Tripp Lite SMX1000LCD Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Tripp Lite SMX1000LCD (32 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 57 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/32
Owner’s Manual
SMX1000LCD
Digital UPS System
(Series Number: AGOM5506)
Not suitable for mobile applications
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2018 Tripp Lite. All rights reserved.
Important Safety Instructions 2
Quick Installation 3
Basic Operation 4
Storage & Service 6
Regulatory Compliance 6
Español 7
Français 13
Русский 19
Deutsch 25
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation, operation and storage of all
Tripp Lite UPS Systems. Failure to heed these warnings will void your warranty.
UPS Location Warnings
The UPS is designed for indoor use only in a controlled environment, away from excess moisture, heat/cold, conductive contaminants, dust
or direct sunlight.
Leave adequate space around all sides of the UPS for proper ventilation.
Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously inhibit the
unit’s internal cooling, eventually causing product damage not covered under warranty.
UPS Connection Warnings
Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS into itself; this will damage the UPS.
Do not modify the UPS plug, and do not use an adapter that would eliminate the UPS ground connection.
Do not use extension cords to connect the UPS to an AC outlet. Your warranty will be voided if anything other than Tripp Lite surge
suppressors are used to connect your UPS to an outlet.
If the UPS receives power from a motor-powered AC generator, the generator must provide clean, filtered, computer-grade output.
The AC plug serves as disconnect. The electrical outlets supplying power to the equipment should be installed near the equipment and
easily accessible.
Equipment Connection Warnings
Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the
life support equipment or to significantly affect its safety or effectiveness is not recommended.
Do not connect surge protectors or extension cords to the output of your UPS. This might damage the UPS and will void the surge
protectors and UPS warranties.
Battery Warnings
Your UPS does not require routine maintenance. Do not open your UPS for any reason. There are no user-serviceable parts inside.
Batteries can present a risk of electrical shock and burn from high short-circuit current. Observe proper precautions. Do not dispose of the
batteries in a fire. Do not open the UPS or batteries. Do not short or bridge the battery terminals with any object. Unplug and turn off the
UPS before performing battery replacement. Use tools with insulated handles. There are no user-serviceable parts inside the UPS. Battery
replacement should be performed only by authorized service personnel using the same number and type of batteries (Sealed Lead-Acid).
The batteries are recyclable. Refer to your local codes for disposal requirements or visit http://www.tripplite.com/support/recycling-program
for recycling information. Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges (R.B.C.).Visit Tripp Lite on the
Web at http://www.tripplite.com/products/battery-finder/ to locate the specific replacement battery for your UPS.
Do not attempt to add external batteries to the UPS.
3
Quick Installation
STEP 1: Place the UPS in either
a horizontal or vertical (“tower”)
position.
The UPS housing is designed with sides that slope
slightly in order to tilt the LCD Display up for easy
viewing in either position—horizontal or vertical. As
another aid to easy viewing, the LCD Display can be
rotated. To rotate the display: carefully insert a small
tool in the slots on the sides of the display to pop it
out of the UPS housing; rotate the display, and snap it back into the UPS housing.
CAUTION: To safely balance the UPS when it is placed in a vertical (“tower”) position, make sure the LCD Display is located
at the top of the front panel.
STEP 2: Using your computer’s detachable power cord, plug the UPS into a wall outlet.
Remove your computer’s detachable power cord. Insert the female plug of the computer’s cord into your UPS AC input. Insert the male plug
of your computer’s cord into an AC wall outlet that does not share a circuit with a heavy electrical load (such as an air conditioner or
refrigerator).
After plugging the UPS into a wall outlet, push the ON/OFF button for one second to turn the UPS on (see Basic Operation section).
Note: The UPS will not turn on automatically in the presence of live utility power.
STEP 3: Plug your equipment into the UPS.*
Insert the female plug of the detachable power cord that came with your UPS into the computer’s AC
input. Insert the UPS cord’s male plug into any of your UPS female output receptacles. Select outlets
(see diagram) will provide battery backup and surge protection; plug your computer, monitor and
other critical devices here. Select outlets (see diagram) will provide surge protection only; plug your
printer and other non-essential devices here.
* Your UPS is designed to support electronic equipment only. You will overload the UPS if the total VA ratings for
all the equipment you connect to the Battery Backup Protected/Surge Protected outlets exceeds the UPS Output
Capacity. To find your equipment’s VA ratings, look on their nameplates. If the equipment is listed in amps,
multiply the number of amps by 230 to determine VA. (Example: 1 amp × 230 = 230 VA). If you are unsure if
you have overloaded the Battery Backup Protected/Surge Protected outlets, run a self-test (see “MUTE/TEST”
Button description).
CAUTION: The UPS must be plugged into a live AC outlet and turned on for 24 hours after initial installation to fully charge
the UPS internal battery. Your connected equipment will receive utility-supplied AC power (if present) immediately after the
UPS is plugged in and turned on; however, your connected equipment may not receive full battery backup in the event of a
blackout or severe brownout unless the UPS internal battery is fully charged.


Product specificaties

Merk: Tripp Lite
Categorie: Niet gecategoriseerd
Model: SMX1000LCD
Kleur van het product: Zwart
Gewicht: 6620 g
Breedte: 88.9 mm
Diepte: 165.1 mm
Hoogte: 300 mm
Snoerlengte: 1.8 m
Gewicht verpakking: 7300 g
Breedte verpakking: 393.7 mm
Diepte verpakking: 279.4 mm
Hoogte verpakking: 364 mm
Vormfactor: Tower
Land van herkomst: China
Certificering: CE (IEC 62040), GOST, SASO, CE Class B
Geluidsalarm(en): Ja
Duurzaamheidscertificaten: RoHS
Uitgangsvermogen: 500 W
Temperatuur bij opslag: -15 - 50 °C
Frequentie: - Hz
Relatieve luchtvochtigheid bij opslag (geen condensering): 0 - 95 procent
Stekker: C14 stekker
(Buitenste) hoofdverpakking hoogte: 276.1 mm
(Buitenste) hoofdverpakking breedte: 400 mm
(Buitenste) hoofdverpakking brutogewicht: 14610 g
(Buitenste) hoofdverpakking lengte: 279.4 mm
Hoeveelheid per (buitenste) hoofdverpakking: 2 stuk(s)
Bedrijfstemperatuur (T-T): 0 - 40 °C
GTIN (EAN/UPC)-nummer (buitenste) hoofdverpakking: 10037332125924
Surge energy rating: 480 J
Aantal AC uitgangen: 6 AC-uitgang(en)
Stopcontacttypes: C13 stekker
Stroom (max.): 10 A
Output power capacity: 1 kVA
Ingang operation voltage (min): 230 V
Ingang operation voltage (max): 230 V
Uitgang operation voltage (min): 220 V
Uitgang operation voltage (max): 240 V
Typische backup tijd op halve lading: 11 min
Typische backup tijd op volledige lading: 3 min
Spanningsbeveiliging: Ja

Heb je hulp nodig?

Als je hulp nodig hebt met Tripp Lite SMX1000LCD stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Tripp Lite

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd