8. Do not put anything on the unit or cover the unit with cloth, etc.
Fire or unit trouble could result.
9. Do not install the unit in any of the following locations. Fire,
electric shock, or unit trouble could result.
Places under direct sunlight or near heating equipment that *
varies in temperature.
Places subject to dust, oil, chemicals, hydrogen sul de (hot *
spring).
Places subject to moisture and humidity extremes, such as *
bathrooms, cellars, greenhouses, etc.
Places where the temperature is quite low, such as inside a *
refrigerated area or in front of an air conditioner.
Places subject to steam or smoke (near heating or cooking *
surfaces).
Where noise generating devices such as dimmer switches or *
inverter electrical appliances are closeby.
10. Be sure to perform a call test or check the volume with the
handset on the hook. If you operate the hook switch with the
handset on your ear, a sudden call etc. may arrive causing
damage to your ear.
11. The unit must be installed and wired by a quali ed technician.
GENERAL PRECAUTIONS
1. Keep the unit more than 1 m (3.3') away from radio or TV sets.
2. Keep the intercom wires more than 30cm (12'') away from AC
100-240V wiring. AC induced noise and/or unit malfunction could
result.
3. Comply with all third party manufacturing speci cations that will be
used with this system (sensors, door releases, etc.).
4. If it is used close to a cellular phone, the unit may malfunction.
5. The unit can be damaged if dropped. Handle with care.
6. The unit will not work during power failure.
7. In areas where broadcasting station antennas are close by, the
intercom system may be affected by radio frequency interference.
8. All the units, except for door stations, are designed for indoor use
only. Do not use at outdoor locations.
9. This product, providing door release, should not be used as a
crime prevention device.
10. Please note the LCD panel, though manufactured with very high
precision techniques, inevitably will have a very small portion of its
image elements always lit or not lit at all. This is not considered a
unit malfunction.
11. Environmental sound around the unit may hinder smooth
communication, but this is not a malfunction.
12. The unit has audio monitoring function between residential
stations. When using this function for baby monitoring, never
install the unit within reach of children to prevent strangulation with
coil cord or wires.
NOTICES
We will under no conditions be liable for damage occurring due
to the inability to communicate due to malfunctions, problems, or
operational errors in this product.
We will under no conditions be liable for any damages or losses
resulting from this product's contents or speci cations.
This manual was created by Aiphone Co., Ltd., all rights reserved.
Copying, in part or in whole, this manual without prior permission
from Aiphone Co., Ltd. is strictly forbidden.
Please note that images and illustrations depicted in this manual
may differ from the actual ones.
Please note that this manual may be revised or changed without
prior notice.
Please note that product speci cations may be changed for the sake
of improvement without prior notice.
This system is not intended for life support or crime prevention. It is
a supplementary means of conveying information. Aiphone will under
no conditions be liable for loss of life or property which occurs while
the system is being operated.


Product specificaties

Merk: Aiphone
Categorie: Intercomsysteem
Model: JPS-4AEDF
Kleur van het product: Wit
Beeldschermdiagonaal: 7 "
Touchscreen: Ja
Connectiviteitstechnologie: Bedraad
Minimale belichting: 5 Lux
Kijkhoek, horizontaal: 170 °
Omvang optische sensor: 1/4 "
Type beeldsensor: CMOS
PTZ control: Ja
Aantal TV lijnen: 525
Binnenunit inbegrepen: Ja
Buitenunit inbegrepen: Ja
Bedrijfstemperatuur deurstation (T-T): -10 - 60 °C
Afmetingen deurstation (BxDxH): 135 x 5.6 x 209 mm

Heb je hulp nodig?

Als je hulp nodig hebt met Aiphone JPS-4AEDF stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Intercomsysteem Aiphone

Handleiding Intercomsysteem

Nieuwste handleidingen voor Intercomsysteem

Elcom

Elcom REN410X Handleiding

17 November 2024
Akuvox

Akuvox MD06 Handleiding

17 November 2024
Vimar

Vimar K40930 Handleiding

16 November 2024
Somfy

Somfy V500 Handleiding

15 November 2024
Pentatech

Pentatech VT35 Handleiding

5 November 2024
Viking

Viking K-1700-3 Handleiding

30 September 2024
Viking

Viking E-50-SS Handleiding

30 September 2024
Viking

Viking E-50-WH Handleiding

30 September 2024