Techno Line WS 9252 Handleiding
Techno Line
Weerstation
WS 9252
Lees hieronder de đź“– handleiding in het Nederlandse voor Techno Line WS 9252 (6 pagina's) in de categorie Weerstation. Deze handleiding was nuttig voor 32 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/6
Please read the instructions carefully and keep the manual well for future reference.
1. Remove the battery door of the main unit and transmitter.
2. Install 2 new AA size batteries for both main unit and transmitter, according to the polarity mark on
the battery compartment.
3. Replace the battery door.
4. After the batteries are installed, all LCD segment will be shown.
5. Press the “RESET” key of main unit first, and press the “RESET” key of transmitter.
6. It will automatically receive 433 MHz signal from transmitter for channel test in 8 seconds.
7. After 5 minutes channel test, it will turn to RC signal reception automatically.
8. Radio controlled function, the current time & date automatically synchronized with the time signal
transmitted from Germany(DCF77).
1. The unit can operate up to 3 remote transmitters.
2. Position the unit and transmitter within the effect transmission range: 50 meters in usual ive
circumstances.
3. In some cases, you may not receive the signal immediately, you can reset the unit and transmitter
again as described above.
1. LCD display
- Display of the time, alarm time, outdoor & indoor temperature & humidity and weather forecast.
2. SNOOZE / LIGHT key
- Press it to turn on backlight for 5 seconds.
- When the alarm is sounding, press it to stop the current alarm and activate snooze.
3. ALARM SET key
- Press it to display alarm time for 5 seconds. During alarm time displayed, press it to turn on/
off alarm function.
- Press and hold it for 3 seconds to enter alarm setting mode.
- In alarm setting mode, press it to step the setting item, and press it to save and exit the setting.
4. CH/+ key
- In normal mode, Press it to select channel 1 to channel 3.
- Press and hold it for 3 seconds to turn to channel auto-change mode. Press it again to return to
normal mode.
- In setting mode, press it to adjust the value of the flashing digit upwards. And press it without
releasing to speed up the setting.
5. MEM/- key
- In normal mode, press it to check the max./min. indoor and outdoor temperature record for 5
seconds.
- Press and hold it for 3 seconds to delete the max./min. temperature record.
- In setting mode, press it to adjust the value of the flashing digit downwards. And press it without
releasing to speed up the setting.
6. DISPLAY SET key
- In normal mode, press and hold it for 3 seconds to enter time setting mode.
- ime setting mode, press it to step the setting item, and press and hold it for 3 seconds to save and In t
exit the setting.
7. °C/°F slide switch
- Select temperature unit between °C/°F.
8. SENSOR key
- Press it to start 433 MHz channel test for main unit & transmitter.
- During the channel test, press and hold it for 3 seconds to manual turn off.
9. RCC key
- Press it to manual receive RC signal.
- During the RC reception, press and hold it for 3 seconds to turn off synchronisation.
10. RESET key
- In case of m -function, press it by using a metal wire to reset all the values. al
11. Battery door
1. LED indicator
- Flashes when the remote unit transmitting a reading.
- Display of the channel, temperature and humidity.
2.LCD display
3. CHANNEL slide switch
- Assign the transmitter to Channel 1, 2 or 3.
4. RESET key
- Press it to reset the transmitter.
5. Wall-mounting holder
- Use it to support the transmitter on the wall.
6. Battery compartment
The signal indicator flashing means time signals are being received. If the RC weather station receives
signal successfully, a sync-time symbol “ ” appears on the LCD. The unit has already received the
time signal. Otherwise, the signal strength symbol will disappear from the LCD display.
You may press “RCC” key to receive the time signal manually. The receive mode will be off
automatically after 6-16 minutes. Receive mode consumes more battery power that may reduce
battery lifetime.
The weather station has been programmed to automatically switch when daylight saving time is in
effect. Your weather station will display “DST” on the LCD during the summer.
If the weather station does not receive the time signal successfully, you can set the time manually. As
soon as the transmitter is received again, the clock will automatically synchronize with the received
time.
1. In normal mode, press and hold “DISPLAY SET” key for 3 seconds until the Hour format digit
flashing.
2. Press - “+” / “ ” key to select 12/24 hour format.
3. Press “DISPLAY SET” key again to step the setting item to Hour with the Hour digit flashing.
4. Press “+” / “ ” key to adjust the value of the- flashing digit.
5. Do the above operation in this sequence: 12/24 Hr > Hour > Minute > Second > Time difference.
6. Press and hold “DISPLAY SET” key for 3 seconds to save and exit the setting.
If your local time is different from the RC received time, you can set the desired time difference. The
available time difference is from -23 hours to +23 hours. After setting the desired time difference, the
weather station will show the time that RC received time plus/minus the time difference.
1. In normal mode, press and hold “ALARM SET” key for 3 seconds until the Hour digit flashing.
2. Press “+” / “ ” key to adjust the value of the- flashing digit.
3. Press “ALARM SET” key again to step the setting value to Minute with the Minute digit flashing.
4. Press “+” / “ ” key to adjust the value of the- flashing digit.
5. Press “ALARM SET” key to save and exit the setting.
1. In alarm mode, the “AL” icon will display on the LCD.
2. The alarm function will turn on automatically once you set the alarm time.
1. Set the desired alarm time as described in the above section.
2. Or press “ALARM SET” key to display the alarm time, press it again to turn on alarm function with
the alarm icon “ ” displayed on the LCD.
3. When weather station reach the alarm time, alarm sound ll start. Where, it can be stopped by wi
following operation:
a). Auto-stop after two minutes alarming if without any operation and it will re-alarm by the next day.
b). By pressing “SNOOZE” key to enter snooze that the alarm will sound again after 5 minutes.
Product specificaties
Merk: | Techno Line |
Categorie: | Weerstation |
Model: | WS 9252 |
Heb je hulp nodig?
Als je hulp nodig hebt met Techno Line WS 9252 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Weerstation Techno Line
3 December 2024
3 December 2024
3 December 2024
3 December 2024
3 December 2024
3 December 2024
3 December 2024
3 December 2024
3 December 2024
18 November 2024
Handleiding Weerstation
- Weerstation Braun
- Weerstation Daewoo
- Weerstation Honeywell
- Weerstation Ade
- Weerstation Adler
- Weerstation Alecto
- Weerstation Ascot
- Weerstation Auriol
- Weerstation Balance
- Weerstation Balance Meteo
- Weerstation Beurer
- Weerstation Blaupunkt
- Weerstation Brandson
- Weerstation Bresser
- Weerstation Brigmton
- Weerstation Daikin
- Weerstation Davis
- Weerstation Denver
- Weerstation Dexford
- Weerstation Digi-tech
- Weerstation DMV Electronics
- Weerstation Durabase
- Weerstation Ea2 LABS
- Weerstation Elgato
- Weerstation Elro
- Weerstation ELV
- Weerstation EQ-3
- Weerstation Eurochron
- Weerstation Extech
- Weerstation Fluke
- Weerstation Garni
- Weerstation Gira
- Weerstation GlobalTronics
- Weerstation Guardo
- Weerstation Hama
- Weerstation Hesdo
- Weerstation HomeMatic
- Weerstation Hyundai
- Weerstation Inovalley
- Weerstation Irox
- Weerstation IT
- Weerstation Konig
- Weerstation Krontaler
- Weerstation La Crosse
- Weerstation Lexibook
- Weerstation Livoo
- Weerstation Lowrance
- Weerstation Marquant
- Weerstation Meade
- Weerstation Mebus
- Weerstation Medisana
- Weerstation Minox
- Weerstation Muse
- Weerstation Nasa
- Weerstation National Geographic
- Weerstation Nedis
- Weerstation Netatmo
- Weerstation Nor-tec
- Weerstation Paget Trading
- Weerstation PCE Instruments
- Weerstation Perel
- Weerstation Prestigio
- Weerstation Profile
- Weerstation Pyle
- Weerstation Renkforce
- Weerstation Rocktrail
- Weerstation Saphir
- Weerstation Saxon
- Weerstation Sempre
- Weerstation Sencor
- Weerstation Soehnle
- Weerstation Solar
- Weerstation Steinberg
- Weerstation Tanita
- Weerstation Taylor
- Weerstation Technoline
- Weerstation Telefunken
- Weerstation TFA
- Weerstation Theben
- Weerstation Thierry Mugler
- Weerstation Thomson
- Weerstation Unitec
- Weerstation UPM
- Weerstation Velleman
- Weerstation Ventus
- Weerstation Vitek
- Weerstation Weinberger
- Weerstation Xeecom ApS
- Weerstation Ytora
- Weerstation Jacob Jensen
- Weerstation Jung
- Weerstation Optex
- Weerstation Oregon Scientific
- Weerstation Orion
- Weerstation Otio
- Weerstation Clas Ohlson
- Weerstation Camry
- Weerstation Clatronic
- Weerstation ECG
- Weerstation OBH Nordica
- Weerstation GoGEN
- Weerstation Goddess
- Weerstation EMOS
- Weerstation Cotech
- Weerstation Levenhuk
- Weerstation Cresta
- Weerstation Avidsen
- Weerstation Majestic
- Weerstation Prologue
- Weerstation Trevi
- Weerstation Day
- Weerstation Kemot
- Weerstation Chacon
- Weerstation AcuRite
- Weerstation Buienradar
- Weerstation La Crosse Technology
- Weerstation EVE
- Weerstation Waldbeck
- Weerstation EQ3
- Weerstation Homematic IP
- Weerstation EMOS SELECT
- Weerstation Uzoli
- Weerstation TFA Dostmann
- Weerstation Greisinger
- Weerstation Ease Electronicz
- Weerstation Rebel
- Weerstation PeakTech
- Weerstation YONO
- Weerstation JDC
- Weerstation Greenure
- Weerstation Chauvin Arnoux
- Weerstation ChiliTec
- Weerstation Global Water
- Weerstation Marathon
- Weerstation Gewiss
- Weerstation Browin
- Weerstation ClimeMET
- Weerstation Baldr
- Weerstation Setti+
- Weerstation Bearware
Nieuwste handleidingen voor Weerstation
15 December 2024
15 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024