Tripp Lite OMNIVSINT800 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Tripp Lite OMNIVSINT800 (32 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 29 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/32
1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/support
Copyright © 2022 Tripp Lite. All rights reserved.
Owner’s Manual
230V Input, Line-Interactive
UPS Systems
(Tower Configuration)
Models: OMNIVSINT1000, OMNIVSINT1500XL
*
* Extended runtime options
Not suitable for mobile applications.
Important Safety Instructions 2
Quick Installation 3
Basic Operation 5
Storage & Service 8
Español 9
Français 17
Русский 25
2
Important Safety Instructions
UPS Location Warnings
Install your UPS indoors, away from excess moisture or heat, dust or direct sunlight.
For best performance, keep the indoor temperature between between 32º F and 104º F
(0º C and 40º C).
Leave adequate space around all sides of the UPS for proper ventilation.
UPS Connection Warnings
Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS into
itself; this will damage the UPS.
Do not modify the UPS plug, and do not use an adapter that would eliminate the UPS ground
connection.
Do not use extension cords to connect the UPS to an AC outlet. Your warranty will be voided
if anything other than Tripp Lite surge protectors are used to connect your UPS to an outlet.
If the UPS receives power from a motor-powered AC generator, the generator must
provide clean, filtered, computer-grade output.
Equipment Connection Warnings
Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to significantly
affect its safety or effectiveness is not recommended.
Do not connect surge protectors or extension cords to the output of your UPS.
Battery Warnings
Batteries can present a risk of electrical shock and burn from high short-circuit current.
Observe proper precautions. Do not dispose of the batteries in a fire. Do not open the UPS or
batteries. Do not short or bridge the battery terminals with any object. Unplug and turn off the
UPS before performing battery replacement. Use tools with insulated handles. There are no
user-serviceable parts inside the UPS. Battery replacement should be performed only by
authorized service personnel using the same number and type of batteries (Sealed Lead-
Acid). The batteries are recyclable. Refer to your local codes for disposal requirements.
Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges (R.B.C.).
Visit Tripp Lite on the Web at tripplite.com/support/battery/index.cfm to locate the specific
replacement battery for your UPS.
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation,
operation and storage of all Tripp Lite UPS Systems. Failure to heed these warnings will void
your warranty.
3
Quick Installation
1 Unplug the computer’s power cord from
both AC outlet and the computer’s AC
input.
2 Insert the female plug of the computer’s
cord into the UPS AC input. A Insert the
male plug of the computer's cord into AC
outlet.
Note: After you plug the UPS into a live AC outlet, the
UPS will turn ON automatically. See ON/OFF” Button
description in the Basic Operation section if you want to
place the UPS in any mode other than ON.
3 Using one of the jumper cords supplied
with the UPS, insert the cord’s female
plug into computer’s AC input B. Insert
the cord’s male plug into any of UPS’s
female output receptacles.
4 Plug additional equipment into the UPS.*
Use one of the additional jumper cords supplied
with the UPS, or order additional jumper cords
from Tripp Lite. Log on to tripplite.com/support;
order part # P004-006.
* Your UPS is designed to support only computer
equipment. You will overload the UPS if the total VA
ratings for all the equipment you connect exceeds the
UPS’s output capacity. To find your equipment's VA ratings,
look on their nameplates. If the equipment is listed in
amps, multiply the number of amps by 230 to determine
VA. (Example: 1 amp × 230 = 230 VA). If you are unsure
if you have overloaded the UPS’s outlets, see “OUTPUT
LOAD LEVELLED description.
1
2
IEC320-C14 plug shown
A
3
4
Shown: OMNIVSINT1000
B
Shown: OMNIVSINT1000
Shown: OMNIVSINT1000


Product specificaties

Merk: Tripp Lite
Categorie: Niet gecategoriseerd
Model: OMNIVSINT800
Kleur van het product: Zwart
Gewicht: 8850 g
Breedte: 133.4 mm
Diepte: 190.5 mm
Hoogte: 273 mm
Snoerlengte: 0.2 m
Gewicht verpakking: 9940 g
Breedte verpakking: 190.5 mm
Diepte verpakking: 348 mm
Hoogte verpakking: 246.4 mm
Materiaal behuizing: Polyvinyl chloride (PVC)
LED-indicatoren: Ja
Vormfactor: Tower
Land van herkomst: China
Aantal USB 2.0-poorten: 1
Certificering: UL1778, CE, GOST, SASO, IRAM
Geluidsalarm(en): Ja
Duurzaamheidscertificaten: RoHS
Uitgangsvermogen: 475 W
Accu/Batterij oplaadtijd: 4.5 uur
Temperatuur bij opslag: -15 - 50 °C
Stroomspanning bescherming: Onder spanning
Frequentie: 50/60 Hz
Stekker: C14 stekker
Efficientie: 97 procent
(Buitenste) hoofdverpakking hoogte: 378.5 mm
(Buitenste) hoofdverpakking breedte: 279.4 mm
(Buitenste) hoofdverpakking brutogewicht: 19870 g
(Buitenste) hoofdverpakking lengte: 421.6 mm
Hoeveelheid per (buitenste) hoofdverpakking: 2 stuk(s)
Rackcapaciteit: 2U
Bedrijfstemperatuur (T-T): 0 - 40 °C
Relatieve vochtigheid in bedrijf (V-V): 0 - 95 procent
Code geharmoniseerd systeem (HS): 85078000
GTIN (EAN/UPC)-nummer (buitenste) hoofdverpakking: 10037332120967
Surge energy rating: 340 J
Aantal AC uitgangen: 4 AC-uitgang(en)
Stopcontacttypes: C13 stekker
Golf protectie functies: Telefoon
Stroom (max.): 2.4 A
Output power capacity: 0.8 kVA
Ingang operation voltage (min): 159 V
Ingang operation voltage (max): 230 V
Uitgang operation voltage (min): 220 V
Uitgang operation voltage (max): 240 V
UPS-topologie: Line-interactive
Aantal input fases: 1
Typische backup tijd op halve lading: 11.5 min
Typische backup tijd op volledige lading: 3.5 min
Hot-swap batterij: Ja
Uitgangsspanningsregeling: 5 procent
EMI/RFI geluidsfiltering: Ja
Spanningsbeveiliging: Ja
Golfvorm: Sinus
Koude start: Ja
Automatic Voltage Regulation (AVR): Ja

Heb je hulp nodig?

Als je hulp nodig hebt met Tripp Lite OMNIVSINT800 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Tripp Lite

Handleiding Niet gecategoriseerd