Vemer EVA-2DIN Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Vemer EVA-2DIN (1 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 36 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
3CONNECTION DIAGRAMS
2
V3IS00261–100
DIMENSIONS
1User Manual
TRMS DIGITAL AMMETER
 Read all the instructions carefully
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
Tel +39 0439 80638 • Fax +39 0439 80619
e-mail: info@vemer.it - web site: www.vemer.it
Mod. EVA-2DIN
EVA-R
EVA-2DIN
EVA-R
36 60
45
65
88
5
72 75
72
66
EVA-2DIN
EVA-R
EVM is an electronic device to measure true effective value (TRMS) of
alternate currents in single-phase systems.
Code Model Description
VM257300 EVA-2DIN Ammeter AC 2DIN
VM324100 EVA-R VAmmeter AC 72x72mm
SAFETY WARNINGS
During the installation and operation of the device, proceed in accordance
with the instructions below:
1) The device should be installed by a competent operator following the
connection diagrams carefully
2) Do not power or connect the device if any part of it is damaged
3) The device should be installed in a panel from which no access can be
gained to the terminals after installation
4) The electrical system of the building in which the instrument is to be
installed should have a switch and a protective device against over-currents
5) The device is designed for installations with over-voltage category III and
pollution level 2, in accordance with the EN 61010-1 standard.
6) The device must be installed and put into operation in accordance with the
current regulations regarding electrical systems.
TECHNICAL SPECIFICATIONS
• Power supply
- 230 V AC (-15% ÷ +10%) 50/60Hz
- Maximum consumption: 2 VA
• Current measurements:
- direct connection up to 10A
- resolution: 10mA
- minimum measurable signal: 300 mA
- accuracy: ± 0.5% of full scale ± 1 digit (from 3% to 100% of F.S.)
- maximum power consumption: 1.5 VA
• Terminals for links:
- connection blocks for cables with 6 mm² maximum cables section for EVA-
2DIN
- plug-in terminal block for cables with 2.5 mm² maximum cables section up
for EVA-R
• 3-digits 7-segments LED display for viewing the measured quantity
• Operating temperature: -10°C to + 45°C
• Storage temperature: -20°C to + 70°C
• Relative humidity: 10% to 90% non-condensing
• Insulation: power supply circuits and electrically insulated measurement at
the level of main insulation (EN 61010-1). Accessible parts and other insulated
terminals at reinforced insulation level
• Protection degree: IP20 / IP51 on the front
4OPERATION
During normal operation, the device displays the
measured value of the current.
Error messages
• Memory error: EEE
Indicates a damage of the device that affect the
operation
• Overload Error: KKK
Indicates that the current is higher than the maximum
allowed value: I > 9.99A
Reset is automatic
• Error: 000
Indicates that the measured curent is lower than
300 mA
REFERENCE STANDARS
Conformity to the EU directives:
2014/35/UE (LDV), 2014/30/UE (EMCD)
is declared with reference to the following harmonised standards:
• EN 61010-1, EN 61000-6-2 and EN 61000-6-4
03-2018
5 4 3 12
2
3
0
V
~
5
0
-
6
0
H
z
~
A
+
2
3
0
V
~
5
0
-
6
0
H
z
~
+
A
2
3 4
1
6
7 8
5


Product specificaties

Merk: Vemer
Categorie: Niet gecategoriseerd
Model: EVA-2DIN

Heb je hulp nodig?

Als je hulp nodig hebt met Vemer EVA-2DIN stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Vemer

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Electrolux

Electrolux STA9 Handleiding

23 November 2024
Electrolux

Electrolux UMP3 Handleiding

23 November 2024
Bosch

Bosch HEZ8TK36UC Handleiding

23 November 2024
Bosch

Bosch HEZ8ZZ36UC Handleiding

23 November 2024
Bosch

Bosch HDZIT301 Handleiding

23 November 2024
Bosch

Bosch HEZBS301 Handleiding

23 November 2024
LG

LG LX-330 Handleiding

23 November 2024
Bosch

Bosch KSZ2AVU00 Handleiding

22 November 2024