Viking C-1000B Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Viking C-1000B (17 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 20 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/17
PRODUCT MANUAL
Designed, Manufactured and Supported in the USA
C O M M U N I C AT I O N & S E C U R I T Y S O L U T I O N S
Add One or Two Doorboxes to an Existing
Phone Line and Provide CCTV Camera Control
Features
The C-1000B allows single line phones or
phone systems to share a phone line with
one or two Viking doorboxes or paging am-
plifiers. The C-1000B provides two Touch
Tone controlled relays to operate door strikes
or gate openers and provides doorbox trig-
gered CCTV camera switching.
Viking doorboxes and paging amplifiers can
be used on single line, residential or home
office applications as well as on fully loaded
systems, because they are no longer limited
to installation on unused trunk ports.
Power: 120V AC/13.8V AC 1.25A, UL listed adapter pro-
vided
Dimensions: 133mm x 104mm x 44mm (5.25" x 4.1" x
1.75")
Shipping Weight: 0.9 kg (2 lb)
Environmental: 0° C to 32° C (32° F to 90° F) with 5% to
95% non-condensing humidity
Door Strike Relay Contacts: 5A @ 30V DC/250V AC
maximum
CCTV/Auxiliary Relay Contacts: .5A @ 125V AC, 1A @
30V DC
Pulse Dialing Detection: 10 pps
Talk Battery: 28V DC
Maximum Doorbox Power Supply Length: 100 ft, 24
awg wire
Connections: (1) 7 position terminal block and (1) 19 po-
sition terminal block
C-1000B
Door Entry and CCTV
Camera Controller
August 13, 2014
Applications
Specifications
www.vikingelectronics.com
Information: (715) 386-8861
VIKING
Allows two doorboxes or pagingViking Viking
amplifiers to share a single telephone line with
a residential or business telephone system
• Doorbox triggered CCTV camera switching
• Custom ringing mode allows you to distinguish
doobox calls from C.O. calls
• Compatible with up to two of the following
Viking W-1000 W-2000Adoorbox models: , , or
W-3000. Alternatively, the Analog PABX/KSU
station mode allows compatibility with a single
Viking E-10A E-20B E-30handsfree phone ( , , ,
K-1700-3 1600A Seriesor )
• Compatible with Viking’s Single Line Paging
Controller, Model SLP-1
• Call waiting tones indicate which doorbox is
calling and distinguish a doorbox call from a
C.O. line call
• Calls can be placed on hold when visitors call
from the doorbox or when paging
• Provides two Touch Tone controlled N.O. or
N.C. dry contact closures (5 amp rating) for
door strikes or gate openers
• Keyless entry/postal lock input
• Built-in talk battery for “No C.O. Line” applica-
tions
Auxiliary contact output for doorbells, lights,
etc.
Add one or two Doorboxes to your home orViking
office phones
• Switch between two CCTV cameras automati-
cally when either doorbox is activated
Add a Single Line Paging ControllerViking SLP-1
to provide paging, intercom, loud ringing, door
chime and music on hold features
• Provide commercial or residential security via two-
way handsfree communication from a door or gate
• Use as a line concentrator (one fax machine or an-
swering machine can answer three lines)
EARTH
GND
C.O. LINE
INPUT
OUT TO
PHONES
KEYLESS
C.C. INPUT
DOOR
BOX 1
DOORBOX
13VAC PWR
DOOR
BOX 2
N.O. COM N.C.
DOOR STRIKE 1
SIG GND
VIDEO 1 IN
SIG GND
VIDEO 2 IN
SIG GND
VIDEO OUT
N.O. COM N.C.
DOOR STRIKE 2
TALK BATTERY
OFF ON
C
LED1
C
LED2
C
LED3
ON
1 2 3
COM N.O. N.C. - - - - AUX.
CONTACT
OUTPUT
or
Standard
Analog Phones
Unused Trunk Input
of PABX/KSU (set
"Talk Battery"
switch to ON)
Talk Battery Switch
OFF ON
C.O. Line
Earth Ground
(above) Doorbox 2:
Back view of the W-2000A
shown, not included (DOD# 170)
**CCTV Camera 1
(not included)
**CCTV Camera 2
(not included)
**TV, Video Monitor, VCR Recorder
or RF Modulator (not included)
* Power
* Power
ON
1 2 3
DIP Switches
ON
OFF
VIKING©
VIKING
ELECTRONICS
HUDSON, WI 54016
DOOR ENTRY / CCTV VIDEO
CONTROLLER
POWER 13.8V AC
MODEL C-1000B
PHONE LINE
INPUT
EARTH
GND
21 3 4 5 14 15 16
LINE OUT
TO PHONES
6 7
KEYLESS CONTACT
CLOSURE INPUT
DOORBOX 1
DOORBOX 2
8 9 10 11
DOORBOX
PWR OUTPUT
12 13
DOOR
STRIKE 1
N.O.
COM
N.C.
17 18 19
DOOR
STRIKE 2
N.O.
COM
N.C.
Ground
Signal
Ground
Signal
Signal
Ground
ON
1 2 3
ON
1 2
ON
1 2 3
ON
1 2
5A @ 30V DC
250V AC
maximum
(not included)
Doorstrike /
Magnetic Lock 2
Door
5A @ 30V DC
250V AC
maximum
(not included)
Doorstrike /
Magnetic Lock 1
Door
(left) Doorbox 1:
Back view of the W-1000
shown, not included (DOD# 170)
Note: Over 100ft power
runs require separate
doorbox power adapters.
* Note: Use the power supply
recommended and/or supplied
by the camera manufacturer.
Features Overview
Installation
EARTH
GND
C.O. LINE
INPUT
OUT TO
PHONES
KEYLESS
C.C. INPUT
DOOR
BOX 1
DOORBOX
13VAC PWR
DOOR
BOX 2
N.O. COM N.C.
DOOR STRIKE 1
SIG GND
VIDEO 1 IN
SIG GND
VIDEO 2 IN
SIG GND
VIDEO OUT
N.O. COM N.C.
DOOR STRIKE 2
TALK BATTERY
OFF ON
PWR
ON
1 2 3
COM N.O. N.C. - - - - AUX.
CONTACT
OUTPUT
* Earth Ground
C.O./Phone Line Input
Out to Telephones
Keyless Entry/Postal Lock
Contact Closure Input
Door Box 1 Line Input
Door Strike 1
Contact Output
Door Box 2 Line Input
Doorbox 13V AC
Power Output
Door Strike 2
Contact Output
N.C.
COM
N.O.
N.C.
COM
N.O.
D.S.1 D.S.2
CCTV
Video
1 Input
CCTV Video
2 Input
CCTV Video
Output
Signal
Ground
Signal
Ground
Signal
Ground
N.C.
N.O.
COM
Auxiliary
Contact Output Power LED: Lights
while unit is powered.
Door Strike 1 LED:
Lights while doorstrike
1 relay is activated.
Door Strike 2 LED:
Lights while doorstrike
2 relay is activated.
Power Input
(13.8VAC @ 1.25A
adapter included)
VIKING©
VIKING
ELECTRONICS
HUDSON, WI 54016
DOOR ENTRY / CCTV VIDEO
CONTROLLER
POWER 13.8V AC
MODEL C-1000B
PHONE LINE
INPUT
EARTH
GND
21 3 4 5 14 15 16
LINE OUT
TO PHONES
6 7
KEYLESS CONTACT
CLOSURE INPUT
DOORBOX 1
DOORBOX 2
8 9 10 11
DOORBOX
PWR OUTPUT
12 13
DOOR
STRIKE 1
N.O.
COM
N.C.
17 18 19
DOOR
STRIKE 2
N.O.
COM
N.C.
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC
outlet and the telephone line. It is recommended that a surge protector be installed to protect against such surges.
2
A. One or Two Doorboxes Sharing a Phone Line and Controlling Two Optional Cameras
See , section .Operation A
** Note: The C-1000B must be pro-
grammed with (
Q
8) to control cameras.
In the CCTV video control mode (
Q
8),
Auxiliary Contact Mode is disabled.
* Note: To increase surge protection, fasten a wire from the screw terminal to Earth Ground (grounding rod, water pipe, etc.)
VIKING
©
VIKING
ELECTRONICS
HUDSON, WI 54016
STAND ALONE
DOOR CONTROLLER
ENTRY SYSTEM
POWER 12V DC
MODEL ES-1
1
POWER
PROGRAM
PHONE
LOG
BUS
2 3 4 5
GANG
PROG
6789
WIEGAND
DEVICE
10 11
DOOR
STRIKE
N.O.
2
1
L
H
COM
N.C.
BLK
RED
GRN
WHT
Keyed Momentary Switch/
Postal Lock with Limit
Switch (not included) * Viking PRX-1
Proximity Card Reader
(not included, see DOD# 221)
* Viking PRX-4
Keypad
(not included,
see DOD# 199)
and/
or
and/or
ON
1 2 3
DIP Switches
ON
OFF
EARTH
GND C.O. LINE
INPUT OUT TO
PHONES KEYLESS
C.C. INPUT DOOR
BOX 1 DOORBOX
13VAC PWR DOOR
BOX 2 N.O. COM N.C.
DOOR STRIKE 1
SIG GND
VIDEO 1 IN SIG GND
VIDEO 2 IN SIG GND
VIDEO OUT
N.O. COM N.C.
DOOR STRIKE 2
TALK BATTERY
OFF ON
C
LED1
C
LED2
C
LED3
ON
1 2 3
COM N.O. N.C. - - - - AUX.
CONTACT
OUTPUT
VIKING ©
VIKING
ELECTRONICS
HUDSON, WI 54016
DOOR ENTRY / CCTV VIDEO
CONTROLLER
POWER 13.8V AC
MODEL C-1000B
PHONE LINE
INPUT
EARTH
GND
21 3 4 5 14 15 16
LINE OUT
TO PHONES
6 7
KEYLESS CONTACT
CLOSURE INPUT
DOORBOX 1
DOORBOX 2
8 9 10 11
DOORBOX
PWR OUTPUT
12 13
DOOR
STRIKE 1
N.O.
COM
N.C.
17 18 19
DOOR
STRIKE 2
N.O.
COM
N.C.
Viking ES-1
(not included,
DOD# 193)
3
B. Provide Paging, Doorbox, and Doorstrike Control with Unique Front and Back Door Chimes
Note: To provide unique front and back door chimes, the must be programmed to enable the “AuxiliaryC-1000B
Contact Mode” (
Q
7) and have the auxiliary contact programmed for custom ring cadence (12#03). Doorbox ringing
can also be disabled by placing the in the “Doorbell Mode” (C-1000B
Q
1). See Quick Programming Features,
page 6. The CCTV Video Control Mode can C-1000B NOTbe used in conjunction with unique front and back
door chimes. The caller’s music on hold is limited to 5 seconds while the home owner is communicating with a
doorbox.
VIKING©
VIKING
ELECTRONICS
HUDSON, WI 54016
DOOR ENTRY / CCTV VIDEO
CONTROLLER
POWER 13.8V AC
MODEL C-1000B
PHONE LINE
INPUT
EARTH
GND
21 3 4 5 14 15 16
LINE OUT
TO PHONES
6 7
KEYLESS CONTACT
CLOSURE INPUT
DOORBOX 1
DOORBOX 2
8 9 10 11
DOORBOX
PWR OUTPUT
12 13
DOOR
STRIKE 1
N.O.
COM
N.C.
17 18 19
DOOR
STRIKE 2
N.O.
COM
N.C.
C.O. / Phone Line
EARTH
GND C.O. LINE
INPUT OUT TO
PHONES KEYLESS
C.C. INPUT DOOR
BOX 1 DOORBOX
13VAC PWR DOOR
BOX 2 N.O. COM N.C.
DOOR STRIKE 1
SIG GND
VIDEO 1 IN
SIG GND
VIDEO 2 IN
SIG GND
VIDEO OUT
N.O. COM N.C.
DOOR STRIKE 2
TALK BATTERY
OFF ON
C
LED1
C
LED2
C
LED3
ON
1 2 3
COM N.O. N.C. - - - - AUX.
CONTACT
OUTPUT
Standard
Analog Phone
To Doorstrike/
Magnetic Lock 2
To Doorstrike/
Magnetic Lock 1
To Additional
Standard
Analog Phones
To Viking Doorbox 1
(Front Door)
To Viking Doorbox 2
(Back Door)
DIP Switch 2
must be ON
ON
OFF
1 2 3
ON
Up to (3) 8 Ohm
Speakers or Paging
Horns (optional)
Page Input
Multi-Zone
Controller/Amplifier
Page Trigger
(Control) Input
+
-
DOOR BELL
SW. INPUT
LOUD RING
ENABLE
- +
I.O. COM.
ON
1 2 3
PWR PAGE MUTE
PAGE TRIG. OUT
C.O. LINE
INPUT
OUT TO
PHONES
- SPKR +
OUTPUT
L LR R
- +
VIKING©
VIKING
ELECTRONICS
HUDSON, WI 54016
SINGLE LINE
PAGING CONTROLLER
POWER 13.8 VAC
MODEL SLP-1
PREAMP
VOLUME
2 WATT
AMP GAIN
MIN MAX MIN MAX
MUSIC
ON
HOLD
INPUT
AUDIO
INPUT
L R
AUDIO
OUTPUT
L R
Optional 12VDC
page trigger output
(20mA maximum)
- +
13.8V AC
Adapter
(included)
120V AC
13.8V AC
Adapter
(included)
120V AC
Model SLP-1
not included
(DOD# 478)
The C-1000B can also be used without a C.O.
line. This is ideal for connecting the C-1000B to
an unused trunk/line input of your phone system
or connecting to phones used only for doorbox
communication.
EARTH
GND C.O. LINE
INPUT OUT TO
PHONES KEYLESS
C.C. INPUT DOOR
BOX 1 DOORBOX
13VAC PWR DOOR
BOX 2 N.O. COM N.C.
DOOR STRIKE 1
SIG GND
VIDEO 1 IN
SIG GND
VIDEO 2 IN
SIG GND
VIDEO OUT
N.O. COM N.C.
DOOR STRIKE 2
TALK BATTERY
OFF ON
C
LED1
C
LED2
C
LED3
ON
1 2 3
COM N.O. N.C. - - - - AUX.
CONTACT
OUTPUT
or
Standard
Analog
Phones
Unused
Trunk Input
of PABX/KSU
OFF ON
ON
1 2 3
DIP Switches
ON
OFF
VIKING ©
VIKING
ELECTRONICS
HUDSON, WI 54016
DOOR ENTRY / CCTV VIDEO
CONTROLLER
POWER 13.8V AC
MODEL C-1000B
PHONE LINE
INPUT
EARTH
GND
21 3 4 5 14 15 16
LINE OUT
TO PHONES
6 7
KEYLESS CONTACT
CLOSURE INPUT
DOORBOX 1
DOORBOX 2
8 9 10 11
DOORBOX
PWR OUTPUT
12 13
DOOR
STRIKE 1
N.O.
COM
N.C.
17 18 19
DOOR
STRIKE 2
N.O.
COM
N.C.
Talk Battery Switch
C. Using a C-1000B without a C.O. Line
Step 1.
Connect the power, required doorboxes,
and doorstrike outputs (if required) as
shown in section A.
Step 2.
Connect an analog phone or unused
PABX/KSU trunk port to terminals 4& 5,
” on the .LINE OUT TO PHONES C-1000B
Step 3. Be sure the Talk Battery Switchis in the
ON position.
D. Using the C-1000B with Keyless Entry, Proximity Card Reader or a Postal Lock Switch
Step 1.
Connect a device
that can provide a
momentary contact
closure, such as the
Viking withES-1
PRX-1 Card Reader
or Keypad,PRX-4
keyed switch, postal
lock with limit
switch,etc. to termi-
nals & , “6 7 KEY-
LESS CONTACT
CLOSURE INPUT”.
Step 2.
Connect doorboxes
and doorstrike out-
puts (if required) as
shown in section .A
Step 3.
See sec-Operation
tion E. Keyless
Entry/Postal Lock.* Note: PRX-2 Also available, not shown: Viking Card Reader/Keypad
(DOD# 219) and Viking Card Reader (DOD# 228)PRX-3


Product specificaties

Merk: Viking
Categorie: Niet gecategoriseerd
Model: C-1000B
Gewicht: 900 g
Breedte: 133 mm
Diepte: 104 mm
Hoogte: 44 mm
Kastontwerp: Behuizing
Maximum aantal deuren: 2 deur(en)
Bedrijfstemperatuur (T-T): 0 - 32 °C
Relatieve vochtigheid in bedrijf (V-V): 5 - 95 procent
Schakelbare stroom: 1.25 A
Alarm output stroom: 5 A

Heb je hulp nodig?

Als je hulp nodig hebt met Viking C-1000B stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Viking

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd