Vertex Standard VX-350 Series Handleiding
Vertex Standard
Radio communicatie
VX-350 Series
Lees hieronder de 📖 handleiding in het Nederlandse voor Vertex Standard VX-350 Series (2 pagina's) in de categorie Radio communicatie. Deze handleiding was nuttig voor 59 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/2
VX-350 Series
Operating Manual
Controls & Connectors
Display Icons & Indicators (LCD Version)
To transmit, monitor the channel and make sure it is clear.
To transmit, press and hold in the PTT switch. Speak
into the microphone area of the front panel grille
(lower right-hand corner) in a normal voice level.
To return to the Receive mode, release the PTT
switch.
Do not transmit the radio without an antenna con-
nected.
If a Speaker/Microphone is available, remove the plastic cap and its two mount-
ing screws from the right side of the transceiver, then insert the plug from the
Speaker/Microphone into the MIC/SP jack; secure the plug using the screws
supplied with the Speaker/Microphone. Hold the speaker grille up next to your
ear while receiving. To transmit, press the PTT switch on the Speaker/Micro-
phone, just as you would on the main transceiver’s body.
Note:Save the original plastic cap and its mounting screws. They should
be re-installed when not using the Speaker/Microphone.
OperationBefore You Begin
BATTERY PACK INSTALLATION AND REMOVAL
To install the battery, hold the transceiver with your left
hand, so your palm is over the speaker and your
thumb is on the top of the belt clip. In-
sert the battery pack into the bat-
tery compartment on the back
of the radio while tilting the
Belt Clip outward, then push
the bottom side of the battery
pack until the battery pack
locks with the Battery Pack
Latch.
To remove the battery, turn the radio off and remove any protective cases. Slide
the Battery Pack Latch on the bottom of the radio, then slide the battery down-
ward and out from the radio while holding the Belt Clip.
Caution!
Do not attempt to open any of the rechargeable Lithium-Ion packs, as they
could explode if accidentally short-circuited.
LOW BATTERY INDICATION
As the battery discharges during use, the voltage gradually becomes lower. When
the battery voltage becomes to low, substitute a freshly charged battery and re-
charge the depleted pack. When the battery voltage is low, the LED indicator on the
top of the radio will blink red and “Battery Indicator” on the LCD will blink on the
LCD version. Furthermore, if your Dealer sets the “Low Battery Alert” feature into
the transceiver, an alert beeper will sound when the battery voltage is low.
PRELIMINARY STEPS
Install a charged battery pack onto the transceiver, as described previously.
Screw the supplied antenna onto the Antenna jack. Never attempt to operate this
transceiver without an antenna connected.
If you have a Speaker/Microphone, we recommend that it not be connected
until you are familiar with the basic operation of the VX-350.
OPERATION QUICK START
Turn the top panel’s VOL/PWR knob clockwise to
turn on the radio on.
Turn the top panel’s CH selector knob to choose the
desired operating channel.
Rotate the VOL/PWR knob to set the volume level.
If no signal is present, press and hold in the Pro-
grammable key assigned to “SQL OFF” for more
than one second; background noise will now be
heard, and you may use this to set the VOL/PWR
knob for the desired audio level.
Press and hold in the Programmable key assigned
to “SQL OFF” for more than one second (or press
the key twice) to quiet the noise and resume normal
(quiet) monitoring.
Microphone
Speaker
MIC/SP Jack
(
External Mic/Earphone
)
VOL/PWR Knob
CH (Channel) Selector
Side 1 Switch
Push To Talk
(PTT) Switch
Antenna
LED Indicator
LCD (LCD VERSION)4 Key (LCD VERSION)
Battery Pack Latch
Side 2 Switch
Glows Green
Blinking Green
Glows Red
Blinking Red
Yellow
Monitor on (or Side 1, or 2 switch is activated: Non-LCD version)
Busy Channel (or SQL off)
Transmitting
Battery Voltage is Low
Receiving a Selective Call
SAFETY TRANING INFORMATION
This Radio has been tested and complies with the Federal Communications
Commission (FCC) RF exposure limits for Occupational Use/Controlled ex-
posure environment. In addition, it complies with the following Standards and
Guidelines:
FCC 96-326, Guidelines for Evaluating the Environmental Effects of Ra-
dio-Frequency Radiation.
FCC OET Bulletin 65 Edition 97-01 (1997) Supplement C, Evaluating
Compliance with FCC Guidelines for Human Exposure to Radio Frequency
Electromagnetic Fields.
ANSI/IEEE C95.1-1992, IEEE Standard for Safety Levels with Respect to
Human Exposure to Radio Frequency Electromagnetic Fields, 3kHz to 300
GHz.
ANSI/IEEE C95.3-1992, IEEE Recommended Practice for the Measure-
ment of Potentially Hazardous Electromagnetic Fields-RF and Microwave.
WARNING: This radio generates RF electromagnetic energy during
transmit mode. This radio is designed for and classified as Occupa-
tional Use Only, meaning it must be used only during the course of employ-
ment by individuals aware of the hazards, and the ways to minimize such haz-
ards. This radio is not intended for use by the General Population in an uncon-
trolled environment.
CAUTION: To ensure that your expose to RF electromagnetic energy
is within the FCC allowable limits for occupational use, always adhere
to the following guidelines:
Please read this manual carefully to become familiar with the features
of this transceiver.
Do not transmit the radio without an antenna connected.
This radio is NOT approved for use by the general population in an
uncontrolled environment. This radio is restricted to occupational use,
work related operations only where the radio operator must have the
knowledge to control its RF exposure conditions.
When transmitting, hold the radio in a vertical position with its micro-
phone 1 to 2 inches (2.5 to 5 cm) away from your mouth and keep the
antenna at least 1 inch (2.5cm) away from your head and body.
The radio must be used with a maximum operating duty cycle not
exceeding 50 %, in typical Push-to-Talk (PTT) configurations. DO NOT
transmit for more than 50 % of total radio use time (50 % duty cycle).
Transmitting more than 50 % of the time can cause FCC RF exposure
compliance requirements to be exceeded.
To keep the Body Worn configuration with the Vertex Standard CLIP-
18 belt-clip, reduce the maximum operating duty cycle still more.
The radio is transmitting when the red LED on the top of the radio is
illuminated. You can cause the radio to transmit by pressing the PTT
button.
When operate the radio with the Vertex Standard CLIP-18 belt-clip,
make the transmission time as short as possible, to keep the Body Worn
configuration.
Always use the FNB-V96LIA or FNB-V130LI-UNI Lithium-Ion Bat-
tery.
Perform the battery charging where the ambient temperature range
+10 °C to +40 °C. Charge out of this range could cause damage to the
battery pack.
Battery Pack shall not be exposed to excessive heat such as sunshine,
fire or the like.
Always use Vertex Standard authorized accessories.
Vertex Standard shall not be liable for any damage or accidents such
as fire, leakage or explosion of batteries, etc., caused by the malfunc-
tion of non-Vertex Standard accessories.
The information listed above provides the user with the information needed to
make him or her aware of RF exposure, and what to do to assure that this radio
operates with the FCC RF exposure limits of this radio.
Electromagnetic Interference/Compatibility
During transmissions, this radio generates RF energy that can possibly
cause interference with other devices or systems. To avoid such interfer-
ence, turn off the radio in areas where signs are posted to do so.
Do not operate the transmitter in areas that are sensitive to electromag-
netic radiation such as hospitals, health care facilities, aircraft, and blast-
ing sites.
FCC License Information
This radio operates on communications frequencies which are subject to
FCC (Federal Communications Commission) Rules and Regulations. FCC
Rules require that all operators using Private Land Mobile radio frequen-
cies obtain a radio license before operating their equipment.
Tilt the Belt Clip
Insert the Battery Pack
Push the bottom side
of the battery pack
Accessories & Options
FNB-V96LIA 7.4 V 2300 mAh Li-Ion Battery Pack
FNB-V130LI-UNI 7.4 V 2300 mAh Li-Ion Battery Pack
VAC-300 Desktop Rapid Charger Set (CD-34+PA42, for FNB-V96LI)
VAC-6300 6-unit Multi Charger (for FNB-V96LI)
CD-58 Desktop Charger (for FNB-V130LI-UNI)
PA-55 AC Adapter (for CD-58)
VAC-6058 6-unit Multi Charger (for FNB-V130LI-UNI)
MH-37A4B Earpiece/Microphone
MH-45B4B Speaker/Microphone
MH-360S Speaker/Microphone
MH-450S Speaker/Microphone
VCM-2 Vehicle Charger Mount Adapter (for VAC-300)
DCM-1 Desktop Charger Mount Adapter (for VAC-300)
FVP-25 Encryption/DTMF pager Unit
FVP-35 Rolling Code Encryption Unit
FVP-36 Voice Inversion Encryption Unit
VME-100 MDC1200®/GE-Star® ANI Encoder Unit
ATU-6A Rubber Antenna 400-430 MHz
ATU-6B Rubber Antenna 420-450 MHz
ATU-6C Rubber Antenna 440-470 MHz
ATU-6D Rubber Antenna 450-485 MHz
ATU-6F Rubber Antenna 485-520 MHz
ATV-6XL Rubber Antenna 134-174 MHz (Untuned)
ATV-8A Rubber Antenna 134-151 MHz
ATV-8B Rubber Antenna 150-163 MHz
ATV-8C Rubber Antenna 161-174 MHz
CLIP-17E Swivel Belt Clip
CLIP-18 Belt Clip
LCC-350 Leather Case
CE86 Programming Software
FIF-12 USB Programming Interface
CT-27 Radio to Radio Programming Cable
CT-106 PC Programming Cable (for FIF-12)
Operating Temperature Range
Operation: USA/EXP versions: –30 °C to +60 °C (–22 °F to +140 °F)
European version: –25 °C to +55 °C (–13 °F to +131 °F)
Battery Charging: +10 °C to +40 °C (+50 °F to +104 °F)
IMPORTANT NOTICE
Please follow these cautions to prevent hearing damage:
Always adjust the audio level of the transceiver to the minimum before
connecting the Earpiece/Headset to the transceiver.
Use the Earpiece/Headset at as low a volume as possible for existing
conditions.
Slowly adjust the VOL/PWR knob when increasing the audio level.
“Talk-Around” is enabled
“Dual Watch” is activated
“Call” Indicator
Receiver Monitor
Low Power Transmit Mode
8 Character Alpha-numeric Display
“Encryption” is enabled
: This channel is in the “Scan” List
: “Priority Scan” is activated
Priority Channel indication
Battery Indicator
RSSI Indicator
NOTICE !
There are no owner-serviceable parts inside the transceiver. All service
jobs must be referred to an authorized VERTEX STANDARD Service
Representative. Consult your Authorized VERTEX STANDARD Dealer
for installation of optional accessories.
DISPOSAL OF YOUR ELECTRONIC AND
ELECTRIC EQUIPMENT
Products with the symbol (crossed-out wheeled bin) cannot be disposed as
household waste.
Electronic and Electric Equipment should be recycled at a
facility capable of handling these items and their waste
byproducts.
In EU countries, please contact your local equipment sup-
plier representative or service center for information about
the waste collection system in your country.
IMPORTANT NOTICE FOR NORTH A MERICAN USERS
REGARDING 406 MHZ GUARD BAND
The U.S. Coast Guard and National Oceanographic and Atmospheric Ad-
ministration have requested the cooperation of the U.S. Federal Communi-
cations Commission in preserving the integrity of the protected frequency
range 406.0 to 406.1 MHz, which is reserved for use by distress beacons.
Do not attempt to program this apparatus, under any circumstances, for
operation in the frequency range 406.0 - 406.1 MHz if the apparatus is to
be used in or near North America.
Warning - Frequency band 406 - 406.1 MHz is reserved for use ONLY
as a distress beacon by the US Coast Guard and NOAA. Under no
circumstance should this frequency band be part of the
preprogrammed operating frequencies of this radio.
This device complies with Part 15 of the FCC rules. Operation is subject to
the condition that this device does not cause harmful interference.
EC065N207
Code Set
Press the assigned Programmable key to change the encode digits for 5-tone
operation. To change a specific digit, select the desired digit using the [A] key, then
change the number using the [B]/[C] keys, and store the number using the [D] key.
Speed Dial
Your Dealer may have pre-programmed Auto-Dial telephone number memories (up
to five memories) into your radio.
To dial a number, press (or Press and hold) the assigned Programmable key to
toggle the pre-programmed Auto-Dial telephone number memory, then press the
PTT switch. The DTMF tones sent during the dialing sequence will be heard in the
speaker.
Emergency
The VX-350 series includes an “Emergency” feature, which may be useful, if you
have someone monitoring on the same frequency as your transceiver’s channel. For
further details contact your VERTEX STANDARD dealer.
Option Switch 1, Option Switch 2
When the optional unit is installed, these functions have various uses.
For further details, contact your VERTEX STANDARD dealer.
Lock
Press (or Press and hold) the assigned Programmable key to lock the VX-350’s
knob, Programmable keys, and PTT switch. The precise lockout configuration is
programmed by your VERTEX STANDARD dealer.
Follow-Me Scan
“Follow-Me” Scan feature checks a User-assigned Priority Channel regularly as
you scan the other channels. Thus, if only Channels 1, 3, and 5 (of the 8 available
channels) are designated for “Scanning,” the user may nonetheless any channel as
the “User-assigned” Priority Channel via the “Follow-Me” feature.
Press the assigned Programmable key to activate “Follow-Me” scanning, then
turn the CH selector knob to the channel which you want to designate as the “User-
Assigned Priority Channel”. When the scanner stops on an “active” channel, the
User-assigned Priority Channel will automatically be checked every few seconds.
SQL Set
You can manually adjust the squelch level using this function:
Press the assigned Programmable key. A tone will sound, and the current
squelch level will appear on the display.
Press the [Side 1]/[Side 2] key to select the desired squelch level.
Two seconds after releasing the [Side 1]/[Side 2] key, the display will revert
to the normal channel indication.
Lone Worker
Press and hold the assigned Programmable key to toggle the Lone Worker fea-
ture “ON” and “OFF.”
The Lone Worker feature will emit an audible alarm for 30 seconds at one second
intervals when the Lone Worker Timer has expired. If the user does not reset the
timer by pressing the PTT switch, the radio switches to the Emergency mode.
TA Scan
Press the assigned programmable key to toggle the TA (Talk Around) scan feature
“On” and “Off.”
While TA scan is proceeding, the VX-350 will search both the transmit and receive
frequencies (the “ ” icon will blink on the LCD versions). When a signal is en-
countered on the receive frequency, the VX-350 will pause until the signal disap-
pears (“ ” icon will appear but not blink). When a signal is encountered on the
transmit frequency, the VX-350 will check for activity on the receive frequency
every few seconds (interval programmed by your Dealer).
SQL Off
Press (or Press and hold) the assigned Programmable key to disable the Noise
and Tone squelch. Again press (or Press and hold) the assigned Programmable
key to resume normal (quiet) Noise and Tone squelch action.
Scan Set
Press (or press and hold) the assigned Programmable key to delete the Current
Memory Channel from the Scanning List. When you delete a channel from the
Scanning List, a ringing beeper will sound, and “ ” icon will disappear from the
LCD (LCD version). To restore a particular channel to your Scanning List, press (or
press and hold) the assigned Programmable key again; a ringing beeper will sound,
and “ ” icon will appear on the LCD (LCD version).
Whisper
Press (or Press and hold) the assigned Programmable key to increase the micro-
phone gain; thus you can speak in a low voice (whisper) temporarily. Again press
(or Press and hold) the assigned Programmable key to resume normal micro-
phone gain.
Beep Off
Press (or Press and hold) the assigned Programmable key to disable the radio
beeps temporarily. Again press (or Press and hold) the assigned Programmable
key to enable the radio beeps.
Mon (Monitor)
Press (or Press and hold) the assigned Programmable key momentarily to disable
the Tone squelch.
Lamp
Press (or Press and hold) the assigned Programmable key to illuminate the LCD
for five seconds (LCD version).
Scan
The Scanning feature is used to monitor multiple channels programmed into the
transceiver. While scanning, the radio will check each channel for the presence of a
signal, and will stop on a channel if a signal is present.
To activate scanning:
Press (or Press and hold) the assigned Programmable key.
The scanner will search the channels, looking for active ones; it will pause each
time it finds a channel on which someone is speaking.
To stop scanning:
Press (or Press and hold) the assigned Programmable key.
Operation will revert to the channel to which the CH knob is set.
DW (Dual Watch)
The Dual Watch feature is similar to the Scan feature, except that only two channels
are monitored: the current operating channel, and the “Priority” channel.
To activate Dual Watch:
Press (or Press and hold) the assigned Programmable key.
The scanner will search the two channels; it will pause each time it finds a
channel on which someone is speaking.
To stop Dual Watch:
Press (or Press and hold) the assigned Programmable key.
Operation will revert to the channel to which the CH knob is set.
Low Power
Press (or Press and hold) the assigned Programmable key to set the radio’s trans-
mitter to the “Low Power” mode, thus extending battery life. Press (or Press and
hold) the assigned Programmable key again to return to “High Power” operation
when in difficult terrain.
When the radio’s transmitter is set to “Low Power” mode, the “L” icon will be
indicated on the LCD (LCD version).
TA (Talk Around)
Press (or Press and hold) the assigned Programmable key to activate the Talk
Around feature when you are operating on duplex channel systems (separate re-
ceive and transmit frequencies, utilizing a “repeater” station). The Talk Around fea-
ture allows you to bypass the repeater station and talk directly to a station that is
nearby. This feature has no effect when you are operating on “Simplex” channels,
where the receive and transmit frequencies are already the same.
When the “TA” function is activated, the “ ” icon will be indicated on the LCD
(LCD version).
TX Save Disable
Press (or Press and hold) the assigned Programmable key to disable the Transmit
Battery Saver, if you are operating in a location where high power is almost always
needed.
The Transmit Battery Saver helps extend battery life by reducing transmit power
when a very strong signal from an apparently nearby station is being received. Un-
der some circumstances, though, your hand-held radio may not be heard well at the
other end of the communication path, and high power may be necessary at all times.
Encryption
When the Voice Scrambler feature is enabled, pressing the assigned Program-
mable key of the “Encryption” toggles the Scrambler “on” and “off.”
Channel Up
Press (or Press and hold) the assigned Programmable key to switch to a higher
operating channel number.
Channel Down
Press (or Press and hold) the assigned Programmable key to switch to a lower
operating channel number.
Call, Reset
Press (or Press and hold) the assigned Programmable key to silence the receiver
and reset for another call, when a communication is finished.
Call 2, Call 3
Press (or Press and hold) the assigned Programmable key to send a 5-Tone se-
quential tone group which is pre-defined.
Code Up, Code Down
Press (or Press and hold) the assigned Programmable key to switch to a higher
(or lower) paging code number for the 5-Tone Paging System.
Description of Operating FunctionsKey Functions
All versions of the VX-350 provide [Side 1] and [Side 2] keys. The LCD version
of the VX-350 provide [A], [B], [C], and [D] function keys. These Program-
mable keys functions can be customized (set to other functions), via program-
ming by your VERTEX STANDARD dealer, to meet your communications/net-
work requirements. Some features may require the purchase and installation of op-
tional internal accessories. The possible Programmable key features are illus-
trated below, and their functions are explained in the next chapter. For further de-
tails, contact your VERTEX STANDARD dealer.
For future reference, check the box next to each function that has been assigned to
the Programmable key on your particular radio, and keep it handy.
ARTS (Auto Range Transpond System)
This system is designed to inform you when you and another ARTS-equipped sta-
tion are within communication range.
During ARTS operation, your radio automatically transmits for about 1 second
every 55 seconds (or 25 seconds: Dealer Programmed) in an attempt to shake hands
with the other station.
If you are out of range for more than two minutes, your radio senses that no signal
has been received, a ringing beeper will sound, and “OUT RANGE” will appear on
the LCD (on the LCD version). If you subsequently move back into range, as soon
as the other station transmits, your beeper will sound and “IN RANGE” will appear
on the LCD (on the LCD version).
DTMF Paging System
This system allows paging and selective calling, using DTMF tone sequences.
When your radio is paged by a station bearing a tone sequence which matches
yours, your radio’s squelch will open and the alert will sound. On the LCD version,
the three-digit code of the station which paged you will be displayed on your radio’s
LCD.
1: LCD Version only
2: Requires FVP-25, FVP-35, or FVP-36 Encryption Unit.
3: FVP-35 only
FUNCTION
None
Mon (Monitor)
Lamp1
Scan
DW (Dual Watch)
Low Power
TA (Talk Around)
TX Save Disable
Encryption2
CH Up1
CH Down1
Call
Reset
Call 2
Call 3
Code Up1
Code Down1
Code Set1
Speed Dial1
Emergency
Option Switch 13
Option Switch 23
Lock
FM-Scan
SQL Set1
Lone Worker
TA Scan
SQL Off
Scan Set
Whisper
Beep Off
[D]
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
-- /--
/
/
/
/
/
-- /--
/
/
/
/
/
[Side 2]
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
-- /--
/
/
/
/
/
-- /--
/
/
/
/
/
[Side 1]
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
-- /--
/
/
/
/
/
-- /--
/
/
/
/
/
[C]
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
-- /--
/
/
/
/
/
-- /--
/
/
/
/
/
[B]
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
--/--
/
/
/
/
/
--/--
/
/
/
/
/
[A]
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
--/--
/
/
/
/
/
--/--
/
/
/
/
/
PROGRAMMABLE KEY (PRESS / PRESS AND HOLD)
ATTENTION IN CASE OF USE
This transceiver works on frequencies which are not generally permitted.
