Tripp Lite SRXCOOL12KEUB Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Tripp Lite SRXCOOL12KEUB (64 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 12 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/64
Portable Air Conditioning Unit
SRXCOOL12KEU – Series Number: AG-0677 (230V, 50 Hz)
SRXCOOL12KEUB – Series Number: AG-0677 (230V, 50 Hz)
Owner’s Manual
Introduction 2
Important Safety Instructions 2
Features 4
Installation 5
Operation 9
Cleaning and Maintenance 10
Troubleshooting 11
Optional Accessories 11
Storage and Transportation 12
Service and Service Precautions 12
Circuit Diagrams 15
Warranty and Product Registration 15
Regulatory Compliance 16
Español 17
Français 33
Русский 49
1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/support
Copyright © 2021 Tripp Lite. All rights reserved.
2
Introduction
The self-contained Portable Air Conditioning Unit provides 12,000 BTU (up to 3.4 kW) of supplemental cooling capacity. Designed for IT
environments, it’s ideal for cooling overheated rack enclosures, IT equipment hot spots and network closets without access to facility air
conditioning. The Portable Air Conditioning Unit can focus cool air through its flexible cooling duct or cool a small room through its louvered vent.
It also filters and dehumidifies air to improve operating conditions and equipment reliability. Condensate is re-evaporated for drip-free operation,
so you won’t waste time emptying water collection tanks. The self-contained design does not require any plumbing or special circuits, so setup is
quick and easy. Eco-friendly R290 refrigerant meets environmental standards.
Recommended Applications:
Important Safety Instructions
VERY IMPORTANT - SAVE THESE INSTRUCTIONS
Do not install and use your portable air conditioner unit before carefully reading this instruction guide.
Please retain this manual brochure for product warranty and future reference.
This manual contains instructions and warnings that should be followed during the installation, operation
and storage of this product. Failure to heed these warnings may affect your warranty.
Warnings
The individual user should determine prior to use whether this device is suitable, adequate or safe for the use intended. Since individual
applications are subject to great variation, the manufacturer makes no representation or warranty as to the suitability or fitness of this device
for any specific application.
Install the unit indoors, away from extreme temperatures or humidity, direct sunlight, dust and conductive contaminants.
Leave adequate space around the unit for ventilation, with rear and vented sides not less than 20 inches (51 cm) from walls or other obstacles.
Install the unit on a flat surface with a gradient no more than 10°.
Connect the unit directly to a grounded AC power outlet. Failure to do so may cause an electric shock or fire.
This unit is designed to supply supplemental cooling for localized hot spots.
The power supply for the unit must be rated in accordance with the unit’s nameplate.
Do not modify the plug nor use an adapter that would eliminate the ground connection.
Do not use an extension cord to connect the unit to an AC outlet. Use only the power cord that came with the unit.
This appliance shall be installed in accordance with national wiring regulations.
Do not plug additional equipment into the outlet where the unit is plugged in. Overloading the outlet may cause an electric shock or fire.
Do not attempt to turn the unit on or off by connecting or disconnecting the AC plug. A serious electric shock may occur. Use the ON/OFF
button to turn the unit on or off.
Turn the unit off and unplug it from the AC outlet before performing maintenance.
Before connecting the unit to a dedicated drainage system, turn it off and unplug it. There is a risk of electric shock while the unit is plugged in.
Do not use thinners, alcohol, detergents or abrasive brushes to clean the unit’s cabinet. These items may damage the cabinet.
Do not pour water over the unit. This may cause an electric shock and damage the unit.
Do not operate the unit without the air filter. This may cause dust accumulation that may damage the unit.
Do not attempt to operate the unit in a room with inadequate air circulation. Provide makeup air in accordance with applicable building codes.
Do not place objects on top of the unit.
Do not operate your air conditioner in a wet room, such as a bathroom or laundry room. Do not attempt to install this appliance as a window
air conditioner.
Do not exceed operating temperature range for this unit is 17°C - 35°C.
• Do not use any means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
Cooling an overheated rack enclosure.
Cooling an equipment hot spot inside or outside a rack enclosure.
Cooling a small room.
3
Important Safety Instructions
• The appliance must be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance
or an operating electric heater.)
• Do not dispose of any part of this unit in a fire.
• Be aware that refrigerants used may not contain an odor.
• Appliance should be installed, operated and stored in a room with a floor area larger than 13 m
2.
• Servicing should be performed only as recommended by the manufacturer.
• The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
• All working procedure that affects safety means should only be carried by competent persons.
• Please make sure the inlet and outlet ventilation are not blocked at all times.
• Do not operate this unit in an explosive or corrosive atmosphere.
• Clean air filter periodically for the most efficient cooling.
• When the unit is shut off, please wait at least 3.5 minutes before restarting this is to prevent the compressor from being damaged.
• This unit needs at least 7 Amps of electricity to have its compressor operational. Do not use any extension cord with this unit.
• When the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid
hazard.
• This appliance is suitable for use in locations where children are likely to be present.
• This appliance can be used by children aged from 8 years and above and persons with lack of experience and knowledge if they have been
given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
• Children must be supervised to ensure that they do not use the device as a toy.
• Cleaning and user maintenance should not be made by children without supervision.
Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life
support equipment or to significantly affect its safety or effectiveness is not recommended.
Impedance Declaration
We declare these models be connected only to a supply with the relevant system impedance no more than 0.219 ohm. Restrictions to
connection may be imposed by the supply authority on the use of equipment if the actual relevant system impedance at the interface point on
the user’s premise exceeds 0.219 ohm. If necessary, consult your supply authority for system impedance information.


Product specificaties

Merk: Tripp Lite
Categorie: Niet gecategoriseerd
Model: SRXCOOL12KEUB
Soort bediening: Touch
Kleur van het product: Zwart
Gewicht: 33570 g
Breedte: 300 mm
Diepte: 505 mm
Hoogte: 778 mm
Type stekker: Type G
Snoerlengte: 1.83 m
Geluidsniveau: 65 dB
Gewicht verpakking: 38100 g
Breedte verpakking: 381 mm
Diepte verpakking: 853.4 mm
Hoogte verpakking: 863.6 mm
Soort: Mobiele airconditioner uit één stuk
Gebruikershandleiding: Ja
Materiaal behuizing: Acrylonitrielbutadieenstyreen (ABS)
LED-indicatoren: Ja
Geschikt voor ruimtes tot: 33 m²
Koelend medium: R290
Land van herkomst: China
Kleur behuizing: Zwart
Duurzaamheidscertificaten: CE, RoHS, UKCA
Air conditioner functies: Cooling, Dehumidifying
Jaarlijks energieverbruik (koelen): - kWu
Naleving van duurzaamheid: Ja
Koelcapaciteit in watt (opgegeven): 3500 W
Energieverbruik per uur (koeling): - kWu
Energieverbruik per uur (verwarming): - kWu
Ontvochtiging capaciteit: 2.5 L/u
Koelcapaciteit (max): 12000 BTU/h
Koel capaciteit in watt (max): - W
Verwarmingscapaciteit in watt (max): - W
Verwarmingscapaciteit in watt (opgegeven): - W
Compressor type: Draaiknop
Hoeveelheid per (buitenste) hoofdverpakking: 1 stuk(s)
AC-ingangsspanning: 208 - 240 V
AC-ingangsfrequentie: 50 Hz

Heb je hulp nodig?