ABB US/U 12.2 Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor ABB US/U 12.2 (90 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 220 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/90
Product Manual
ABB i-bus


 KNX
Intelligent Installation Systems
Universal Interface
US/U 12.2
ABB i
-bus KNX
US/U 12.2, Universal Interface, 2
- fold, FM
© 2012 ABB STOTZ- 1KONTAKT GmbH
Page
1 General ................................................................................................. 3
1.1 Product and functional overview ........................................................... 3
2 Device technology .............................................................................. 5
2.1 ....................................................................................... Technical data 5
2.2 Circuit diagram ...................................................................................... 7
2.3 Dimension drawing ............................................................................... 8
2.4 Assembly and installation ..................................................................... 8
2.5 Description of the inputs and outputs ................................................... 9
3 Commissioning................................................................................. 10
3.1 Overview ............................................................................................. 10
3.2 Parameters and communication objects ............................................ 12
3.2.1 General parameters ......................................................................... 12
3.2.2 Operating mode “Switch sensor” ...................................................... 16
3.2.3 Operating mode “Switch/Dimming sensor” ...................................... 23
3.2.4 Operating mode “Shutter Sensor” .................................................... 28
3.2.5 Operating mode “Value / forced operation” ...................................... 33
3.2.6 Operating mode “Control scene” ...................................................... 38
3.2.7 Operating mode “Control valve drive” .............................................. 48
3.2.8 Operating mode “Control LED” ........................................................ 56
3.2.9 Operation mode “Switching sequence” ............................................ 61
3.2.10 Operation mode “Multiple operation” ............................................... 66
3.3 Programming ...................................................................................... 69
4 Special functions.............................................................................. 70
4.1 Debounce time and minimum signal time ........................................... 70
4.2 Reaction on bus voltage failure .......................................................... 71
4.3 Reaction after bus voltage recovery ................................................... 71
5 Application examples....................................................................... 72
5.1 1 button operation with central function .............................................. 72
5.2 Operation of dimmable illumination .................................................... 74
5.3 Operation of shutters .......................................................................... 76
5.4 Control of scenes ................................................................................ 78
5.5 Control of a heater valve ..................................................................... 81
5.6 Switching of lighting in switching sequence ........................................ 83
5.7 Switching of lighting via multiple button pushes ................................. 85
6 Appendix ............................................................................................ 87
6.1 Switching sequence “All combinations” .............................................. 87
6.2 Value table for object “8 Bit scene” ..................................................... 88
6.3 Ordering information ........................................................................... 88
ABB i
-bus KNX
US/U 12.2, Universal Interface, 2
- fold, FM
© 2012 ABB STOTZ- 2KONTAKT GmbH
This manual describes the function of the Universal Interface US/U 12.2 with its
application program
Binary Input Display Heat 12f/1.
Subject to
changes and errors excepted.
Exclusion of liability:
Despite checking that the contents of this document match the hardware and
software, deviations cannot be completely excluded. We therefore cannot accept any
liability for this. Any necessary correcti
ons will be incorporated in new versions of the
manual.
Please inform us of any suggested improvements.


Product specificaties

Merk: ABB
Categorie: Niet gecategoriseerd
Model: US/U 12.2
Gewicht: 68 g
Breedte: 54 mm
Diepte: 54 mm
Hoogte: 19 mm
Gewicht verpakking: 80 g
Breedte verpakking: 92 mm
Diepte verpakking: 23 mm
Hoogte verpakking: 65 mm
Certificering: IP20
Duurzaamheidscertificaten: RoHS, WEEE
Naleving van duurzaamheid: Ja
Aantal kanalen: 12 kanalen
Module type: Analoog
Signaal directie: Invoer/uitvoer

Heb je hulp nodig?

Als je hulp nodig hebt met ABB US/U 12.2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd ABB

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd