Superior Pump 92341 Handleiding


Lees hieronder de πŸ“– handleiding in het Nederlandse voor Superior Pump 92341 (4 pagina's) in de categorie Pomp. Deze handleiding was nuttig voor 39 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
LIMITED WARRANTY AND LIMITATION OF LIABILITY
Decko Products warrants this product free from material and/or manufacturing defects for one
year from date of purchase (three years on select cast iron pumps). As the sole and exclusive
remedy for a breach of this limited warranty, if the product is found by Decko Products to be
defective, Decko Products, at its option, will refund the purchase price or replace the product
with an equivalent product if it is returned to the place of purchase or returned postpaid to
Decko Products, ATTN: Warranty Dept., 2301 Traffic St. NE, Minneapolis, MN 55413, with
proof of purchase. Any disassembly, modification, or abuse of this product voids this limited
warranty. This product is not designed for pumping flammable or corrosive fluids, and use of
this product to pump such materials also voids this limited warranty
DECKO PRODUCTS DISCLAIMS ALL OTHER
EXPRESS OR IMPLIED WARRANTIES,
INCLUDING WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
IMPORTANT NOTICE: Some commercial and residential insurance policies extend coverage
for damages incurred by product failure. In most cases, you will need to have possession of
the product to support your claim. In the case where you need to retain possession of the
product to support a damage claim you submit to your insurance company, Decko Products
will exchange the unit or refund the original price once the claim is settled with the insurer.
www.superiorpumpco.com
Superior Sump Manual Revised 10/08
If for any reason you have questions concerning your new Superior Pump, call us toll free at
1-800-495-9278, or contact us on the web at www.superiorpumpco.com
Carefully read and understand all of the Warnings and installation instructions in this
manual. Failure to follow these instructions could lead to serious bodily injury and/or
property damage. Retain these instructions for future reference.
This pump has been manufactured with your needs in mind. Properly installed in the right
application, your new Superior Pump will give you years of carefree performance.
DANGER Water and electricity can be dangerous if certain precautions are not adhered
to. This pump is designed to operate perfectly safe in a water environment; however,
improper use and installation can result in personal harm from electrical shock. Please pay
attention to the following warnings.
WARNING
Never touch any electrical device, including this pump, when it is touching water, in water, or
even in a moist environment. Always unplug (disconnect the electricity) when working on or
installing the unit.
WARNING
RISK OF ELECTRICAL SHOCK. This pump is supplied with a grounding conductor and
grounding-type attachment plug. To reduce the risk of electrical shock, be certain that it is
connected only to a properly grounded, grounding-type receptacle.
WARNING Do not use the power cord or discharge hose to carry or handle the pump.
Doing so may cause damage to the power cord or discharge hose. Use the carrying handle
supplied with the pump.
WARNING Always use a grounded outlet. A three-prong mating type receptacle is
required for safe use. This should be in accordance with the National Electric Code and any
additional codes or laws required by your local government.
NOTICE It is strongly recommended to use a ground fault interrupt device on any
electrical appliance, including this pump, when used in a wet or moist environment as it
provides a much safer installation and will greatly reduce possible injury from electrical shock.
This is required by many local codes and enforcement agencies.
REPLACEMENT PARTS
To order replacement parts,
Call 1-800-495-9278
1
4
2
3
5
6
7
8
9
1
2
4
5
6
7
8
10
10
11
2 7
Ref Description
PARTS FOR MODEL#
92250
92255
92260
92251
92257
92330
92342
92335
92331
92341
92337
92351
92501
92507
92352
92511
1 Power Cord 99008
99008
2 Handle 99050
99051
99050
99051
99051
99051
3 Hose Coupling/Adapter 99007
99007
99007
4 Oil Fill Plug with O-ring 99056
99056
99056
99056
99056
99056
5 Shaft Seal 99057
99057
99057
99057
99057
99057
6 Impeller 99060
99087
99065
99096
99070
99070
7 Gasket 99062
99062
99062
99088
99064
99064
8 Volute/Base 99067
99078
99069
99078
99071
99071
9 Intake Screen 99073
99076
99073
99076 99074 99074
10 Float Switch
92000
92000
92000
92000
92000
92010 92000
92005 92010
92010
92000
92010
92005
92005
92005
11 Vertical float Switch Bracket
N/A
N/A
N/A
N/A
N/A
99105 N/A
N/A 99105
99105
N/A
99105
N/A
N/A
N/A
NOTICE Height and/or piping restriction will reduce the pump output performance. See
the performance chart below to insure you have the proper pump for your application.
Whenever possible use the same size or larger pipe as the pump discharge for optimum
performance. Reducing the pipe size will not harm your pump; it will just reduce the output.
PERFORMANCES
Model #
Output in gallons per minute at listed discharge
height above pumping level
0’ 5’ 10’ 15’ 20’ 25’
92250, 92251, 92260, 92255, 92257 30 22 20 16 9 2
92330, 92342, 92335 40 34 28 22 12 2
92331, 92337, 92341 46 36 30 25 12 1
92351, 92352 60 56 50 35 15 6
92501, 92511, 92507 70 66 58 48 25 10
SPECIFICATIONS
Power supply requirements 120V, 60 Hz (15 amp)
Motor Continuous Duty, Capacitor Start,
Thermally Protected
Liquid Temperature Range 32Β° F - 120Β° F (0Β° C - 49Β° C)
DANGER Do not use this pump to pump chemicals, flammable liquids, sewage or
corrosive liquids. You could injure yourself and the pump will fail. Pumping these types of
liquids voids the warranty. Decko Products manufactures pumps for these types of liquids.
Make sure you purchase a pump designed for your specific needs. This pump will handle
fluids with the same characteristics as water. If you have any questions call us at
1-800-495-9278 or contact us on the web at www.superiorpumpco.com
WARNING
Your pump has thermal over-load protection built in. It is not recommended for pumping
liquids over 120ο‚° F. The thermal overload protector will automatically shut down the pump in
an overheat situation. It will then reset itself once the pump cools down. This overload is
designed as a safety device and it will fail after repeated use. Normal operation is for fluids
between 32ο‚° F & 120ο‚° F.
DO NOT RUN THE PUMP DRY. The pump depends on water for cooling and lubrication.
Operating the pump without water may cause the motor to overheat or cause damage to parts
of the pump. It may also shorten the life of your pump.
NOTICE
EXTENSION CORDS
For best performance, it is recommended to connect the power cord directly to the grounded
GFCI outlet. If the use of an extension cord is necessary, always use a grounded waterproof
type cord. Never use longer than a 25-ft. cord that is lighter than 14/3 gauge.
DANGER Keep all electrical connections away from wet and moist environments. Wet
connections can cause electrical shock resulting in personal injury.
USE AND INSTALLATION
WARNING A ,LWAYS DISCONNECT THE POWER SOURCE BEFORE ATTEMPTING TO INSTALL
SERVICE OR PERFORM MAINTENANCE ON THE PUMP
. FAILURE TO DO SO MAY RESULT IN FATAL
ELECTRICAL SHOCK.
Your Superior Pump is designed and built to give you reliable performance and long life. It will
pump water automatically for years when properly installed in the right environment.
REMOVING OLD PUMP. (If necessary)
1. Make sure power supply is disconnected.
2. After the power is off, remove the old pump. There are many different possible
types of installations.
3. It is best to remove all old piping and start over with new piping. Be sure to clean all
debris and dirt out of the sump basin before installing your new pump.
Be sure to have a grounded 120V AC outlet mounted within 6 ft. of your sump basin. Again, it
is highly recommended that a GFCI (ground fault circuit interrupter) outlet be installed in the
receptacle box.
NOTICE A qualified electrician must perform all wiring.
Model #
92250
92255
92260
92251
92257
92330
92342
92335
92331
92341
92337
92351
92352
92501
92511
92507
HP 1/4 1/4 1/3 .3 1/3 1/2
Amps 3.82 3.82 4.1 4.1 7.6 7.6
Solids Handling 1/8” 1/8” 1/8” 3/8” 1/2” 1/2”
Warranty
(Years) 1 3 1 3 3 3
Discharge Size 1 ¼” 1 ¼” 1 ¼” 1 ½” 1 ½” 1 ½”
6 3


Product specificaties

Merk: Superior Pump
Categorie: Pomp
Model: 92341

Heb je hulp nodig?

Als je hulp nodig hebt met Superior Pump 92341 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Pomp Superior Pump

Handleiding Pomp