TP Link TL-SF1006P Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor TP Link TL-SF1006P (3 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 230 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/3
Connection
© 2020 TP-Link 7106508699 REV1.0.0
Installation Guide
6-Port 10/100Mbps Desktop Switch with 4-Port PoE+
LED Explanation
Power
On: Power on
O: Power o
Note: 1. PoE ports can also connect to non-PoE devices, but only transmit data.
2. TL-SF1006P can supply up to 30 W for each PoE port and 67 W for all PoE ports.
Power
PoE MAX
PoE Max
On: 60 W≤Total power supply < 67 W
Flashing: Total power supply ≥ 67 W
O: Total power supply < 60 W
DC Power Adapter
AC Power Cord
Router
LAN Port WAN Port
Internet
Ethernet Ports (1-6)
PoE Ports (1-4)
IP Camera IP Phone
PoE Devices
AP
Link/Act and PoE Status
On: Link present but no activity
Flashing: Transmitting/receiving data
O: No link
On: Providing PoE power
Flashing: Current-overload/Short-circuit
O: Not providing PoE power
O: Port 1–4 run at 10/100 Mbps and support PoE power supply up to 100 m
away.
On: Port 1–4 run at 10 Mbps and support PoE power supply up to 250 m away.
Extend (Port 1–4)
O: All the ports transmit data in the same priority.
On: Port 1 and 2 transmit data in a higher priority than other ports. When
congestion occurs, packets which are transmitted by the ports with higher
priority occupy the whole bandwidth.
Priority (Port 1–2)
Switch Explanation
Network Video Recorder
Frequently Asked Questions (FAQ)
The Power LED should be lit when the power system is working normally. If the
Power LED is not lit, please try the following:
A1: Make sure the AC power cord is connected to the switch with power source
properly.
A2: Make sure the voltage of the power supply meets the requirements of the
input voltage of the switch.
A3: Make sure the power source is on.
Q1. Why is the Power LED not lit?
Please try the following:
A1: Make sure that the cable connectors are rmly plugged into the switch and
the device.
A2: Make sure the connected device is turned on and works normally.
A3: The cable must be less than 100 meters long (328 feet).
Q2. Why is the Link/Act LED not lit while a device is connected
to the corresponding port?
General Specications
Specications
Q3. Why are PoE ports not supplying power for PoE devices?
When the total power consumption of connected PoE devices exceeds the
maximum, the PoE port with a smaller port number has higher priority. The
system will cut o power to the ports with larger port numbers to ensure
supplying to other ports.
For example, if port 1, 2 and 4 are consuming 15.4 W respectively, and an
additional PoE device with 21 W is inserted to port 3, the system will cut o the
power of port 4 to compensate for the overload.
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
0 C to 40 C (32 F to 104˚ ˚ ˚ ˚F)
-40 C to 70 C (-40 F to 158˚ ˚ ˚ ˚F)
10% to 90%RH non-condensing
5% to 90%RH non-condensing
Environmental and Physical Specications
Продукт сертифіковано згідно с правилами системи УкрСЕПРО на відповідність вимогам
нормативних документів та вимогам, що передбачені чинними законодавчими актами
України.
Safety Information
Keep the device away from water, re, humidity or hot environments.
Do not attempt to disassemble, repair, or modify the device.
Do not use damaged charger or USB cable to charge the device.
Do not use any other chargers than those recommended.
Adapter shall be installed near the equipment and shall be easily accessible.
Place the device with its bottom surface downward.
Use only power supplies which are provided by manufacturer and in the origin packing of
this product. If you have any questions, please don’t hesitate to contact us.
TP-Link hereby declares that the device is in compliance with the essential requirements and other
relevant provisions of directives 2014/30/EU, 2014/35/EU, 2009/125/EC, 2011/65/EU and
(EU)2015/863.
The original EU declaration of conformity may be found at https://www.tp-link.com/en/ce.
EU Declaration of Conformity
PoE Disclaimer
The speed of the ports in extend mode will downgrade to 10 Mbps. The actual transmission
distance may vary due to power consumption of PoE-powered devices or the cable quality and
type.
PoE budget calculations are based on laboratory testing. Actual PoE power budget is not
guaranteed and will vary as a result of client limitations and environmental factors .
For technical support and other information, please visit
https://www.tp-link.com/support, or simply scan the QR code.
If you have any suggestions or needs on the product guides, welcome
to email techwriter@tp-link.com.cn.
To ask questions, find answers, and communicate with TP-Link users or
engineers, please visit https://community.tp-link.com to join TP-Link
Community.
Standard
Protocol
Interface
IEEE 802.3i, IEEE 802.3u, IEEE 802.3x, IEEE802.1p, IEEE
802.3af, IEEE 802.3at
CSMA/CD
6 10/100 Mbps RJ45 Ports, Auto-Negotiation MDI/MDIX
PoE Ports: Port 1-Port 4
PoE Power Budget: 67 W
Network Media (Cable)
10BASE-T: UTP category 3, 4, 5 cable (maximum 100 m);
EIA/TIA-568 100Ω STP (maximum 100 m)
100BASE-TX: UTP category 5, 5e cable (maximum 100 m);
EIA/TIA-568 100Ω STP (maximum 100 m)
Yes
94 mm
Wall Mountable
Distance Between
Mounting Holes
Switching Capacity
Power Supply
MAC Address Learning
Transfer Method
MAC Address Table
1.2 Gbps
2K
Store-and-Forward
Automatically learning, automatically aging
External Power Adapter
Input: 100-240 VAC, 50/60 Hz
Output: 53.5 VDC /1.31 A
Explanation of the symbols on the product label
DC voltage
RECYCLING
This product bears the selective sorting symbol for Waste electrical and
electronic equipment (WEEE). This means that this product must be handled
pursuant to European directive 2012/19/EU in order to be recycled or
dismantled to minimize its impact on the environment.
User has the choice to give his product to a competent recycling organization
or to the retailer when he buys a new electrical or electronic equipment.
Indoor use only
Polarity of output terminals
Energy eciency Marking (Level VI)
FCC compliance information statement
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause
undesired operation.
Any changes or modications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
We, TP-Link USA Corporation, has determined that the equipment shown as above has been
shown to comply with the applicable technical standards, FCC part 15. There is no unauthorized
change is made in the equipment and the equipment is properly maintained and operated.
Issue Date: 2020.3.9
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.• Reorient or relocate
the receiving antenna.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause
undesired operation.
Any changes or modications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
We, TP-Link USA Corporation, has determined that the equipment shown as above has been
shown to comply with the applicable technical standards, FCC part 15. There is no unauthorized
change is made in the equipment and the equipment is properly maintained and operated.
Issue Date: 2020.3.9
Product Name: I.T.E. POWER SUPPLY
Model Number: T535131-2-DT
Responsible party:
TP-Link USA Corporation, d/b/a TP-Link North America, Inc.
Address: 145 South State College Blvd. Suite 400, Brea, CA 92821
Website: https://www.tp-link.com/us/
Tel: +1 626 333 0234
Fax: +1 909 527 6803
E-mail: sales.usa@tp-link.com
FCC compliance information statement
Product Name: Gigabit Desktop Switch
Model Number: TL-SF1006P
Responsible party:
TP-Link USA Corporation, d/b/a TP-Link North America, Inc.
Address: 145 South State College Blvd. Suite 400, Brea, CA 92821
Website: https://www.tp-link.com/us/
Tel: +1 626 333 0234
Fax: +1 909 527 6803
E-mail: sales.usa@tp-link.com
Component Name Model
I.T.E. POWER SUPPLY T535131-2-DT
Mounting Requirements
To mount the device on a wall, use 2 screws which complies with ANSI B1.1 4#, (5#), 6#, 8#
standard and are more than 8.5 mm in length. When the screws are xed on the wall, the distance
between the screw head and the wall should be more than 1.5 mm.
Industry Canada Statement
CAN ICES-3 (A)/NMB-3(A)
This is a class A product. In a domestic environment, this product may cause radio interference,
in which case the user may be required to take adequate measures.
CE Mark Warning
請使用原裝電源供應器或只能按照本產品注明的電源類型使用本產品。
清潔本產品之前請先拔掉電源線。請勿使用液體、噴霧清潔劑或濕布進行清潔
注意防潮請勿將水或其他液體潑灑到本產品上。
插槽與開口供通風使用以確保本產品的操作可靠並防止過熱請勿堵塞或覆蓋開口。
請勿將本產品置放於靠近熱源的地方。除非有正常的通風否則不可放在密閉位置中。
請不要私自拆開機殼或自行維如產品有故障請與原廠或代理商聯繫。
BSMI Notice
安全諮詢及注意事項
限用物質含有情況標示聲明書
限用物質及其化學符號
Pb
Cd
Hg
六價鉻
Cr+6
多溴聯苯
PBB
多溴二苯醚
PBDE
產品元件名稱
PCB
外殼
電源供應器
備考1. “系指該項限用物質之百分比含量未超出百分比含量基準值。
備考2. “系指該項限用物質為排除項目。
Standard Diameter
ANSI B1.1 #4
ANSI B1.1 #8
ANSI B1.1 #6
ANSI B1.1 #5
2.845 mm
3.175 mm
4.166 mm
3.505 mm


Product specificaties

Merk: TP Link
Categorie: Niet gecategoriseerd
Model: TL-SF1006P
Kleur van het product: Zwart
Breedte: 158 mm
Diepte: 101 mm
Hoogte: 25 mm
Materiaal behuizing: Metaal
Stroom: 1.31 A
Vermogensverbruik (max): 74 W
DC voltage input: 53.5 V
Certificering: FCC, CE, RoHS
Netwerkstandaard: IEEE 802.3af, IEEE 802.3at
Temperatuur bij opslag: -40 - 70 °C
Luchtvochtigheid bij opslag: 5 - 90 procent
Rack-montage: Nee
Vermogenstoevoer inclusief: Ja
Auto MDI/MDI-X: Ja
Power over Ethernet (PoE): Ja
Stapelbaar: Nee
Switchingcapaciteit: 1.2 Gbit/s
MAC-adrestabel: 2000 entries
Switch type: Unmanaged
Aantal basis-switching RJ-45 Ethernet-poorten: 6
Type basis-switching RJ-45 Ethernet-poorten: Fast Ethernet (10/100)
Warmtedissipatie: 252.34 BTU/h
Auto-negotiation: Ja
Bedrijfstemperatuur (T-T): 0 - 40 °C
Relatieve vochtigheid in bedrijf (V-V): 10 - 90 procent
Code geharmoniseerd systeem (HS): 85176990
Aantal Power over Ethernet plus (PoE +)-poorten: 4
Fanloos: Ja
Store-and-forward: Ja
Ondersteundende kabel types: Cat3, Cat4, Cat5, Cat5e
MAC-adres zelfverouderende functie: Ja
MAC-adres zelflerende functie: Ja

Heb je hulp nodig?

Als je hulp nodig hebt met TP Link TL-SF1006P stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd TP Link

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Festo

Festo VPPI Handleiding

21 November 2024
Festo

Festo SFAB Handleiding

21 November 2024
Festo

Festo SFAH Handleiding

21 November 2024
Festo

Festo DRRD-12 Handleiding

21 November 2024
Festo

Festo SDE3 Handleiding

21 November 2024
Festo

Festo SFTE Handleiding

21 November 2024
Festo

Festo CRVZS-5 Handleiding

21 November 2024