Your Guarantee
IF THIS PRODUCT IS FOUND TO BE FAULTY AS A RESULT OF FAULTY
MATERIALS OR WORKMANSHIP WITHIN ONE YEAR FROM DATE OF
PURCHASE, IT WILL BE REPAIRED FREE OF CHARGE.
This guarantee is subject to the following terms:
Sunpentown must be notied of the fault.
Proof of purchase must be presented to Sunpentown’s nominated
representative.
The warranty will be void if the product if modied, misused or repaired by
an unauthorized person.
The warranty after repair will not be extended beyond the original one-year
period.
All replacement parts will be new or reconditioned.
Parts, which are replaced, become the property of Sunpentown.
The warranty applies for the use of the product in the USA only.
WHAT IS NOT COVERED:
Warranty does not include freight charges.
Incidental or consequential damage caused by possible defects with this
product.
Damage to product caused by improper power supply voltage, accident, re,
oods or acts of nature.
Failure of product resulting from unauthorized modications to the product.
Improper installation or failure to perform the necessary maintenance.
This GUARANTEE is in addition to your Statutory Rights
SUNPENTOWN INTERNATIONAL INC.
Tel: 626- -2299 Fax:626- -7116 336 336
14625 Clark Ave., City of Industry CA 91745
service@sunpentown.com
www.sunpentown.com
Warm/Cool Mist Humidifier
With Night Light
READ AND SAVE THESE IMPORTANT INSTRUCTIONS
Model SU-2628B
WHEN USING ELECTRICAL APPLIANCES, BASIC SAFETY PRECAUTIONS
SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTR IC
SHOCK, AND INJURY TO RSONS, INCLUDING THE FOLLOWING: PE
1. Check the household voltage to ensure it matches the unit s rated specication
before operating.
2. NEVER place the humidier in an area where it is accessible to children.
NEVER use the humidier in an enclosed room, particularly where a child may
be sleeping, resting, or playing.
3. DO NOT add water from mist outlet directly, or it will damage the unit.
4. Do not allow children to play with any product packaging, such as plastic bags.
5. To avoid re hazard, NEVER put the cord under rugs, near heat registers,
radiator, stoves, or heaters.
6. DO NOT place the humidier near heat sources such as stoves, radiators, and
heaters. Do locate your humidier on an inside wall near an electrical outlet.
The humidier should be at least 4 away from the wall for best results.
7. Do not attempt to rell the humidier without rst unplugging the unit from its
electrical outlet.
8. DO NOT operate any appliance with a damaged cord or plug, after the
appliance malfunctions, or if it has been dropped or damaged in any manner.
Return appliance to manufacturer for examination, electrical or mechanical
adjustment, or repair.
9. Always place the humidier on a firm, at, level surface at least above from 20
the oor.
10. DO NOT allow the mist outlet to directly face the wall.
11. NEVER tilt, move, or attempt to empty unit while it is operating.
12. Shut o and unplug before removing the water tank and moving the unit.
13. DO NOT attempt to repair or adjust any electrical or mechanical functions on
this unit. Doing so will void your warranty. The inside of the unit contains no user
serviceable parts. All servicing should be performed by qualied personnel only.
14. Do not plug in the cord with wet hands: electric shock could result.
15. NEVER use detergents, gasoline, glass cleaner, furniture polish, and paint
thinner, or other household solvents to clean any part of the humidier.
16. Do not pour water in any openings other than the water tank.
17. Excessive humidity in a room can cause water condensation on windows and
some furniture. If this happens, turn the humidier OFF.
18. Never immerse the humidier in water or expose to excessive liquid.
STORING THE HUMIDIFIER
1. Follow the 3 steps in the weekly maintenance.
2. Preferably store the humidier in its original box.
3. Avoid high temperature or direct sunlight.
TROUBLE SHOOTING
If your humidier is not working correctly, please check the following causes:
TROUBLE
PROBABLE CAUSE
Humidier does not
operate.
Power cable not plugged in
The power light is , but on
there is no mist with wind
No water in water tank
The water mist produces
an unpleasant smell.
New machine.
Dirty water or the water is
left in the water tank for too
long.
The power light is on, but
the humidier doesn’t
work
Too much water in the
water basin
The output volume of the
mist is low
The transducer is dirty.
Water is too dirty or water
kept too long in the tank
Abnormal noise
Resonant in water tank
when water is too less
Unit is on an unstable
surface
Can t remove the tank
cap
Over tightened
6
1
REPLACING THE FILTER CARTRIDGE
It is recommended to replace the ion exchange lter approximately every 1,000
hours of use or about 260 gallons of water depending on the condition of water you
are using.
REPLACEMENT INSTRUCIONS
1. Remove the water tank cap from the water tank.
2. The ion exchange lter is attached on the water tank cap. Detach the old ion
exchange lter by turning counter-clockwise. (Fig.1)
3. Attach the new ion exchange lter to the cap by turning clockwise. (Fig.1)
ATTENTION:
If condensate forms on your windows or walls, please turn o the humidier.
CLEANING AND MAINTENANCE
To get the most of the benets from humidier, follow the instructions below the
carefully.
DAILY MAINTENANCE
1. Turn o the humidier and unplug it from the electrical outlet.
2. Remove the water tank.
3. Drain and rinse the water tank.
4. Wipe and dry the tank and the base with clean soft cloth or paper towel.
WEEKLY MAINTENANCE
1. Follow the 4 steps in the daily maintenance.
2. Fill the basin of the base with one cup of white vinegar for about 15 minutes.
3. Discard the vinegar and gently wipe o the deposit in the basin, with soft cloth.
You may use a soft brush for cleaning as well.
CONSUMER SAFETY INFORMATION
Note: This is an electrical appliance and requires attention when in use.
Note: If condensate forms on the walls or windows of the room, turn o the
humidier. The room already has plenty of humidity and additional moisture may
cause damage. Do not block air inlet or outlet.
CORD AND PLUG INSTALLATION SAFETY INSTRUCTIONS
The length of cord used on this appliance was selected to reduce the hazards of
becoming tangled in, or tripping over a longer cord. If a longer cord is necessary an
approved extension cord may be used. The electrical rating of the extension cord
must be equal to or greater than the rating of the humidier. Care must be taken to
arrange the extension cord so that it will not drape over the countertop or tabletop
where it can be pulled on by children or accidentally tripped over.
MAIN FEATURES
·Built-in heating element for warm mist
·Ion exchange lter to reduce mineral deposit
·Easy use adjustable moisture dial
·7-color night light with adjustable brightness
·Transparent water tank with built-in carrying handle
·Automatic out of water shut-o protection
SPECIFICATIONS
·Coverage area: 430 to 538 Cu.Ft. (40 to 50 m2)
·Input voltage: 120V/50Hz~60Hz
·Moisture ouput 350ml/h (11.8oz) :
·Water tank capacity 7L (1.8Gallon/236oz) :
·Rated power: W (Cool Mist), 1 W (Warm Mist) 30 30
·Weight: Approx 4.4lbs (empty)
·Dimension: 12.75 (L) x 7.78 (W) x (H) 13.58