For frequency allocation, apply for
a licence at your local spectrum
management authority.
For actual usage contact your
dealer or sales shop in order to get
your transceiver adjusted to the al-
located frequency range.
AUT BEL BGR CYP CZE DEU
DNK ESP EST FIN FRA GBR
GRC HUN IRL ITA LTU LUX
LVA MLT NLD POL PRT ROU
SVK SVN SWE CHE ISL LIE
NOR
List of the practicable area
Vertex Standard LMR, Inc.
Copyright 2013
Vertex Standard LMR, Inc.
All rights reserved.
No portion of this manual
may be reproduced
without the permission of
Vertex Standard LMR, Inc.
Printed in China
Declaration of Conformity
We, YAESU UK Ltd. declare under our sole responsibility that the
following equipment complies with the essential requirements of the
Directive 1999/5/EC.
Type of Equipment: FM Transceiver
Brand Name: VERTEX STANDARD
Model Number: VX-351-D0-5, VX-354-D0-5,
VX-351-G6-5, VX-354-G6-5
Manufacturer: Vertex Standard Co., Ltd.
Address of Manufacturer: 4-8-8 Nakameguro Meguro-Ku, Tokyo
153-8644, Japan
Applicable Standards:
This equipment is tested and conforms to the essential requirements
of directive, as included in following standards.
EN 300 086-2 V1.3.1
Radio Standard: EN 300 113-2 V1.4.2
EN 301 489-01 V1.8.1
EMC Standard: EN 301 489-05 V1.3.1
EN 60065: 2002 +A1: 2006 +A11: 2008
Safety Standard:
The technical documentation as required by the Conformity Assess-
ment procedures is kept at the following address:
Company: YAESU UK Ltd.
Address: Unit 12, Sun Valley Business Park, Winnall Close
Winchester, Hampshire, SO23 0LB, U.K.
MODEL
VX-351-D0-5
VX-354-D0-5
VX-351-G6-5
VX-354-G6-5
VX-351-G7-5
VX-354-G7-5
FREQUENCY
134-174 MHz
134-174 MHz
400-470 MHz
400-470 MHz
450-512(520) MHz
450-512(520) MHz
TX POWER
5 W
5 W
5 W
5 W
5 W
5 W
DISPLAY/KEYPAD
Non
LCD/4 Key
Non
LCD/4 Key
Non
LCD/4 Key
MODEL REFERENCE
WARRANTY POLICY
Vertex Standard warrants, to the original purchaser only, its Vertex Standard
manufactured communications products against defects in materials and
workmanship under normal use and service for a given period of time from
the date of purchase.
Limited Warranty Details:
North America customers (USA and Canada):
http://www.vertexstandard.com/lmr/warranty-terms.aspx
Customers outside of North America:
Contact the authorized dealer in your country.
Product specificaties
Merk: | Vertex Standard |
Categorie: | Radio communicatie |
Model: | VX-350 Series |
Heb je hulp nodig?
Als je hulp nodig hebt met Vertex Standard VX-350 Series stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Radio communicatie Vertex Standard
21 September 2022
21 September 2022
21 September 2022
21 September 2022
21 September 2022
21 September 2022
21 September 2022
21 September 2022
21 September 2022
21 September 2022
Handleiding Radio communicatie
- Radio communicatie Kenwood
- Radio communicatie Motorola
- Radio communicatie Albrecht
- Radio communicatie Baofeng
- Radio communicatie Furuno
- Radio communicatie GTV
- Radio communicatie Icom
- Radio communicatie Intek
- Radio communicatie Multi Care Systems
- Radio communicatie President
- Radio communicatie Rexon
- Radio communicatie Simrad
- Radio communicatie Spektrum
- Radio communicatie Stabo
- Radio communicatie Swissphone
- Radio communicatie Team
- Radio communicatie Wintec
- Radio communicatie Wouxun
Nieuwste handleidingen voor Radio communicatie
3 September 2023
3 September 2023
2 September 2023
26 Augustus 2023
26 Augustus 2023
31 Januari 2023
31 Januari 2023
14 Juli 2023
31 Januari 2023
13 Mei 2023