Owner’s Manual
APS-Series DC-to-AC
Inverter/Chargers
Models: APS2012, APS2424, APS3636VR,
APSINT2012, APSINT2424, APSINT3636VR
Introduction 2
Safety 2
Feature Identification 3
Operation 4
Configuration 5
Battery Selection 8
Mounting 9
Battery Connection 10
AC Input/Output Connection 11
Service/Maintenance 11
Troubleshooting 12
Warranty/Product Registration 13
Español 14
Français 27
40
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2019 Tripp Lite. All rights reserved. Isobar
® is a registered trademark of Tripp Lite.
PROTECT YOUR INVESTMENT!
Register your product for quicker service and ultimate peace of mind.
You could also win an ISOBAR6ULTRA surge protector—a $100 value!
www.tripplite.com/warranty
2
Important Safety Instructions
Introduction
SAVE THESE INSTRUCTIONS!
This manual contains important instructions and warnings that should be followed during the installation, operation and storage of this
product.
Location Warnings
Install your Inverter/Charger in a location or compartment that minimizes exposure to heat, dust, direct sunlight and moisture.
Although your Inverter/Charger is moisture resistant, it is NOT waterproof. Flooding the unit with water will cause it to short circuit and
could cause personal injury due to electric shock. Never immerse the unit, and avoid any area where standing water might accumulate.
Mounting should be in the driest location available.
Leave a minimum of 2” (50 mm) clearance at front and back of the Inverter/Charger for proper ventilation. To avoid automatic Inverter/
Charger shutdown due to overtemperature, any compartment that contains the Inverter/Charger must be properly ventilated with
adequate outside air flow. The heavier the load of connected equipment, the more heat will be generated by the unit.
Do not install the Inverter/Charger directly near magnetic storage media, as this may result in data corruption.
Do not install near flammable materials, fuel or chemicals.
Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously inhibit the
unit’s internal cooling, eventually causing product damage not covered under warranty.
Battery Connection Warnings
The battery should be connected before operating the Inverter/Charger.
Multiple battery systems must be comprised of batteries of identical voltage, age, amp-hour capacity and type.
Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated, your batteries should not be installed
(whether for a mobile or stationary application) in a “dead air” compartment. Ideally, any compartment would have some ventilation to
outside air.
Sparks may result during final battery connection. Always observe proper polarity as batteries are connected.
Do not allow objects to contact the two DC input terminals. Do not short or bridge these terminals together. Serious personal injury or
property damage could result.
Equipment Connection Warnings
Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of
the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the
presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.
Only connect your Inverter/Charger to a properly grounded hardwired AC power source. Do not plug the unit into itself; this will damage
the device and void your warranty.
You may experience uneven performance if you connect a surge suppressor, line conditioner or UPS system to the output of your Inverter/
Charger.
Operation Warnings
Your Inverter/Charger does not require routine maintenance. Do not open the device for any reason. There are no user serviceable parts
inside.
Potentially lethal voltages exist within the Inverter/Charger as long as the battery supply and/or AC input are connected. During any
service work, the battery supply and AC input connection (if any) should therefore be disconnected.
Do not connect or disconnect batteries while the Inverter/Charger is operating in either inverting or charging mode. Operating Mode
Switch should be in the DC OFF position. Dangerous arcing may result.
Caution: Your Inverter/Charger has a failsafe AC pass-through feature. The AC output will be live (if AC input is
available) even though the operating mode switch is set to DC OFF.
Congratulations! You’ve purchased the most advanced, feature-rich Inverter/Charger designed as an alternative energy source during utility
power failures. Tripp Lite APS Inverter/Chargers keep your equipment up and productive through all utility power problems (blackouts,
brownouts and overvoltages) by inverting DC power from user-supplied batteries into AC power. When utility power is present, APS Inverter/
Chargers automatically pass through power to your equipment while simultaneously recharging your connected battery bank. Built-in
Isobar® surge suppression provides an additional level of equipment protection. APS Inverter/Chargers are the quiet alternative to gas
generators for emergency backup applications. You get AC electricity anywhere and anytime you need it—with no fumes, fuel or noise!
3
Feature Identification
1 Configuration DIP Switches: Optimize Inverter/Charger
operation depending on your application. See Configuration
section for setting instructions.
2 Operating Mode Switch: Controls Inverter/Charger operation.
The “AUTO/REMOTE” setting ensures your equipment
receives constant, uninterrupted AC power. It also enables the
Inverter/Charger to be remotely monitored and controlled with
an optional remote module (Tripp Lite model APSRM4, sold
separately). The “CHARGE ONLY” setting allows your batteries
to return to full charge faster by turning the inverter off which
halts battery discharging. Setting the Operating Mode Switch
to the “DC OFF” (center) position will de-energize the unit and
connectAC OUT” to “AC IN.” See section for setting Operation
instructions.
3 “LINE”, “INVERT, “LOAD” LEDs: Intuitive “traffic light”
signals show whether the Inverter/Charger is operating from AC
line power or DC battery power. It also warns you if the
connected equipment load is too high. See section Operation
for instructions on reading the indicator lights.
4 “BATT VOLTAGE” LEDs: These three lights will turn on in
several sequences to show approximate battery level. See
Operation section for instructions on reading the indicator
lights.
5 DC Power Terminals: Connect to your battery terminals. See
Battery Connection section for instructions.
6 Hardwire AC Input/Output Terminals: Securely connect the
Inverter/Charger to vehicle or facility electrical system input
and output. See section for AC Input/Output Connection
instructions.
7 Resettable Circuit Breakers: Protect your Inverter/Charger
against damage due to overload or charger failure. See
Operation section for resetting instructions.
8 Remote Control Module Connector: Allows remote
monitoring and control with an optional module (Tripp Lite
model APSRM4, sold separately). See remote module owner’s
manual for connection instructions.
9 Battery Charge Conserver (Load Sense) Dial: Conserves
battery power by setting the low-load level at which the
Inverter/Chargers inverter automatically shuts off. See
Configuration section for setting instructions.
10 Multi-Speed Cooling Fan: Quiet, efficient fan prolongs
equipment service life.
11 Hardwire AC Input/Output Cover Plate
12 Battery Temperature Sensing Connector (side mounted,
not shown): Prolongs battery life by adjusting charge based on
battery temperature. Use with included cables (select models).
See section for details.Configuration
13 DC Power Terminal Cover Plate
14 Automatic Voltage Regulation (AVR) LEDs: (VR models only)
These lights will turn on as the Inverter/Charger automatically
corrects high or low AC line voltage without draining the battery.
Identify the premium features on your specic model and quickly locate instructions on how to maximize their use.
1
12
13
6
5
11
14 2
7
910 4 8 3


Product specificaties

Merk: Tripp Lite
Categorie: Niet gecategoriseerd
Model: APS INT2424

Heb je hulp nodig?

Als je hulp nodig hebt met Tripp Lite APS INT2424 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Tripp Lite

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd