Viking VDD5450SS Handleiding

Viking Afzuigkap VDD5450SS

Lees hieronder de 📖 handleiding in het Nederlandse voor Viking VDD5450SS (12 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 78 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
USE / INSTALLATION GUIDE
5 Series
Rear Downdraft Ventilators
2
MODEL WIDTH BLOWER (purchased separately)
VDD5300/CVDD5300 30" W. VDVI600 Interior or VDVE900 Exterior
VDD5360/CVDD5360 36" W. VDVI600 Interior or VDVE900 Exterior
VDD5450/CVDD5450 45" W. VDVI600 Interior or VDVE900 Exterior, VDVE1200 Exterior
VDD5480/CVDD5480 48" W. VDVI600 Interior or VDVE900 Exterior, VDVE1200 Exterior
WARNING
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including re-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment t o prevent backdrafting. Follow the
heating equipment manufacturers guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk ofre, use only metal ductwork.
8. Do not install this product with the activating switch directly
behind a burner or element. Minimum distance between the
switch and the edge of the burner should be 4 inches.
9. Loose-fitting or hanging clothing should never be worn
when operating this appliance. They may be ignited by
burners/elements on cooktop.
10. Children should not be left alone or unattended in the area
where this appliance is in use.
11.This unit must be grounded.
12.To reduce the risk of fire or electric shock, it is
recommended that the downdraft be installed with a
dedicated circuit separate from the appliance.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
cooking flaming foods.
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out immedi-
ately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - a
violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher, and you
already know how to operate it.
B. The fire is small and contained in the area where it
started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
a Based on “Kitchen Firesafety Tips” published by NFPA.
CAUTION
1. For indoor use only.
2. For general use only. Do not use to exhaustventilating
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spra , construction dust, etc. off power y
unit.
4. Clean filters and grease-laden surfaces frequently.
5. Do not repair or replace any part of this appliance unless
specifically recommended in this manual. All other servicing
should be done by a qualified technician.
6. Please read specification label on product for further
information and requirements.
7. To reduce the risk of fire and electric shock, install this downdraft
only with blower models shown below. Other blower models
cannot be substituted. (Blowers sold separately).
Flex Blower Model VDVI600
Exterior Blower Models VDVE900, VDVE1200
INSTALLER:
Save this manual for Electrical Inspector
and Homeowner to use.
TO REDUCE THE RISK OF FIRE OR INJURY TO PERSONS -
DO NOT INSTALL WITH COOKING PRODUCTS THAT HAVE
A GRIDDLE.
3
PLANNING
DO NOT INSTALL WITH COOKING PRODUCTS THAT HAVE A
GRIDDLE
Due to its exible design, this downdraft system can be used to exhaust
airborne contaminants when cooking with a variety of gas or electric
cooking appliances - including cooktops, rangetops, slide-in ranges and
free-standing ranges.
It can be mounted in island, peninsula, or conventional wall location. The
blower (purchase separately) and electrical panel can be mounted to the
downdraft unit, inside the cabinet, or in a convenient remote location.
This unit can be easily installed following these basic steps:
Cut out the countertop opening.
Mount the unit in the cabinet.
Install the blower and electrical panel.
Connect the ductwork and electrical.
Mount the trim/door.
Install the cooking appliance.
Note: the high level of air flow of this appliance may effect the gas flame
on some types of gas cooktops. This is NORMAL and will cause no
harm, but can be corrected by lowering the speed of the blower .
ELECTRICAL SPECIFICATIONS
Model VDVI600 - Internal Flex:
120 VAC • 60 Hz • 3.0 A
Models VDVE900, VDVE1200 - Exterior
120 VAC • 60 Hz • 6.0 A (max.)
TAKE MEASUREMENTS
PLAN THE DUCTWORK
1. Refer to the cooktop installation instructions for dimensions of
cooktop, countertop cut-out, and cabinet requirements. However,
it is recommended that oversized cabinets be used for easier
installation.
2. Cooktop depth can vary greatly from one to another. This may
cause the fit of these two appliances to be rather tight.
Pay special attention to the areas of potential interference highlighted
above. A countertop with (A) a raised lip and/or (B) a backsplash may not
allow enough flat countertop for a proper installation. Note that 2-3/4" of
flat countertop is required behind cooktop and that 2-1/2" is necessary
between the back edge of the cooktop and the inside of cabinet back.
AB
C
D E
F
HOUSING
1. The downdraft blower system is designed for use with
8" round ductwork using a flex blower or 10" Round
ductwork using a remote blower. (Purchase blowers
separately.) Six (6) different discharge connections are
available - with side-to-side adjustment for accurate
alignment of ductwork:
A = 8" Round, Left Discharge out of Flex Blower
B = 8" Round, Right Discharge out of Flex Blower
C = 8" Round, Down Discharge out of Flex Blower
(Electrical Box to be mounted remotely)
D = 2" x 19¼", Left Discharge out of Housing
to Remote Blower or Flex Blower in remote
location. Use 2" x 19¼" to 8" round transition,
2" x 19¼" to 10" round transition, or 2" x 19¼"
ductwork as appropriate.
E = 2" x 19¼", Right Discharge out of Housing
to Remote Blower or Flex Blower in remote
location. Use 2" x 19¼" to 8" round transition,
2" x 19¼" to 10" round transition, or 2" x 19¼"
ductwork as appropriate.
F = 2" x 19¼", Rear Discharge out of Housing
to Remote Blower or Flex Blower in remote
location. Use 2" x 19¼" to 8" round transition,
2" x 19¼" to 10" round transition, or 2" x 19¼"
ductwork as appropriate.
2. For best performance: Choose the ducting option which
allows the shortest length of ductwork and a minimum
number of elbows and transitions. Check location of
floor joists, wall studs, electrical wiring or plumbing for
possible interference.
CONTENTS
These parts are included with your downdraft housing:
1 - Parts Bag containing:
2 - 2-in. Support Legs
2 - 4-in. Support Legs2 - Screws, 1/4-20 x .50 Hex Head
2 - Screws, 1/4-20 x .50 Hex Head
2 - Screws, #8-18 x .375 Phillipst
8 - Wood Screws, #10 x .50 Phillips Round Head
1 - Trim Kit
1 - Electrical Panel
2 - Support Brackets
2-3/4"
2-1/2"
FLEX
BLOWER *
* Remote blowers use 8" or 10" round remote discharge
plate instead ofex blower.


Product specificaties

Merk: Viking
Categorie: Afzuigkap
Model: VDD5450SS

Heb je hulp nodig?

Als je hulp nodig hebt met Viking VDD5450SS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Viking

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap

Smeg

Smeg SA940CXA Handleiding

21 November 2024
Smeg

Smeg K181X90 Handleiding

21 November 2024
Smeg

Smeg KSET66VSE2 Handleiding

21 November 2024
Smeg

Smeg KSP90XE Handleiding

21 November 2024
Smeg

Smeg KQR45NE Handleiding

21 November 2024
Smeg

Smeg KSP60HXE Handleiding

21 November 2024
Smeg

Smeg KSC90B Handleiding

21 November 2024
Smeg

Smeg KI70E Handleiding

21 November 2024
Smeg

Smeg KSC120B Handleiding

21 November 2024
Smeg

Smeg KSGT56B Handleiding

21 November 2024