SET UP
CLEAN YOUR STERILISER BEFORE FIRST USE - Refer to parts guide and diagram
1. Do not connect to power at this stage.
2. Remove all items from inside the steriliser base.
3. Pour exactly 80ml of water into the steriliser base.
4. Assemble the lower tray (A) with logo front facing and upper tray (B) and place in the steriliser base.
5. Add the lid.
6. Connect the lead and plug into the mains supply. Switch on at mains supply.
7. Press the play switch and it will light up amber to show the sterilising has begun.
8. The light will switch off when sterilising has ξΏnished.
9. Allow to cool for 5 minutes before turning off at the mains, removing the plug and steriliser lid.
10. Remove upper tray and lower tray, pour away any remaining water and wipe dry. Your steriliser is now ready to use.
This steriliser is designed for use with Tommee Tippee bottles and feeding accessories (except bottle brush).
The steriliser will hold a maximum of 6 Tommee Tippee bottles or a combination of fewer bottles plus
soothers and breast pump parts.
PARTS GUIDE
CLEANING
Unplug and allow to cool before cleaning. After each use pour away remaining water from the steriliser base by tipping
the steriliser sideways over a sink and wipe clean with a damp cloth only. Do not clean with abrasive cleaners or allow
to come into contact with solvents or harsh chemicals, damage could result.
DE-SCALING
The frequency of de-scaling should be as follows:
Hard water: 14 days
Medium: 21
Soft: 28
You can ξΏnd out your water quality via your water provider. FAQs and a picture of limescale can be found on our
website. After each use pour away remaining water from the unit base by tipping the unit sideways over a sink and
wipe with a damp cloth only. Unplug the unit and allow to cool before cleaning. A build up of limescale can negatively
affect the performance of the unit. We recommend carrying out the descaling process as per above frequency
guidelines to ensure the unit continues to work efξΏciently. Living in a hard water area can produce limescale quicker
than other areas therefore descaling is required sooner. Use a descaler that is suitable for use with stainless steel and
use as per the manufacturerβs guidelines. Alternatively you can use white vinegar or a descaling sachet to descale
your unit, please use as per manufacturerβs guidelines. Where no method is stated, 1 sachet to 200ml of hot water ratio
can be applied. See our website for detailed descaling method. Once you have descaled then follow instructions under
set up to perform a ξΏnal cleaning cycle. DO NOT use metal objects or scourers to clean your unit. DO NOT use bleach
or sterilising ξuid to clean the unit. DO NOT use abrasive or anti-bacterial materials. DO NOT scrub the heat plate.
TROUBLESHOOTING
Steriliser will not work
Check the mains lead is plugged into the unit and the mains socket is switched on. Check the fuse is in the plug (in
a UK plug only). Check the socket by plugging in another appliance. Check the appliance by plugging into another
socket.
Excessive steam
Check that items are correctly loaded in steriliser. Use exactly 80ml.
Bottles come out with a chalky mark
Steriliser needs descaling. Refer to Cleaning Instructions.
Cycle takes too long to complete
Too much water in steriliser. Use exactly 80ml.
a. Removable lower tray
b. Removable upper tray
c. Drying rack (parts a+b) with sterile surface
d. Locator for tommee tippee bottle neck
e. Locator for tommee tippee anti-colic valve (for
use if sterilising advanced anti-colic bottle)
f. Locator for bottle hood
g. Lid
h. Steriliser base
i. Lead with plug
j. Power button (play)
k. Stop button
l. Sterilising indicator light
m. Steam vents
n. 80ml measurement on Tommee Tippee bottle
o. Cable tidy
m
g
f
b
e
d
a
i
l
jk
h
ocn
INFORMATION ON THE DISPOSAL FOR WASTE ELECTRICAL & ELECTRONIC EQUIPMENT (WEEE)
This symbol on the products and accompanying documents means that used electrical and electronic products
should not be mixed with general household waste. For proper disposal for treatment, recovery and recycling, please
take these products to designated collection points where they will be accepted on a free of charge basis. In some
countries you may be able to return your products to your local retailer upon the purchase of a new product.
Disposing of this product correctly will help you save valuable resources and prevent any possible effects on human
health and the environment, which could otherwise arise from inappropriate waste handling. Please contact your local
authority for further details of your nearest collection point for WEEE.
Penalties may be applicable for the incorrect disposal of this product in accordance with national legislation.
The product is ξΏtted with a BS 1363 mains plug containing a fuse. If it ever becomes necessary to replace the fuse,
only use fuses that are marked BS 1362, and rated at 5A. In the unlikely event that this plug is not suitable for the
sockets in your home, it should be removed and a suitable plug ξΏtted as follows:
The wires of the mains lead are coloured in accordance with the following code:
GREEN AND YELLOW β EARTH
BLUE β NEUTRAL
BROWN β LIVE
As these colours may not correspond with the coloured markings sometimes used to identify the
terminals in the plug, connect as follows.
The wire coloured GREEN AND YELLOW must be connected to the terminal marked E or by the
earth symbol or coloured GREEN or GREEN AND YELLOW. The wire coloured BLUE must be
connected to the terminal marked N or coloured BLACK. The wire coloured BROWN must be
connected to the terminal marked L or coloured RED.
If you are in any doubt about how to wire a plug or replace a fuse safely, consult a qualiξΏed
electrician.
USAGE
Before sterilisation, wash all bottles and feeding accessories in warm soapy water or in a dishwasher (top rack only) to
remove any milk residues. Separate all components for washing and reassemble teat and screw ring for sterilising.
WARNINGS
MORE THAN 80ML OF WATER IN THE STERILISER BASE WILL PROLONG THE CYCLE TIME. LESS THAN
80ML MAY NOT STERILISE ITEMS PROPERLY. DURING STERILISATION HOT STEAM PASSES THROUGH THE
VENTS AT THE TOP OF THE UNIT. POSITION THIS UNIT AWAY FROM WALLS AND MAKE SURE IT IS NOT
UNDERNEATH ANY OVERHANGING SHELVES OR CABINETS. DO NOT OPEN THE STERILISER UNTIL THE
LIGHT HAS SWITCHED OFF, OR YOU HAVE PRESSED THE STOP BUTTON AND WAITED 5 MINUTES TO ALLOW
FOR COOLING.
1. Place on a ξat, heat resistant
work surface. Pour exactly 80ml
of water into the steriliser base.
Your Tommee Tippee bottles
have a handy 80ml measure.
4. Place the upper tray onto
the lower tray.
7. Place the lid onto the steriliser
base and plug the lead into the
mains power.
10. The stop button is there in case
you need to manually stop your
steriliser mid cycle. If you do this you
will have to restart the sterilising
process from the beginning as the
contents will not be sterilised.
13. Wash your hands thoroughly
before handling sterilised items.
Take care as the items may be
hot. Remove the sterilised
items. The teat tongs can be
used to remove the small items.
2. Assemble lower tray into the
steriliser base with logo facing
forwards on the right hand side.
5. Place the assembled teat and
screw ring onto the upper tray. It
is important not to have the
hoods ξΏtted onto the teat and
screw ring.
8. Press the play button to start
the machine. An amber light will
come on. This shows that the
steriliser is in its warm up phase
and will automatically begin the
sterilising phase when the
appropriate temperature is
reached.
11. After the cycle has ξΏnished
allow to cool for at least 5
minutes before opening the
steriliser. We recommend that
you hold the lid by the two side
handles, lift vertically until you
have cleared the upper tray then
tilt the lid to an angle away from
you to allow the water to drain.
14. The trays can be used separately
as a drying rack or sterile surface.
9. The light will automatically switch
off when the sterilising phase
has ξΏnished.
12. The contents will remain sterile
for 24 hours if the steriliser
is unopened.
15. To help in the reduction of
limescale, ensure that the unit is
drained and wiped after use once
fully cooled.
3. Place the bottles neck downwards
into the locators of the removable
tray. This includes locators for
advanced anti-colic valves.
6. Slot the hoods into the hood
locators of the removable upper
tray so that they hang over the
teat and screw ring but are not
fully assembled.
1
4 5 6
987
10 11 12
151413
2 3