VänEE 44252 Handleiding

VänEE Airco 44252

Lees hieronder de 📖 handleiding in het Nederlandse voor VänEE 44252 (9 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 4 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/9
21777J
USER AND INSTALLER MANUAL
INSTALLER: READ THESE INSTRUCTIONS
SAVE THEM FOR USER
RESIDENTIAL USE ONLY
VB0200
VB0201
SIDE PORTS TOP PORTS
K7 ERV (44162)
K8 HRV (44152)
K10 HRV K10 HRV (44502) (44500)
40E (44262)
40H+ (44252)
50H 50H (44602) (44600)
Venmar Ventilation ULC, 550 Lemire Blvd., Drummondville, Québec, Canada J2C 7W9 venmar.ca 800-567-3855
2
Please take note that this manual uses the following symbols to emphasize particular information:
Identifies an instruction which, if not followed, might cause serious personal injuries including possibility of death.
CAUTION
Denotes an instruction which, if not followed, may severely damage the unit and/or its components.
NOTE: Indicates supplementary information needed to fully complete an instruction.
LIMITATION
For residential (domestic) installation only. Installation work and electrical wiring must be done by a qualified person in accordance with all
applicable codes and standards, including fire-rated construction codes and standards.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
2. Before servicing or cleaning this unit, disconnect power cord from electrical outlet.
3. This unit is not designed to provide combustion and/or dilution air for fuel-burning appliances.
4. When cutting or drilling into a wall or ceiling, do not damage electrical wiring and other hidden utilities.
5. Do not use this unit with any solid-state speed control device other than those specified in section 7.1.
6. This unit must be grounded. The power supply cord has a 3-prong grounding plug for your personal safety. It must be plugged into a
mating 3-prong grounding receptacle, grounded in accordance with the national electrical code and local codes and ordinances. Do
not remove the ground prong. Do not use an extension cord.
7. Do not install in a cooking area or connect directly to any appliances.
8. Do not use to exhaust hazardous or explosive materials and vapors.
9. When performing installation, servicing or cleaning this unit, it is recommended to wear safety glasses and gloves.
10. When applicable local regulation comprises more restrictive installation and/or certification requirements, the aforementioned
requirements prevail on those of this document and the installer agrees to conform to these at his own expense.
11. Due to the weight of the unit, two installers are recommended to perform installation.
CAUTION
1. To avoid prematurely clogged filters, turn the unit OFF during construction or renovation.
2. Please read specification label on product for further information and requirements.
3. Be sure to duct air outside – Do not intake/exhaust air into spaces within walls or ceiling or into attics, crawl spaces, or garage.
Do not attempt to recover the exhaust air from a dryer or a range hood.
4. Intended for residential installation only in accordance with the requirements of NFPA 90B (for a unit installed in U.S.A.) or Part 9 of
the National Building Code of Canada (for a unit installed in Canada).
5. Do not run any air ducts directly above or within 2 ft (0.61 m) of a furnace or its supply plenum, boiler, or other heat producing
appliance. If a duct has to be connected to the furnace return plenum, it must be connected 10’ (3.1 m) away from plenum’s
connection to the furnace.
6. The ductwork is intended to be installed in compliance with all applicable local and national codes.
7. When leaving the house for a long period of time (more than two weeks), a responsible person should regularly check if the unit
operates adequately.
8. If the ductwork passes through an unconditioned space (e.g.: attic), the unit must operate continuously except when performing
maintenance and/or repair. Also, the ambient temperature of the house should never drop below 18°C (65°F).
9. At least once a year, the unit mechanical and electronic parts should be inspected by qualified service personnel.
10. Do not use your unit during construction or renovation of your house or when sanding drywall. Certain types of dust and vapors may
damage your system.
11. During the winter season, make sure that the outside intake and exhaust hoods are free from any snow. It is important to check your
unit during a big snow storm, so it doesn’t draw in any snow. If this is the case, please turn the unit OFF for a few hours.
12. Since the electronic control system of the unit uses a microprocessor, it may not operate correctly because of external noise or very
short power failure. If this happens, unplug the unit and wait approximately 10 seconds. Then, plug the unit in again.
13. Do not make excessive use of fragrance appliances or chemicals since some may damage the unit components material.
WARNING
3
PRODUCT REGISTRATION CARD - FICHE D’ENREGISTREMENT DU PRODUIT
Country Pays E-mail address Courriel Language preferred Langue de correspondance
Address Adresse Postal code Code postalApt. no. App. City Ville Province
First name - Pnom Last name Nom de famille
Model no. N
o
de modèle Serial N
o
de série
BACK / VERSO
Centre d’enregistrement de produit - Product registration center, 550 boulevard Lemire, Drummondville, Qbec Canada J2C 7W9
IMPORTANT: Please complete and return this questionnaire within 10 days of your purchase to the address below. Note that only the questions on this side of the page are
mandatory. Your answers will be used for market research studies and reports, and will help us to better serve you in the future. IMPORTANT:
Veuillez remplir ce questionnaire
et nous le retourner dans les 10 jours suivant votre achat à ladresse inscrite en bas de la page. Veuillez noter que seules les questions de ce-ci de la page sont obligatoires.
Vos réponses serviront à des études de marché et nous aideront à mieux vous servir dans l’avenir.
Date of purchase Date d’achat
/ /
Telephone (day) N
o
de téléphone (jour)
- -
Telephone (evening) N
o
de téléphone (soir)
- -
no.
no.
no.
FOR THE USER ...................................... 4
1. USING THIS UNIT ..................................... 4
1.1 Your ventilation system .......................................... 4
1.2 Integrated Control.................................................. 4
2. MAINTENANCE ......................................... 5
2.1 Quarterly Maintenance .........................................5
2.2 Annual Maintenance ............................................. 5
3. USER’S TROUBLESHOOTING ................. 5
4. WARRANTY ............................................... 6
FOR THE INSTALLER ............................. 7
5. AIR DISTRIBUTION ................................... 7
6. INSTALLATION .......................................... 7
6.1 Locating the Unit .................................................. 7
6.2 Installing the ductwork and registers .................... 8
6.2.1 Fully ducted system ................................................. 8
6.2.2 Central draw point system - Supply Side ................. 8
6.2.3 Central draw point system - Return Side ................. 9
6.2.4 Simplified Installation - Supply/Return .................... 9
6.2.5 Simplified Installation - Return/Return..................... 9
6.3 Installing the Exterior Hoods .............................. 10
6.4 Installing Dual Exterior Hood Using Tandem®*
Transition Kit (optional) ............................................. 10
6.5 Connecting the Ducts to the Unit ........................ 11
6.6 Connecting the Drain .......................................... 11
7. CONTROLS ...............................................12
7.1 Electrical connection to optional controls ............ 12
7.1.1 Altitude or Platinum .................................................12
7.1.2 Deco-Touch .............................................................12
7.1.3 Lite-Touch Constructo, Simple-Touch Constructo,
Lite-Touch Bronze or Simple-Touch Bronze ............13
7.1.4 Constructo or Bronze ..............................................13
7.1.5 Optional Auxiliary Controls ......................................13
7.2 Setting Extended Defrost .................................... 13
7.3 Electrical Connection to the Furnace .................. 14
8. BALANCING THE UNIT ............................14
9. WIRING DIAGRAMS .................................15
9.1 K7 ERV and 40E Units ....................................... 15
9.2 K8 HRV and 40H+ Units ..................................... 16
9.3 K10 HRV and 50H Units ..................................... 17
10. SERVICE PARTS ....................................18
11. TROUBLESHOOTING .............................19
TABLE OF CONTENTS


Product specificaties

Merk: VänEE
Categorie: Airco
Model: 44252

Heb je hulp nodig?

Als je hulp nodig hebt met VänEE 44252 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco VänEE

Handleiding Airco

Nieuwste handleidingen voor Airco