CONTROL UNIT FOR COMMAND OR CENTRALIZATION MOTOR
Control unit for one electromechanical motor, centralizaon or integra-
on dry contact command.
The control unit imputs is: local impulsive command (open and close), ge-
neral impulsive command (open and close), general priority command
(open and close) dead man switch.
Prevalence of general command (dead man switch) on other controls.
CONNECTION LAYOUT TECHNCIAL FEATURES
Power supply: 230 Vac ± 10% / 50 Hz
Corr. max output: 5 A cos 1,4 / 2 A cos 0,4φ φ
Work Time: 120 seconds
Tens. output with: 230 Vac / 50 Hz
Dimensions without box: 46x46x37 mm
Terminal secon: ²2,5 mm
INPUTS AND OUTPUTS CONNECTION
1 = 230 Vac Neutral
2 = GND
3 = 230 Vac Phase
4 = COM x cont. neutral
5 = OPEN output
6 = COM x engines.
7 = CLOSE output.
8 9 - = COMMON commands.
10 = OPEN local command.
11 = CLOSE local command.
12 = OPEN general comm.
13 = CLOSE general comm.
14 = OPEN priority gen. comm.
15 = CLOSE priority gen. comm.
CONTROL UNIT CONNECTION
LOCAL COMMAND INPUT: allows the LOCAL com-
mand of the motor or system. The type of command
is IMPULSIVE and the contacts are voltage free. To -
stop the engine give an inverse command respect to
the one in progress (ex: if OPEN = CLOSE). Timed
command. Mulple buons can be connected in
parallel. Recommended cable for connecon: 3x0.25
mm or 3x0.22 mm.
GENERAL COMMAND INPUT: allows the GENERAL com-
mand of the engine or system. The type of command is
IMPULSIVE and the contacts are voltage free. To stop the -
engine give an inverse command respect to the one in
course (ex: if OPEN = CLOSE). Timed command. It’s possi-
ble to connect several buons in parallel with each other.
Cable recommended for connecon: 3x0.25 mm or
3x0.22 mm.
OUTPUT CONNECTION FOR COMMAND MANAGEMENT
OF OTHER UTILITIES TO CLEAN CONTACTS: useful for ma-
naging the control of other users or equipment. the control
contacts are voltage free. Connect the wire of the MUNICI--
PALITY to the terminal 4, the wire OPENS with the terminal
5 and the wire CLOSE with the terminal 7.
Recommended cable for the connecons: 3x0.25 mm /
3x0.22 mm
This product is an integral part of the automaon and must be disposed of together with it. As for the installaon operaons,
even at the end of the life of this product, dismantling operaons must be carried out by qualied personnel. This product
consists of various types of materials: some can be recycled, others must be disposed of. Inquire about the recycling or dispo-
sal systems required by the regulaons in force in your area, for this category of product.
WARNING! Some parts of the product may contain pollung or hazardous substances which, if disper-
sed in the environment, could cause harmful eects on the environment and human health. Local re-
gulaons may provide for heavy penales for the illegal disposal of this product.
As indicated by the symbol on the side, it is forbidden to throw this product in household waste. Then
perform the "separate collecon" for disposal, according to the methods established by the regula-
ons in force in your territory, or return the product to the seller when buying a new equivalent pro-
duct.
WASTE DISPOSAL
TECHNICAL DIRECTIVES
Sases all the technical regulaons applicable to the product Within the Scope of Council Direcves 79/23/EEC:
EN55014 1:2006+A1:2009+A2:2011 EMC—Electromagnec compability:Requirements for household appliances, -
electric tools and similar apparatus. Part 1 Emission
EN55014 2:1997+A1:2001+A2:2008 EMC—Electromagnec compability:Requirements for household appliances, -
electric tools and similar apparatus. Part 1 Immunity– Product family standard.
EN6100 3 2:2006+A2:2009 EN 61000 3 3:2008: EMC—Electromagnec compability: limits for harmonic current emis-- - - -
sions and Limitaons of voltage uctuaons and icker in low voltage equipment.-
EN60335 1:2012+A11:2014 EN 60335 2 103:2005+A1:2008: Safety of householf and similar electrical appliances– Safe-- - -
ty- Part 1: General Rules
Part 2 : Parcular requirements for drives for gates, doors, Windows Motorized, etc.
Direva 2014/30/EU
Direva 2014/35/EU
MOTOR OUTPUT CONNECTION: connect the cable OPEN
of to the motor the 5 , the clamp (motor wire brown)
cable clamp CLOSE to the 7 and (motor wire black) the
COMMON clamp motor cable to the 6 . (motor wire blue)
Motor wire yellow/green will not be connected.
Power charge allowed: MAX 500 W.
Cable the 0,75 mm.recommended for connecon: 3 x