Instruction Manual
2
INTRODUCTION / TECHNICAL DATA
Congratulations on purchasing your SUNTEC WELLNESS KLIMATRONIC
Ā®
TRANSFORM unit.
Your air-conditioner has been developed and manufactured in accordance with standards of state of the art
technology.
Please read the operating instructions carefully before connecting your TRANSFORM unit to the power
supply in order to prevent damage from improper use. Pay special attention to the safety instructions. If you
pass this TRANSFORM unit on to a third party, you must also include these operating instructions. Please
keep these operating instructions in a safe place for any questions which may arise in future.
Thank you for showing confidence in our product. We hope you enjoy a pleasant room climate with your
Suntec air-conditioner.
MODEL TRANSFORM
7000
TRANSFORM
9000
TRANSFORM
10500
TRANSFORM
12000
TRANSFORM
14000
VOLT 230V 50Hz AC 230V 50Hz AC 230V 50Hz AC 230V 50Hz AC 230V 50Hz AC
POWER CONSUMPTION (W) 760 W 990 W 1150 W 1340 W 1530 W
(Wb24 /Db35)
POWER CONSUMPTION (W)
COOLING 900 W 1100 W 1280 W 1480 W 1700 W
HEATING
(EN60335)
700 W 950 W 1100 W 1300 W 1500 W
COOLING CAPACITY 2.000 W 2.600 W 3.000 W 3.500 W 4.000 W
HEATING CAPACITY 2.000 W 2.600 W 3.000 W 3.500 W 4.000 W
(Wb24 / Db35)
DEHUMIDIFICATION
CAPACITY
(30, RH80%)
30L/day 50L/day 50L/day 60L/day 70L/day
NOISE 50dB(A) 51 dB(A) 52dB(A) 53dB(A) 54dB(A)
AIR CIRCULATION [mĀ³/h] 360 400 420 450 450
COOLING AGENT R410a R410a R410a R410a R410a
REMOTE CONTROL INCLUSIVE INCLUSIVE INCLUSIVE INCLUSIVE INCLUSIVE
TIME SWITCH 0-24 STD 0-24 STD 0-24 STD 0-24 STD 0-24 STD
DIMENSIONS (mm) WXDXH 300x480x630 300x480x630 300x505x778 300x505x778 300x505x778
NET WEIGHT 24 kg 25 kg 28 kg 29.5 kg 30,5 kg
All figures are approx. data. Characteristics pursuant to current Norm EN 14511. Subject to alterations.
EASY TO OPERATE AND EASY TO MOVE AROUND
ī€ The TRANSFORM unit can be moved easily on rollers from room to room.
ī€ The air quantity can be adjusted via up to three ventilation levels.
ī€ The air ļ¬‚ow can be very strong and reach up to 5 or 6 metres.
ī€ Installation by a specialist is not required
ī€ Simply plug into a normal household socket with an operating voltage of 230V/ 50Hz.
ī€ The extract air hose can be stored in the TRANSFORM unit for transport and when not in use.
ī€ This Suntec TRANSFORM unit operates in accordance with the heat pump principle. On account of the
special, innovative construction of the TRANSFORM unit, its heating function is extremely eļ¬ƒcient
compared to conventional heating units.
SCOPE OF DELIVERY
1 x TRANSFORM unit
1 x remote control
1 x air hose 150 cm
1 x air hose connector
1 x bracket air hose
1 x sir outlet grid
1 x coarse filter top, 1 coarse ļ¬lter
bottom
1 x activated carbon ļ¬lter top
1 x operating instructions
1 x drainage hose 50 cm
2 x sealing plug
3
BEFORE INITIATION
1. To avoid damage, place the TRANSFORM unit in an upright position for at least 24 hours
before initiation.
2. Release the holder air hose in the TRANSFORM unit and take out the extract air hose.
3. Fasten the air hose before initiating the TRANSFORM unit.
4. Turn the extract air hose in the direction of the arrow (1) displayed and remove it from the
TRANSFORM unit.
5. Turn the extract air hose in the direction of the arrow (2) displayed and connect it to the
TRANSFORM unit.
6. Plug the power plug into a socket. Never pull the plug out of the socket with force using the
connection line. This can damage the power cable.
7. Since the TRANSFORM unit emits hot air, please observe a suļ¬€icient minimum safety
distance to each wall. (Fig. 1)
8. Despite the splash water protection, you should not operate the TRANSFORM unit in moist
areas, such as e.g. swimming baths or similar areas.
9. The colour of the TRANSFORM unit can change slightly due to direct solar radiation.
10. The TRANSFORM unit is equipped with a special thermal deactivation. This protects the unit
from overheating in extreme ambient conditions.
11. Please place the TRANSFORM unit so that the air inlet is not impeded, e.g. by furniture or
curtains, since this can negatively eļ¬€ect the capacity.
12. Do not allow direct sunlight to shine on the TRANSFORM unit, since it may then overheat and
automatically deactivate on account of the thermal deactivation.


Product specificaties

Merk: Suntec
Categorie: Airco
Model: Transform 10500
Kleur van het product: Wit
Timer: Ja
Gewicht: 28000 g
Breedte: 300 mm
Diepte: 505 mm
Hoogte: 778 mm
Netbelasting: 1150 W
Geluidsniveau: 52 dB
Air conditioner functies: Cooling, Dehumidifying, Heating
Jaarlijks energieverbruik (koelen): 575 kWu
Energie-efficiƫntieklasse (koeling): A
Luchtfilter: Ja
Op afstand bedienbaar: Ja
Energieverbruik per uur (koeling): - kWu
Ontvochtiging capaciteit: 2.08 L/u
Luchtstroom (hoge snelheid): 420 mĀ³/uur
Koelcapaciteit (max): - BTU/h
Koel capaciteit in watt (max): 1280 W
Verwarmingscapaciteit in watt (max): 1100 W
Energie-efficiƫntieklasse (verwarming): A
AC-ingangsspanning: 230 V
AC-ingangsfrequentie: 50 Hz
Timerduur (maximum): 24 uur

Heb je hulp nodig?

Als je hulp nodig hebt met Suntec Transform 10500 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Suntec

Handleiding Airco

Nieuwste handleidingen voor Airco

Haier

Haier QPFA10 Handleiding

5 November 2024
Haier

Haier QHC18 Handleiding

5 November 2024
Haier

Haier HWR05XCR Handleiding

5 November 2024
Haier

Haier QHM15 Handleiding

5 November 2024
Haier

Haier HPFD12XHP Handleiding

5 November 2024
Haier

Haier QHM18 Handleiding

5 November 2024
Haier

Haier QHM10 Handleiding

5 November 2024
Haier

Haier QPSA13 Handleiding

5 November 2024
LG

LG C142CM Handleiding

4 November 2024