Velleman DCM330 Handleiding
Velleman
Multimeter
DCM330
Lees hieronder de 📖 handleiding in het Nederlandse voor Velleman DCM330 (29 pagina's) in de categorie Multimeter. Deze handleiding was nuttig voor 83 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/29
DCM330
DIGITAL CLAMP MULTIMETER
DIGITALE STROOMTANG
PINCE AMPÈREMÉTRIQUE NUMÉRIQUE
PINZA AMPERIMÉTRICA DIGITAL
DIGITALE STROMZANGE
MULTIMETRO DIGITALE CON PINZA AMPEROMETRICA
USER MANUAL
GEBRUIKERSHANDLEIDING
NOTICE D’EMPLOI
MANUAL DEL USUARIO
BEDIENUNGSANLEITUNG
MANUALE UTENTE
DCM330_v2 VELLEMAN
2
DCM330 – DIGITAL CLAMP MULTIMETER
1. Introduction
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that disposal of the
device after its lifecycle could harm the environment. Do not dispose of the
unit (or batteries) as unsorted municipal waste; it should be taken to a
specialized company for recycling. This device should be returned to your
distributor or to a local recycling service. Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Velleman! Please read the manual thoroughly before bringing this
device into service. If the device was damaged in transit, do not install or use it and contact
your dealer.
2. Safety Instructions
• Damage caused by disregard of certain guidelines in this manual is not covered by
the warranty and the dealer will not accept responsibility for any ensuing defects or
problems.
• Switch off the meter when not in use.
• Do not exceed the maximum allowable input range of any function.
• Do not apply voltage to the meter when the resistance function is enabled.
• Set the function switch to the appropriate position before measuring.
• Do not switch to current/resistance modes when measuring a voltage.
• Do not measure current on a circuit whose voltage exceeds 240V.
• Always disconnect the test leads from the circuit under test when changing ranges
with the selector switch.
• Note that damage caused by user modifications to the device is not covered by the
warranty.
• Keep the device away from children and unauthorised users.
3. General Guidelines
• Improper use of this meter can cause damage, shock or injury. Read and understand
this manual before operating this meter.
• Always remove the test leads before replacing the battery.
• Inspect the condition of the test leads and the meter for any damage before operating.
Repair any damage or replace before use.
• Use great care when making measurements of voltages higher than 25VAC RMS or
35VDC. These voltages are considered hazardous.
• Remove the battery if the meter is to be stored for long periods.
• Always discharge capacitors and remove power from the device under test before
performing diode, resistance or continuity tests.
• Voltage checks on electrical outlets can be difficult and misleading because of the
uncertainty of connection to the recessed electrical outlets. Other means should be
used to ensure that the terminals are not live.
Refer to the manual for further information.
Double insulation.
Hazardous voltages may be present under normal use.
DCM330_v2 VELLEMAN
3
• If the equipment is used in a manner not specified in this manual, the protection
provided by the equipment may be impaired.
Input Limits
Function Maximum Input
A
AC 400
A
VDC, VAC 600V DC/AC
Resistance, diode, continuity 250V DC/AC
4. Description
1. clamp meter
2. clamp opening lever
3. rotary selector switch
4. LCD
5. MAX button
6. data hold button
7. mode selection button
8. range selection button
9. backlight button
10. COM input jack
11. V/Ω jack
12. battery cover
AC DC
A
C/DC current measurement
minus sign
1.8.8.8 measurement reading
AUTO auto range mode (except for A ranges)
MAX MAX hold mode
diode test
audible continuity
HOLD data hold mode
BAT low battery icon
°C °F m
V A K M
Ω
measurement units
5. Technical Specifications
Clamp Size opening 23mm (14/16”)
Diode Test Current 0.3mA typical; open circuit voltage 1.5VDC
Continuity Check threshold < 120Ω; test current < 1mA
Low Battery Indication “ ” is displayed
Overrange Indication “ ” is displayed
Measurement Rate 2 per second, nominal
Input Impedance 7.8M Ω (V DC and AC)
Product specificaties
Merk: | Velleman |
Categorie: | Multimeter |
Model: | DCM330 |
Gewicht: | 210 g |
Backlight: | Ja |
DC voltage bereik: | 0.2 - 600 V |
Afmetingen (B x D x H): | 205 x 70 x 37 mm |
Data hold: | Ja |
AC voltage bereik: | 0.2 - 600 V |
AC stroom bereik: | 0.001 - 400 A |
Weerstand bereik: | 200 - 20000000 Ohm |
Continuiteit check: | Ja |
Basische nauwkeurigheid (AC stroom): | ±(2.5%+6d), ±(2.5%+4d), ±(3.0%+4d) |
Basische nauwkeurigheid (AC voltage): | ±(1.5%+3), ±(1.5%+30d) |
Basische nauwkeurigheid (resistantie): | ±(2.0%+4d), ±(1.5%+2d), ±(2.0%+3d), ±(3.0%+5d) |
Basische nauwkeurigheid (DC voltage): | ±(1.2%+3d), ±(0.5%+5d) |
Heb je hulp nodig?
Als je hulp nodig hebt met Velleman DCM330 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Multimeter Velleman
3 December 2024
23 November 2023
26 Juli 2023
16 Juni 2023
22 Mei 2023
27 November 2022
27 November 2022
30 April 2023
24 April 2023
24 April 2023
Handleiding Multimeter
- Multimeter Abus
- Multimeter Aldi
- Multimeter Alecto
- Multimeter Altai
- Multimeter Amiko
- Multimeter Amprobe
- Multimeter Appa
- Multimeter Basetech
- Multimeter Beha-Amprobe
- Multimeter Benning
- Multimeter Brandson
- Multimeter Brennenstuhl
- Multimeter Bruder Mannesmann
- Multimeter Digitus
- Multimeter Elma
- Multimeter Elro
- Multimeter Extech
- Multimeter Ferm
- Multimeter Flir
- Multimeter Fluke
- Multimeter Gembird
- Multimeter Gossen Metrawatt
- Multimeter Greenlee
- Multimeter Hager
- Multimeter Hubinont
- Multimeter Ideal
- Multimeter Keithley
- Multimeter Kingcraft
- Multimeter Laserliner
- Multimeter Mastech
- Multimeter Maxwell
- Multimeter Megger
- Multimeter Metrel
- Multimeter Metrix
- Multimeter Micronta
- Multimeter Milwaukee
- Multimeter Monacor
- Multimeter Parkside
- Multimeter PCE Instruments
- Multimeter Perel
- Multimeter Plieger
- Multimeter Powerfix
- Multimeter Profile
- Multimeter Sanwa
- Multimeter Schneider
- Multimeter Silverline
- Multimeter Skandia
- Multimeter Stanley
- Multimeter TFA
- Multimeter Topcraft
- Multimeter Uni-T
- Multimeter Voltcraft
- Multimeter Wiha
- Multimeter Workzone
- Multimeter Joy-it
- Multimeter Jung
- Multimeter Clas Ohlson
- Multimeter Steren
- Multimeter Klein Tools
- Multimeter EMOS
- Multimeter Tacklife
- Multimeter Biltema
- Multimeter REV
- Multimeter Etekcity
- Multimeter Testo
- Multimeter Somogyi
- Multimeter Testboy
- Multimeter Yato
- Multimeter Wago
- Multimeter GW Instek
- Multimeter Kyoritsu
- Multimeter Owon
- Multimeter Projecta
- Multimeter Cablexpert
- Multimeter Högert
- Multimeter Multimetrix
- Multimeter Digi-tool
- Multimeter Kewtech
- Multimeter Sonel
- Multimeter Testec
- Multimeter Vimar
- Multimeter Strex
- Multimeter PeakTech
- Multimeter MBS
- Multimeter MGL Avionics
- Multimeter Rigol
- Multimeter Chauvin Arnoux
- Multimeter Aim TTi
- Multimeter CEM
- Multimeter Horex
- Multimeter Cosinus
- Multimeter Kurth Electronic
- Multimeter IWH
- Multimeter Weltron
- Multimeter Rohde & Schwarz
- Multimeter EEVBlog
- Multimeter Weidmüller
- Multimeter HT Instruments
- Multimeter Caltek
- Multimeter Elworks
- Multimeter Qian
- Multimeter Bearware
- Multimeter Noyafa
Nieuwste handleidingen voor Multimeter
16 December 2024
7 December 2024
7 December 2024
5 December 2024
5 December 2024
2 December 2024
1 December 2024
1 December 2024
1 December 2024
1 December 2024