Tripp Lite PDUMH32HV Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Tripp Lite PDUMH32HV (40 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 20 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/40
Owner’s Manual
Metered Rack PDUs
Low-Voltage Models: PDUMH15, PDUMH15S, PDUMH20
High-Voltage Models: PDUMH20HV, PDUMH30HV, PDUMH32HV
Español 9 Français 17 Русский 25 Deutsch 33
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2019 Tripp Lite. All rights reserved.
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an
ISOBAR6ULTRA surge protector—
a $100 value!
www.tripplite.com/warranty
21-03-396-933059.indb 1
21-03-396-933059.indb 1
21-03-396-933059.indb 1
21-03-396-933059.indb 121-03-396-933059.indb 1 4/1/2021 11:48:35 AM
4/1/2021 11:48:35 AM
4/1/2021 11:48:35 AM
4/1/2021 11:48:35 AM4/1/2021 11:48:35 AM
2
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be
followed during the installation, operation and storage of this product.
Failure to heed these instructions may affect your warranty.
CAUTION Only those who are properly trained or qualified to use this device should
do so. Anyone who is not trained or qualified should not use this device unless it is
under the supervision of someone who is properly trained or qualified to do so.
Children must be supervised to ensure that they do not use the device as a toy.
Never use the device if the cord and plug are damaged; if it is not working properly,
or if it has been dropped or damaged, take it to an authorized service center for
inspection and repair.
If the power cord is damaged, it must be replaced by the manufacturer, its authorized
service agent, or by qualified personnel in order to avoid a danger.
Important Warnings
The PDU provides the convenience of multiple outlets, but DOES NOT provide surge or line
noise protection for connected equipment.
The PDU is designed for indoor use only, in a controlled environment, away from excess
moisture, temperature extremes, conductive contaminants, dust or direct sunlight.
Keep indoor ambient temperature between 32°F and 122°F (0°C and 50°C).
The PDU must be installed by a qualified technician only.
Do not attempt to mount the PDU to an insecure or unstable surface.
Install in accordance with National Electrical Code standards. Be sure to use the proper
overcurrent protection for the installation, in accordance with the plug/equipment rating.
Connect the PDU to an outlet that is in accordance with your local building codes and that is
adequately protected against excess currents, short circuits and earth faults.
The electrical outlets supplying power to the equipment should be installed near the equipment
and easily accessible.
Do not connect the PDU to an ungrounded outlet or to extension cords or adapters that
eliminate the connection to ground.
Be sure to provide a local disconnect device on any models that are permanently installed
without a plug that is easily accessible.
Never attempt to install electrical equipment during a thunderstorm.
Individual equipment connected to the PDU should not draw more current than the individual
PDU’s outlet’s rating.
The total load connected to the PDU must not exceed the maximum load rating for the PDU.
Do not attempt to modify the PDU, input plugs or power cables.
Do not drill into or attempt to open any part of the PDU housing. There are no user-serviceable
parts inside.
Do not attempt to use the PDU if any part of it becomes damaged.
Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to significantly
affect its safety or effectiveness is not recommended.
Important Safety Instructions
21-03-396-933059.indb 2
21-03-396-933059.indb 2
21-03-396-933059.indb 2
21-03-396-933059.indb 221-03-396-933059.indb 2 4/1/2021 11:48:35 AM
4/1/2021 11:48:35 AM
4/1/2021 11:48:35 AM
4/1/2021 11:48:35 AM4/1/2021 11:48:35 AM
3
Installation
A
1-1 B
1-2
1-3
Note: The illustrations may differ somewhat from your PDU model.
1 Determine Installation Configuration. The PDUs covered by this owner’s manual support
these installation configurations: 2U, 1U and 0U rackmount; wall-mount and under-counter.
See below for installation configurations pertaining to your specific model. Choose a
configuration and follow the installation instructions in the appropriate section of Step 1
before proceeding to Step 2.
Note: Regardless of installation configuration, the user must determine the fitness of hardware and
procedures before mounting. The PDU and included hardware are designed for common rack and rack
enclosure types and may not be appropriate for all applications. Exact mounting configurations may vary.
1-1 2U Rack Installation. Attach the
included brackets to the side of the
PDU with the included screws A. After
installing the brackets, position the
PDU in the rack and install four user-
supplied screws through the units
brackets and into the rack rails B.
1-2 1U Rack Installation. Attach the PDU
to the rack by inserting four user-
supplied screws A through the PDU
mounting brackets B and into the
mounting holes of the rack rail as
shown.
1-3 0U Rack Installation. Part 1: Remove
the screws C attaching the mounting
brackets to the PDU, change the
orientation of the brackets as shown
and reattach the brackets. Use only
the screws supplied by the
manufacturer or their exact equivalent
(#6-32, 1/4” flat head). Part 2: Attach
the PDU vertically by inserting two or
more user-supplied screws A through
the PDU mounting brackets B and
into mounting points in the rack or
rack enclosure.
A
A
B
B
C
21-03-396-933059.indb 3
21-03-396-933059.indb 3
21-03-396-933059.indb 3
21-03-396-933059.indb 321-03-396-933059.indb 3 4/1/2021 11:48:36 AM
4/1/2021 11:48:36 AM
4/1/2021 11:48:36 AM
4/1/2021 11:48:36 AM4/1/2021 11:48:36 AM


Product specificaties

Merk: Tripp Lite
Categorie: Niet gecategoriseerd
Model: PDUMH32HV
Kleur van het product: Zwart
Gewicht: 6260 g
Breedte: 444.5 mm
Diepte: 317.5 mm
Hoogte: 88.9 mm
Snoerlengte: 3.65 m
Gewicht verpakking: 6670 g
Breedte verpakking: 426.7 mm
Diepte verpakking: 490.2 mm
Hoogte verpakking: 198.1 mm
Materiaal behuizing: Metaal
Beeldscherm: LCD
Land van herkomst: Taiwan
Certificering: CE (IEC 60950-1), UL, CSA, Class A
Duurzaamheidscertificaten: RoHS
Temperatuur bij opslag: -15 - 50 °C
Hoogte, in bedrijf: 0 - 3000 m
Afmetingen (B x D x H): 445 x 317.5 x 89 mm
Montage: Horizontaal
Stekker: IEC309
(Buitenste) hoofdverpakking hoogte: 198.1 mm
(Buitenste) hoofdverpakking breedte: 426.7 mm
(Buitenste) hoofdverpakking brutogewicht: 6670 g
(Buitenste) hoofdverpakking lengte: 490.2 mm
Hoeveelheid per (buitenste) hoofdverpakking: 1 stuk(s)
Rackcapaciteit: 2U
AC-ingangsfrequentie: 50 - 60 Hz
Aantal AC uitgangen: 18 AC-uitgang(en)
Nominale input voltage: 230 V
Stopcontacttypes: C13 coupler, C19 coupler
Stroom (max.): 32 A
PDU types: Gemeten
Netspanning, in bedrijf: 230 V