1.0 General
1.1 The 3M Fibrlok II Universal Optical Fiber Splice
2529 provides permanent mechanical splices for
singlemode or multimode fiber having 125 µm
diameter cladding. The 2529 universal splice is
designed to accommodate any combination of fibers
with coating diameters from 250 µm to 900 µm.
1.2 All 2529 splices are gray in color and are marked
with the 3M Fibrlok II logo on the splice cap.
1.50" (38.1 mm)
0.250"
(6.4 mm)
.150"
(3.8 mm)
Jacket
Cap
End Plug
(each end)
Fiber Entry Port
(each end)
April 2015
78-8128-0163-3-G 3
3M Fibrlok II Universal Optical
Fiber Splice 2529
Instructions
2 78-8128-0163-3-G
1.4 Tools and Materials Required are as follows:
3M Fibrlok Assembly Tool 2501
Plastic coating (buffer) stripper
Reagent-grade isopropyl alcohol
Lint-free wipes
Cleaver
3M Fibrlok II video instructions (optional)
3M Fibrlok Tool Kit (optional)
1.5 Some compatible 3M Fiber Splice Tray product
numbers are: 2522, 2524, 2523, 2527
2.0 Splicing Set-Up
2.1 The splicing area should be clean, dry and well-
lit. A clean, well-organized splicing area will
improve splice efficiency and minimize the risk of
contamination of fibers or splices.
2.2 Open the buffer tubes, expose and clean the fibers
per your company practice.
Note: Storage, use and disposal of isopropyl alcohol
should be per your company health, safety and
environmental instructions. Refer to solvent label
or Safety Data Sheet.
2.3 See Section 6.0 for recommended procedures for
fiber organization and splice storage.
1.3 3M Fibrlok Assembly Tool 2501
Fiber Alignment
Guides (2)
Toggle Arm
Fiber Retention
Pad
Splice Holding Cradle
Mounting Holes (4) Base
Toggle Arm
Fiber Retention
Pad
Fiber Cleave Length
Gauge (both ends of tool)
Finger Cutout
Instruction Label (2)
Pivoted Handle
(shown open)
378-8128-0163-3-G
2.4 Remove 3M
Fibrlok II Universal Splice 2529
from its protective package. Load the splice into
the assembly tool by pressing firmly at the ends
of the splice.
Note: Carefully follow health, safety and environmental
information on Fibrlok II splice label or Safety
Data Sheet.
CAUTION
May cause minimal eye irritation.
Contains: Phenylmethyl silicone (63148-58-3), hydrophobic silica (68611-44-9).
Precautions: Avoid eye contact. Wash hands before eating or smoking.
First Aid:
Eye Contact: Immediately flush eyes with plenty of water while holding eyelids
open and continue flushing for ten minutes. Call a physician.
Skin Contact: Wash with soap and water.
Production Information Source: Material Safety Data Sheet or 3M Company,
St. Paul, MN 55144-1000, (612) 733-111-: Operator 55
2.5 If using the 3M
Fibrlok Assembly Tool 2501,
rotate the toggle arms for the appropriate fiber size.
3.0 Fiber Preparation
3.1 Remove the minimum length of fiber required to
prepare and splice the fibers.
3.2 Strip approximately 1 to 2 inches (25 mm to 51
mm) of plastic coating from the fiber using a
mechanical stripper.
Note: The stripper should be in good operating
condition to prevent scratches or other damage
to the glass cladding.
1" to 2" (25 mm - 51 mm)
3.3 Clean the bare glass by pulling the fiber through an
alcohol soaked lint-free wipe. This will remove any
fragments or dirt remaining on the fiber.
Note: Do not wipe the fibers more than two times,
and limit the time that the bare fiber is exposed
to the atmosphere.
Note: Carefully follow health, safety and environmental
information on container label or Data Sheet for
isopropyl alcohol being used.
3.4 Cleave the fiber to 12.5 mm ±0.5 mm
(0.492 ±0.020 inches).
Important: The 3M Fibrlok II Universal Splice 2529 uses
a cleave length of 12.5 mm ±0.5 mm (0.492
±0.020 inches) for both 250 µm and 900 µm
coated fibers.
Note: The cleaver should be in good operating condition
and used in accordance with the manufacturer's
instructions. It is recommended that the cleaver
provide a consistent cleave-to-coating length
within ±0.5 mm. In addition, standard cleavers
should produce cleaved ends within 2° of
perpendicular and free of major defects.
Cleavers specifically designed to produce
controlled, angled cleaves of greater than 2°,
but not more than 6°, may also be used with
the 3M Fibrlok Splice.
3.5 Check the cleave length using the 12.5 mm cleave
length gauges on the 3M Fibrlok Assembly Tool
2501. Adjust the cleaver to provide the prescribed
cleave lengths. Check cleave lengths periodically
during subsequent splicing operations.
Note: Do not allow cleaved end to contact tool.
Do not clean the fibers again after they have
been cleaved.