Vemer PR-2P3D Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Vemer PR-2P3D (26 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 26 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/26
- 27 -
User Manual Regulators
English
Contents
â– Safety warnings Page 28
â– Technical specifications Page 28
â– Description of instrument Page 31
â– Electrical connections Page 31
â– Glossary Page 32
â– Operation Page 37
â– Setting the regulation parameters Page 37
â– Parameter menu Page 39
â– Error messages Page 46
â– Reference standards Page 47
â– Dimensions and connection diagrams, 33x75 mm Page 48-49
â– Dimensions and connection diagrams, 72x72 mm Page 50
â– Dimensions and connection diagrams, 4-DIN Page 51
- 28 -
User Manual Regulators
English
â–  During the installation and operation of the instrument, follow the
instructions set out below:
1) The instrument should be installed by a skilled operator.
2) Strictly follow the connection diagrams when installing the instrument.
3) Do not power or connect the instrument if any part of it is damaged.
4) Before touching the terminals, make sure the wires to be connected to
the instrument are not live.
5) The connection cables should be able to resist the maximum operating
temperature (Tmax), obtained from the sum of the maximum ambient
temperature (Ta) + a temperature of 20 °C (Tmax= Ta + 20 °C).
6) The instruments guarantee a main insulation between the low voltage
(250 V) and very low voltage parts.
7) Any outside switches connected to the controls should guarantee a
minimum insulation at operating temperature of 250 V AC, or should be
protected by equivalent insulation.
8) Contacts: all type 1C (CEI 107-70 and variants).
9) The instruments require no maintenance.
â– Series of digital regulators used for the most simple requirements in the control
and regulation of humidity and pressure levels in air conditioning, heating
and refrigeration systems
â– Two dedicated base models for pressure and humidity control:
- DIGITAL HUMIDITY REGULATORS HR
- DIGITAL PRESSURE REGULATORS PR
â– Each single model has 1 probe input for the connection of active sensors
with standardised 0÷20 mA, 4÷20 mA and 0÷1 V outputs
â– The power supply to the active probe (linear sensor) comes directly from
the instrument: 9 V DC available
• For each single model, the probe input can be configured from the keyboard
• Available in versions with 1 or 2 relay outputs with contact in exchange
• Regulators with 3 digit, seven segment and decimal point display
• Relay intervention warning lamp
• Display range: -99 ÷ +999
• Display resolution: 0.1 RH or bar (-9.9 ÷ +99.9 RH or bar)
and 1 RH or bar (< -9.9 °C and > +99.9 RH or bar)
• Precision: ±0.5 % of the end of scale value ±1 digit
(at an ambient temperature of 23 °C)
• Sampling time: 0.5s
TECHNICAL SPECIFICATIONS
SAFETY WARNINGS
- 29 -
User Manual Regulators
English
• Parameter setting in digital mode:
- Set point
- Differential
- Neutral zone
- Output drive timing
- Digital input delay function and time
- Alarm delay / buzzer enable time
- Probe calibration offset
- Resolution displayed
- Measurement display filter (update speed)
- Type of probe input
- Password
- Operating modes (regulation):
— ON/OFF Direct and/or Reverse action with or without neutral zone
— PWM Direct and Reverse action with or without neutral zone
— ALARM
— Special mode
• 2 independent set points
• Digital input: 1 (not versions HR-..P7A, PR-..P7A) for outside consensus
for configurable function: outside alarm, regulator ON/OFF, set-point switching,
Direct/Reverce switching, etc.
Acoustic and visual alarm signalling for: outside alarm (from digital input),
probe alarm (malfunction), minimum or maximum alarm
• Infrared receiver with RC-5 protocol for remote control (accessory available
separately for remote programming)
• Available in the following fixing versions: 33x75 mm rear panel, 72x72 mm
rear panel and modular 4 DIN
• Power supply: see table on the following page
• Rated power: 3 VA for models with 33x75 mm rear panel fixing
4.5 VA for models with 72x72 mm and modular 4 DIN fixing
• Max absorption: 100 mA at 12 V - 50 mA at 24 V (1 channel)
• Operating temperature: 0 ÷ +50 °C
• Operating humidity: <80%
• Storage temperature: -10 ÷ +70 °C (<80% RH)
• Protection level: front panel IP54 (IP40 for the 4 DIN module version)
terminals IP20


Product specificaties

Merk: Vemer
Categorie: Niet gecategoriseerd
Model: PR-2P3D

Heb je hulp nodig?

Als je hulp nodig hebt met Vemer PR-2P3D stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Vemer

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd