Tripp Lite NetCommander B070-016-19-IP2 Handleiding

Tripp Lite Niet gecategoriseerd NetCommander B070-016-19-IP2

Lees hieronder de šŸ“– handleiding in het Nederlandse voor Tripp Lite NetCommander B070-016-19-IP2 (57 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 27 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/57
1
Ownerā€™s Manual
NetCommanderĀ® IP
Cat5 KVM Switch
Model: B070-016-19-IP2
(Series Number: AG-00C3)
1111 W. 35th Street, Chicago, IL 60609 USA ā€¢ www.tripplite.com/support
Copyright Ā© 2017 Tripp Lite. All rights reserved. All trademarks are the property of their respective owners.
PROTECT YOUR INVESTMENT!
Register your product for quicker service and ultimate peace of mind.
You could also win an ISOBAR6ULTRA surge protectorā€”a $100 value!
www.tripplite.com/warranty
2
Table of Contents
Legal Notice............................3
1. Product Overview. . . . . . . . . . . . . . . . . . . . . . 3
1.1 Features and Beneļ¬ts . . . . . . . . . . . . . . . . . . . . . . . .3
1.2 Terminology
................................
4
1.3 Target Server Compatibility . . . . . . . . . . . . . . . . . . . .4
1.4 Client Computer Compatibility . . . . . . . . . . . . . . . . . .4
1.5 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.6 System Components . . . . . . . . . . . . . . . . . . . . . . . . .5
1.7 The NetCommander IP Unit . . . . . . . . . . . . . . . . . . . .6
1.8 Rackmounting the NetCommander IP . . . . . . . . . . . .8
1.8.1 Standard Console KVM Switch Instructions 8. . . . . . . . . . .
1.8.2 2-Post Rack Console KVM Switch Instructions 8
. . . . . . . .
1.9 Connecting the System
.......................
8
1.10 Initial Settings (Default IP Address) . . . . . . . . . . . .8
2. Web Conļ¬guration Interface
.............
12
2.1 Logging Into the Web Conļ¬guration Interface. . . . . .12
2.2 Web Conļ¬guration Interface Layout . . . . . . . . . . . . .13
2.3 My Targets Section . . . . . . . . . . . . . . . . . . . . . . . . . .14
2.4 Conļ¬guration Section . . . . . . . . . . . . . . . . . . . . . . . .15
2.4.1 Firmware Upgrade 16
............................
2.4.2 Backup/Restore 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.4.3 SSL Certiļ¬cate 19
..............................
2.4.4 Device 20
....................................
2.4.5 Users 21.....................................
2.4.6 Switch Conļ¬guration 22
..........................
2.4.7 User Targets 24
................................
2.4.8 Power Devices 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.4.9 Power Outlets 26
...............................
2.4.10 Serial Ports 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.4.11 Security 27
..................................
2.4.12 Authentication 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.4.13 Date & Time 33
...............................
2.5 Password Section . . . . . . . . . . . . . . . . . . . . . . . . . . .33
2.6 Events Section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
3. Conducting a Remote Session. . . . . . . . . . . . 35
3.1 Starting a Remote Session . . . . . . . . . . . . . . . . . . . .35
3.2 Remote Session Toolbar . . . . . . . . . . . . . . . . . . . . . .36
3.2.1 Pin Toolbar 36
.................................
3.2.2 Session 36
...................................
3.2.3 Video 38.....................................
3.2.4 Power 39.....................................
3.2.5 Keys 40......................................
3.2.6 Mouse 42
....................................
3.2.7 Server/Serial 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2.8 Full Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
3.2.9 Logout 45
....................................
3.3 Shared Session
.............................
45
3.4 Exclusive Session . . . . . . . . . . . . . . . . . . . . . . . . . . .45
4. Local Console ........................46
4.1 Move Label (F1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
4.2 Tuning (F5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
4.3 Power Management . . . . . . . . . . . . . . . . . . . . . . . . . .47
4.4 (F2) Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
5. Serial Port Pinout . . . . . . . . . . . . . . . . . . . . . 50
6. Security Certiļ¬cate Installation . . . . . . . . . . 50
7. Technical Speciļ¬cations . . . . . . . . . . . . . . . . 56
8. Video Resolution and Refresh Rates . . . . . . . 56
9. Warranty and Product Registration . . . . . . . . 57
3
Legal Notice
This manual and the software described in it are furnished under license, and may be used or copied only in accordance with the terms
of such license. The content of this manual is provided for informational use only, and is subject to change without notice. It should not in
and of itself be construed as a commitment by Tripp Lite, which assumes no responsibility of liability for any errors or inaccuracies that may
appear in this book.
The software that accompanies this manual is licensed for use by the Licensee only, in strict accordance with the software license
agreement, which the Licensee should read carefully before commencing use of the software. Except as permitted by the license, no part
of this publication may be reproduced, stored in retrieval system, or transmitted in any form or by any means, electronic, mechanical,
recording, or otherwise, without the prior written permission of Tripp Lite.
1. Product Overview
1.1 Features and Beneļ¬ts
ā€¢ Directly connect up to 16 computers/servers.
ā€¢ Up to 3 users (1 local, 2 remote) can simultaneously access the KVM.
ā€¢ Up to 5 users can share a single remote session.
ā€¢ Multi-level account access: and account types.Administrator User
ā€¢ Remote authentication support; RADIUS and LDAP/S.
ā€¢ Supports both IPv4 and IPv6.
ā€¢ PDU Control - Add IP PDUs as devices that can be controlled by the KVM. Assign individual ports on the KVM to a PDU port to power cycle
or power off/on the computer/server connected to that port.
ā€¢ BIOS level control to any serverā€™s brand and model, regardless of the server condition and network connectivity. Covers the entire spectrum
of crash scenarios.
ā€¢ Compatible with WindowsĀ® and LinuxĀ® operating systems.
ā€¢ Connect computer/servers up to 100 ft. (30 m) away from the KVM using inexpensive Cat5e/6* cabling and B078-101-USB2,
B078-101-USB-1 and B078-101-PS2 SIUs.
ā€¢ Java-based application allows control of a target server via web browser from any location over a secured IP connection.
ā€¢ Features two 10/100 Mbps LAN ports, so that if one fails, the other takes over.
ā€¢ Supports the highest security standards for encryption (128-bit AES and HTTPS).
ā€¢ Virtual Media allows an .iso ļ¬le located in a Shared folder of a SAMBA or NFS server to be mounted to a Target Server and accessed as if
it were directly stored on it.
ā€¢ Supports Virtual Media data transfer rates up to 12Mbps (B078-101-USB2 required). A B078-101-USB-1 can be used to provide Virtual
Media support, but only at speeds up to 1Mbps.
ā€¢ Event log records events that take place on the installation, such as logins, reboots, network settings changes, etc..
ā€¢ Features two RJ45 serial ports for connecting serial manageable devices, such as PDUs, ļ¬rewalls, and routers.
ā€¢ Allows for system sent messages to SNMP server to notify of LAN failures.
ā€¢ Allows for the installation of a SSL certiļ¬cate to ensure secure transactions between the Web servers and browsers.
ā€¢ Graphical OSD and toolbars provide convenient, user-friendly remote operation.
ā€¢ Text based OSD provides convenient, user-friendly local operation.
ā€¢ Supports video resolutions up to 1920 x 1080 @ 60Hz. (B070-console KVMs are limited to video resolutions up to 1366 x 768 at the
local console.)
ā€¢ Flash upgradeable ļ¬rmware over the network.
* To ensure proper functionality, shielded Cat5e/6 cable must be used with the B078-101-USB2, and is recommended for all other SIUs for best performance.


Product specificaties

Merk: Tripp Lite
Categorie: Niet gecategoriseerd
Model: NetCommander B070-016-19-IP2
Kleur van het product: Zwart
Gewicht: 12910 g
Breedte: 477.3 mm
Diepte: 692.4 mm
Hoogte: 43.4 mm
Gewicht verpakking: 19780 g
Breedte verpakking: 591.8 mm
Diepte verpakking: 891.5 mm
Hoogte verpakking: 149.9 mm
AC-adapterfrequentie: 50/60 Hz
AC-adapter ingangsspanning: 100 - 240 V
Stroom: 1.2/0.7 A
Beeldscherm: LCD
Beeldschermdiagonaal: 19 "
Resolutie: 1280 x 1024 Pixels
Land van herkomst: Taiwan
Certificering: UL 60950-1 (USA), CAN/CSA (Canada), FCC Part 15 Class A, CE, IEC 60950-1
Interface: PS/2; USB; VGA
Duurzaamheidscertificaten: RoHS
On Screen Display (OSD): Ja
Ondersteunde beveiligingsalgoritmen: 128-bit AES,802.1x RADIUS,HTTPS
Temperatuur bij opslag: -20 - 60 Ā°C
Relatieve luchtvochtigheid: 0 - 80 procent
Sneltoetsen: Ja
Snelle installatiehandleiding: Ja
Bedrijfstemperatuur, bereik: -4 - 140 Ā°F
(Buitenste) hoofdverpakking hoogte: 150.1 mm
(Buitenste) hoofdverpakking breedte: 595.1 mm
(Buitenste) hoofdverpakking brutogewicht: 17960 g
(Buitenste) hoofdverpakking lengte: 833.9 mm
Hoeveelheid per (buitenste) hoofdverpakking: 1 stuk(s)
Bedrijfstemperatuur (T-T): 0 - 40 Ā°C
Rekbevestigingspakket: Ja
Ingebouwde KVM schakelaar: Ja
Aantal KVM schakelaar ports: 16
Hoogte (in Rack Units): 1

Heb je hulp nodig?

Als je hulp nodig hebt met Tripp Lite NetCommander B070-016-19-IP2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Tripp Lite

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd