Write odel and Serial Numbers M
here:
Model _____________________ :
Serial No. __________________ :
RANGE HOOD
M els: od
H24RSS
H24 CVSS
H24ADASS
H30RSS
H30 CVSS
H30ADASS
H36RSS
H36 CVSS
H36ADASS
H24RW
H24WCV
H24ADAW
H24RB
H24BCV
H24ADAB
H30RW
H30WCV
H30ADAW
H30RB
H30BCV
H30ADAB
H36RW
H36WCV
H36ADAW
H36RB
H36BCV
H36ADAB
User Manual
BEFORE USE, PLEASE READ AND FO OW A SAFETY RULES AND OPERATING LL LL
INSTRUCTIONS
Cod:0103091380-00.01
Felix Storch, Inc.
Summit Appliance Division
An ISO 9001:2015 registered company
770 Garrison Avenue Bronx, New York 10474
www.summitappliance.com
2
TABLE OF CONTENTS
Equipment Safety 3-4
Cooking Safety Information 4
Installation Instructions 5- 13
Ductwork Requirements 5
Exhaust Connection 5
Maximum Duct Length 5
Damage 5
Wiring Connection 6
Ductwork Length Worksheet 7
Choosing a Vent Option 8
Duct Installation 8- 10
Mark Holes - 11 12
Cut Holes 12
Secure the Hood 13
Connect the Ductwork (Ducted Installations) 13
Replace the Filter 14
Operating your Range Hood 14
Cleaning and Care 15- 16
Reusable Metal Grease Filter Ducted Installations 15
Charcoal Filter Recirculating Installations 15
Surfaces 16
Troubleshooting 16
Limited Warranty 18
3
EQUIPMENT SAFETY
WARNING: To reduce the risk of fire, electric shock, or injury to persons, observe the following:
Use this unit only the manner intended the in by
manufacture you have questions, contact r. If any
the manufacturer.
Before servicing cleaning unit, switch power off or at
service panel lock service disconnecting means and
to prevent power from being switched on
accidentally. When service disconnecting means the
cannot locked, securely fasten a prominent be
warning device, such a tag, the service panel. as to
Installation work and electrical wiring must be done
by qualified person(s) accordance with all in
applicable codes and standards, including fire-rated
construction.
Sufficient air is needed for proper combustion and
exhaustion of gases through the flue (chimney) of
fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturer’s
guideline and safety standards such those as
published the National Fire Protection Association by
(NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
When cutting drilling into a wall ceiling, not or or do
damage electrical wiring other hidden utilities. and
Ducted fans must always vented outdoors. be to the
WARNING: FUEL (GAS) BURNING RANGES MUST BE
VENTED OUTDOORS USING, MINIMUM, METAL AT
DUCTWORK AND RANGE HOODS SUFFICIENT CAPACITY. OF
• manufacturer’s Follow your fuel burning equipment guidelines, well as, all applicable safety as
standards published the National Fire Protection Association (NFPA), American Society by and the
for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and your local code authorities.