Wunder-Bar M4 Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Wunder-Bar M4 (12 pagina's) in de categorie Overige keukenapparatuur. Deze handleiding was nuttig voor 45 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
MBERCONTENTS PAGE NU
Installation....... . . . . . . . . . . . . . . . . . . . . ... .. .. ... .. ..... ... .. .. ... .. ..... ... .. .. ... .. ..... ... .. .. ... .. 2
Br arixing—Stand d Manifold.... .. .. ... ... ... .. .. ... .. ... ... .. .. ... ... . . .. . . . . . .. . . . . . .... 3
Flow gulator nifoldRe Ma ..... . . . . . . . . . . . . . . . ... .. .. ... .. ..... ... .. .. ... .. ..... ... .. .. ... .... 4
Configuration and Maintenance........... . . . . . . . . . . . ... ... .. .. ... .. ..... ... .. .. ... .... 5
Repair…....... . . . . . . . . . . . . . . . . . . . . ... ... .. .. ... .. ..... ... .. .. ... .. ..... ... .. .. ... .. ..... ... .. .. ... .... 6-8
Model Numbers and Buttons…....... .. ... ... .. .. ... .. ... ... .. .. ... ... .. . . . . . .. . . . . . ... 9
Sanitizing and Cleaning…………………………………………………. 10-11
Troubleshooting………………………………………………………….. 12
For 1 to 14 Button
Post-Mix
and
Juice Dis nsers pe
Standard and Flow Regulator Manifold
SERVICE AND FACTORY ASSISTANCE:
Please record your Installer/Service Agent's name and phone number here for future reference:
SERVICE AGENT NAME: _______ ___________ DATE OF INSTALLATION: _______________ _
SERVICE AGENT PHONE: ___________________ SERIAL NUMBER: ___ ___________________
Or, call the Wunder-Bar Service Hotline 1-866-WUNDERBAR (1-866-986-3372) anytime or
(707) 44 -5151 Monday through Friday, 7:00 AM to 5:00 PM Pacific Time.8
MARK 4 MANUAL 2000-504
EXPLODED PARTS DRAWINGS FOR ALL MODELS OF WUNDER-BAR POST-MIX AND JUICE
DISPENSERS CAN BE FOUND AT:
http://www.wunderbar.com/dispensing/bevera -dispensing/so -dispenser/soft-drink-so -gun-pistolge da da
POST-MIX
BEVERAGE
DISPENSER
U. S. Patent Numbers and Pending:
D656,387, D647,785, D656,001, D648,420
D648,421, D648,826, D669,308, D643,708
D648,617, D656,388, D656,002, D658,486
8,272,536, 8,448,821, 8,459,505, 9,038,986
Canadian Patent Number: 2,772,4 05
Japanese Patent Number: 5758895
™
REV040921
I
N
S
T
A
L
L
A
T
I
O
N
When you begin to install your ® Mechanical Flex Hose bar dispenser, Wunder- Bar
you will notice that all necessary mounting hardware, a hose hanger, a drip cup, a
drain tube, and the appropriate number of stainless steel input fittings are included
with each dispenser (Fig.1).
The input fittings are installed in the product manifold of the dispenser. These input
fittings are held in place by kwik klips. To remove input fittings, pull up on kwik klip
until it stops to allow removal of the fittings (Fig.2a & 2b). The Kwik Klips are color
coded: white for soda and water, black for the syrups.
1/4” straight Input Fittings are included with all
new Post-Mix Beverage and Juice Wunder-Bar®
Dispensers unless custom “Fitting Sets” are
ordered. Input fittings are available in straight,
90 degree, and 45 degree configurations with either 1/4”, 5/16”, 3/8", or 1/2" barbed
ends. 3/8” and 1/2” Input Fittings are available in two lengths: Short and L g (Fig.3a on
& 3b) to allow the two lengths to be installed staggered to accommodate braided
tubing.
Secure the soda, water,
and syrup tubes to the
Input Fittings with fer-
rules or clamps, install
the Input Fittings into
their correct manifold positi s, push the Kwik Klips wn on do
fully to lock the fittings into position. The letters and numbers
on the manifold label co es nd to the but n positions on rr po to
the dispensing handle.
Use four 2" stainless steel Phillips head screws, included in
the mounting hardware package, to secure the tube collector
and manifold assembly to the underside of the bar. Optional
Kwik Mount Kits are available for easy installation and remov-
al of the Manifold from the bar for service. (10 Brand Kwik
Mount Kit = PM10-83, 12/14 Brand Kwik Mount Kit = PM12
After all connection are made, turn on water supply, carbonator, C02, and BIB pumps.
CHECK ALL DISPENSER AND SYSTEM FITTINGS CONNECTIONS FOR LEAKS IMMEDIATELTY!
ATTENTION!
Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed, and maintained
in accordance with federal, state, and local codes. The Post-Mix Dispenser’s water supply line must be connected to the
potable water supply with adequate backflow prevention to comply with federal, state, and local
codes.
Fig.2a
VERSION 1
Fig.2b
VERSION 2
Fig.3a
VERSION 1
Fig.3b
VERSION 2
VERSION 2
2
™
Complete Hose Hanger Kit (Fig.4)
INSTALLATION INSTRUCTIONS:
(1) Position PM10-40 under the countertop, in the desired
mounting location, with the alignment line lined-up with the front edge of the
countertop. (2) Install three PM10-65 (#10 x 3/4” Phillips, Pan Head Screws) through
the three mounting holes and into the countertop, completely, until no screw threads
are visible or exposed below the screw hole mounting bosses. (3) Install one end of
the PH10-166-5 (6’ Drain Tube) onto the 0507-105 (Drip Cup) barbed drain stem, fully.
(4) Extend the other end of the PH10-166-5 (6’ Drain Tube) to the floor sink or drain.
Do not install Drain Tube end into the ice bin or sink drain.
(5) Press 0507-105 (Drip Cup) into the PM10– 40 (Hose Hanger),
making sure to secure all locking tabs (x4) on the Drip Cup to the underside
of the Hose Hanger.
Fig.4
PH10-166-5
PM10-661501-399
0507-105
PM10-40
Fig.1
REV040921
B
R
I
X
I
N
G
M
E
T
E
R
I
N
G
S
C
R
E
W
M
A
N
I
F
O
L
D
S
It will be necessary to brix your Wunder-Bar® Mechanical Flex Hose bar dispenser
before use. Either a Wunder-Bar® Syrup separator and Brix Cup (Fig.5) or a refrac-
tometer may be used. Diet products do not contain sugar and therefore diet prod-
ucts’ ratio may only be measured using a Brix Cup.
Brix ratio is the ratio of syrup concentrate to soda or water. A syrup separator (p/n
PH10-83) is designed to separate the syrup/concentrate from the soda or plain water,
allowing for proper measurement of products. A Brix Cup (p/n PH10-35) allows the
user to visually compare and confirm the ratios of soda-to-syrup and water-to-syrup.
A refractometer (Not available from Wunder-Bar) is a hand-held optical device used
to measure the amount of sugar in solution in beverages containing sugar.
In order for accurate Brix measurements or readings to be made, it will be necessary
to "ice down" the cold plate, by covering the cold plate located in the bottom of the
ice bin with a minimum of 4” to 6” of ice. If a mechanically
refrigerated beverage chilling system is to be used, instead
of a cold plate, turn ON the refrigerated, re-circulating bever-
age unit and allow it to “chill down” to normal operating tem-
perature before attempting to take Brix readings or measure-
ments. Once the cold plate or refrigerated unit have reached
temperature, dispense approximately 10 to 12 ounces of
each beverage just before attempting to “read” each prod-
ucts’ brix.
SETTING THE SODA AND WATER FLOW RATES
Set the flow rate to your specifications or to the nominal flow
rate of 5 oz of soda in 3 seconds. Dispense soda into the large chamber of the Brix Cup or into a measuring cup. Turn the
brix screw (Fig.6a, 6b) labeled "S" counter-clockwise or “out” to increase the soda flow rate or clockwise or “in” to de-
crease the soda flow rate. The brix screws are the “slot
head” screws on the product manifold. Do not turn the “Shut
-Offs” to adjust the brix ratio. The shut-offs are closest to
the input fitting side of the manifold and are open when the
Shut-Off tabs are in line with the flow of product through the
manifold (see Fig.7a & 7b). Repeat the adjustment process
to set the water flow rate to 5 oz. of water in 3 seconds.
ADJUSTING THE BRIX RATIOS
Now that the soda and water flow rates are set, product brix-
ing may begin. The "L" button corresponds to the "L" posi-
tion on the product label at the manifold. The "C" button
corresponds with the "C" position on the manifold, "T" for
"T", etc. The syrup brix screws are adjusted in the same manner as Soda and Water Brix Screws; counter-clockwise or
"out" increases flow rates, clockwise or "in" decreases flow rates. The most common ratio for Post-mix beverages is 5:1 (5
parts soda or water to 1 part syrup). However, some specialty beverages have 5.5:1 or higher ratios. Some juices and mix-
ers have ratios as low as 1:1 to 2:1. Always read the BIB (Bag-In-Box) syrup container label for ratio specifications before
starting. The small chamber (syrup side) of brix cup should fill to 1 oz. in the same
amount of time it takes to fill the large chamber 5 oz. of soda or water—confirming a
5:1 brix ratio (Fig.5). If the product was 4:1 ratio, the small chamber would ll to the
same 1 oz. mark, but the soda or water would fill to 4 oz. Repeat until all products
are properly brix ratio’d.
SECONDARY WATER BRIX SCREW (Fig.8)
All Wunder-Bar® Post-Mix and Juice dispensers have a “Secondary Water Adjust-
ment Screw” to enable juices and beverages with 2:1 and 1:1 ratios to be dispensed
through buttons located under the lower right Butterfly Plate. The Secondary Water
Brix Screw is factory set to the “open” position. Use a small bladed screwdriver to
turn the screw Clockwise or “in” to decrease water flow to achieve 2.1 to 1:1 ratios
for products like tomato juice and Bloody Mary Mix.
Fig.5
Fig.8
3
Fig.6b
VERSION 1
Fig.6a
VERSION 2
VERSION 1
Fig.7a
VERSION 2
Fig.7b
Shut-Off’s
in OPEN
Position
™
REV040921


Product specificaties

Merk: Wunder-Bar
Categorie: Overige keukenapparatuur
Model: M4

Heb je hulp nodig?

Als je hulp nodig hebt met Wunder-Bar M4 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Overige keukenapparatuur Wunder-Bar

Handleiding Overige keukenapparatuur

Nieuwste handleidingen voor Overige keukenapparatuur