Thermador PA48WLBH Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Thermador PA48WLBH (9 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 12 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/9
Professional Series Pro Harmony® Range Low Backguard Accessory
THERMADOR.COM
Installation
INSTRUCTIONS
THERMADOR.COM
Installation
INSTRUCTIONS
Professional Series Pro Harmony® Range Low Backguard Accessory
English................................................................................................ 2
Français .............................................................................................. 4
Español............................................................................................... 6
Models |
Modèles |
Modelos:
PA30GLBH
PA36GLBH
PA48GLBH
Page. 2
Safety
DEFINITIONS
9 WARNING
This indicates that death or serious injuries may occur
as a result of non-observance of this warning.
9 CAUTION
This indicates that minor or moderate injuries may
occur as a result of non-observance of this warning.
NOTICE: This indicates that damage to the appliance or
property may occur as a result of non-compliance with this
advisory.
Note: This alerts you to important information and/or tips.
Rear Clearance
REQUIREMENTS
To avoid staining on the back wall, high temperature,
non-porous construction materials suitable for use in a
cooking environment are recommended.
Models PCG305xx, PRD305xx, and PRD606xx are
suitable for 0'' rear clearance to combustible surfaces.
All Other Models:
When using the included Island Trim a minimum
6" (152 mm)* rear clearance is required to a
combustible surface*.
When installing against a combustible surface, a
Thermador® Low Backguard is required for a 0''
rear clearance to the combustible surface. A
Thermador Low Backguard must be purchased
separately.
A rear clearance to a surface covered in a non-
combustible material (metal, ceramic tile, brick,
marble, or stone)* is 0'' when using the included
Island Trim.
*Clearances of less than 6'' (152 mm) should be approved by the
local codes and/or by the local authority having jurisdiction.
Clearances from non-combustible materials are not part of the
ANSI Z21.1 scope and are not certified by CSA.
Installation
INSTRUCTIONS
Low Backguard Installation
For use with the following models:
State of California Proposition 65 Warning:
: WARNING
This product can expose you to chemicals including
vinyl chloride, which is known to the State of California
to cause cancer and birth defects or other
reproductive harm. For more information go to
www.P65Warnings.ca.gov.
9 WARNING
Fingers or hands could get pinched when installing
the backguard. Severe injury could result. Use
extreme caution and wear thick protective gloves to
avoid potential laceration to finger or hand while
sliding the backguard down onto the range.
9 WARNING
To avoid possible burn or fire hazard, a backguard
designed specifically for this appliance must be
installed whenever the appliance is used.
PRD304WHU/C PRG/L304WH
PRD305WHU/C PRG/L305WH
PRD364WDHU/C PRG/L364WDH
PRD364WLHU/C PRG/L364WLH
PRD366WHU/C PRG/L366WH
PRD484WCHU/C PRG/L486WDH
PRD486WDHU/C PRG/L486WLH
PRD486WLHU/C


Product specificaties

Merk: Thermador
Categorie: Niet gecategoriseerd
Model: PA48WLBH

Heb je hulp nodig?

Als je hulp nodig hebt met Thermador PA48WLBH stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Thermador

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd