Disposal of Electrical and Electronic Equipment in Private Households.
Disposal of used Electrical & Electronic Equipment (Applicable in the
European Union and other European countries with separate collection
systems)
This symbol indicates that this product shall not be treated as household waste.
Instead it shall be collected separately for the recycling of electrical and
electronic equipment.
If the new products are purchased, this product might be handed over to the distributor or
the collection system of waste electrical and electronic equipment eventually.
By ensuring this product is disposed of correctly, you will help prevent potential negative
consequences for the environment and human health, which could otherwise be caused by
inappropriate waste handling of this product or components of this product.
If this product is disposed illegally, it might cause a possibility of penalties. For more detailed
information about recycling of this product, please contact your local Civic Ofce, your
household waste disposal service or the shop where you purchased the product.
Thank you for purchasing this Tamron lens. Before using your new lens, please read the contents
of this Owner’s manual to properly use the lens. Also, it will be important to read the manual of the
camera to which you will attach the lens.
After reading, store this Owner’s manual in a safe place.
Please read also the document “Precautions for Safe Use of Tamron Lenses” supplied with the
lens for the detailed safety precautions to observe when using Tamron lenses.
•
Explains precautions that help to prevent problems.
•
Explains things you should know in addition to basic operations.
PART NAMES (Refer to Fig. )
①
Lens hood
②
Hood attaching alignment mark
③
Hood locking mark
④
Filter ring
⑤
Hood release mark
⑥
Focus ring
⑦
Focal length scale
⑧
Focal length mark
⑨
Zooming ring
⑩
Lens attachment mark
⑪
Lens-camera interface contacts
MAIN SPECIFICATIONS
Model B060
Focal Length 11-20 mm
Maximum Aperture F/2.8
Angle of View (diagonal) 105
˚
20
'
- 71
˚
35
'
Optical Construction 10/12
Minimum Object Distance( )MOD 0.15 m (5.9
"
) (Wide) / 0.24 m (9.4
"
) (Tele)
Maximum Magnication Ratio 1:4 (Wide MOD) / 1:7.6 (Tele MOD)
Filter Size
ø
67 mm
Length (minimum) 86.2 mm (3.4
"
) / Sony E, 86.5 mm (3.4
"
) / FUJIFILM X
Maximum Diameter
ø
73 mm
Weight 335 g (11.8 oz) / Sony E, 335 g (11.8 oz) / FUJIFILM X
Lens Hood HA046
•
Length : From front end of the lens to mount surface.
•
Specications, appearance, functionality, etc. are subject to change without prior notice.
ATTACHING AND REMOVING THE LENS
Remove the rear cap of the lens. Align the lens attachment mark
⑩
and mounting mark on the
camera, and then insert the lens.
Turn the lens clockwise until it locks.
To remove the lens, turn the lens in the opposite direction while pressing the lens release button
on the camera.
•
Turn off the power of the camera before attaching or removing the lens.
•
For details, please read the instruction manual of your camera.
SWITCHING FOCUS MODE
Select the desired focus mode on the camera.
For manual focusing, turn the focus ring
⑥
to acquire the desired focus.
For details, please read the instruction manual of your camera.
•
Under AF mode, there may be difculty for autofocus to work depending on the subject.
ZOOMING (Ref. Fig. )
Turn the zooming ring
⑨
to adjust the focal length (Zoom position) to a desired position.
LENS HOOD (Ref. Figs. ),
A bayonet-type lens hood
①
is provided as standard equipment.
We recommend shooting with the hood properly attached because the lens hood eliminates stray
light that may affect the picture.
■
Using the lens hood (Ref. Fig.
)
Align the hood attaching alignment mark
②
of the hood with the hood release mark
⑤
of the
lens.
Rotate the hood
①
in the direction of the arrow until the hood locking mark
③
meets the hood
release mark
⑤
.
■
Stowing the lens hood (Ref. Fig.
)
You can stow the lens hood
①
by attaching it in reverse.
Align the hood locking mark
③
of the hood with the hood release mark
⑤
of the lens.
Rotate the hood
①
in the direction of the arrow until the hood attaching alignment mark
②
meets the hood release mark
⑤
.
•
Be aware that the periphery of the photographed image may be darkened if the hood
①
is not
attached properly.
USAGE PRECAUTIONS
•
An internal focusing (IF) system is employed to reduce the minimum focus distance. The angle of
view may be wider than that of lenses with other focusing systems when shooting at a distance
less than innity.
•
The lens hood or the lens barrel may block the light from the ash. It is recommended to
perform trial shooting in advance.
•
Differences in the display systems of cameras may cause to show values different from the
maximum and minimum aperture values from the specications. This is not an indication of an
error.
•
Do not touch the lens-camera interface contacts with your ngers. Otherwise, it may cause a
malfunction.
•
If the temperature changes suddenly, condensation may form and cause malfunctions.
•
The front element is covered with stain-proof coating. After removing the dust on the lens
surface with a blower or another means, wipe it with a dry cloth.
•
Never use benzene, thinner, or other organic solvents to clean the lens.
•
Store the lens in a clean and well-ventilated place.
•
For more details on the lens cleaning and storage, the compatibility with cameras, and other
support information see our website. https://www.tamron.jp/en/support/