Speco Technologies AWRR44 Handleiding


Lees hieronder de šŸ“– handleiding in het Nederlandse voor Speco Technologies AWRR44 (2 pagina's) in de categorie Toegangscontrolesysteem. Deze handleiding was nuttig voor 47 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
This Quick Start Guide is intended for experienced installing technicians. It is a basic reference to ensure all connections are properly made.
Installation and wiring of systems must be in accordance with the National Electrical Code, ANSI/NFPA 70.
1.0 Introduction
Long-Range Transmitters and Receivers with an integrated receive antenna comprise this high frequency, long-range identiļ¬cation solution.
Intended for security access control applications, AWRR44ā€™s wireless communications are based upon a secure, digital, anti-playback routine.
The four-channel Receiver (Channels A, B, C & D), model AWRR44, allows Transmitter data to be sent over four separate Wiegand outputs.
Formatting of the Wiegand output is dependent upon the data encoded on each individual Transmitter.
2.0 Receiver Layout
3.0 Cable Requirements
24 AWG minimum, multi-conductor stranded with an overall foil shield, for example Belden 9540 or similar. Per the SIAā€™s Wiegand speciļ¬cation,
maximum cable length is 500 feet (152.4 m).
4.0 Output Formats
Wiegand (industry standard 26-bit Wiegand and custom Wiegand formats).
5.0 Grounding
Shield (drain) continuity must run from the Receiver to the access panel. Shield and reader ground must be tied together at the access panel and
connect then to an earth ground at one point.
6.0 Power
Power required is 12 VDC nominal at 120mA. The Receiver may be powered by the access panel. A linear power supply is recommended for
best operation.
7.0 Mounting
The Receiver may be mounted indoors or outdoors. The base of the enclosure includes a drill template providing mounting provisions to a wall box
(standard North American and European), as well as pre-drilled holes in the four corners allowing mounting to a ļ¬‚at surface. Use supplied #6
mounting screws, or equivalent security screws, for installation.
8.0 Read Range Adjustment
As shipped, the Receiver is set for the maximum read range, which is nominally up to 200 feet (61 m). This may be reduced by adjusting the
range pot in the counter-clockwise direction. Additionally, for optimal read range it is important that the Receiver be mounted as far from
potential interference sources as possible. These sources may include, but are not limited to, large metal obstructions, as well as magnetic ļ¬elds
and radio transmissions. Note for each installation, read range may vary.
Legend:
a. Antenna Connector
b. Audio Beeper
c. 10-PIN Terminal Block
d. Read Range Adjustment
e. Antenna Switch
f. Beeper Switch
QUICK START GUIDE
AWRR44 LONG-RANGE
433-MHz RECEIVER
P/N: 01672-101 āˆ™ Rev. 09.19
9.0 External LED Indicator
Refer to the information below for explanation on the Receiverā€™s external LED indicator operation:
Green: Initial power up
Amber: Normal powered on state
Flash Green: An activated Transmitter button press has been received and processed
Flash Red: A non-activated Transmitter button press has been detected
Off: Receiver is not powered on, or failed to power up successfully
10.0 Antenna Switch
As shipped, the Receiverā€™s Antenna Switch is set in the INT position. Read range can be extended using a separate dipole antenna attached to
Receiverā€™s on-board SMA connector. If a separate antenna is used, then the switch should be set in the EXT position.
11.0 Beeper Switch
As shipped, the Receiverā€™s Beeper Switch is set in the ON position. If the installation technician prefers to disable the beeper and External LED
Indicator, then the Beeper Switch should be set in the OFF position.
12.0 10-Pin Terminal Block
Refer to the information below for cabling to the Receiver:
AD0: Button One, Wiegand Data 0, Channel A.
AD1: Button One, Wiegand Data 1, Channel A.
BD0: Button Two, Wiegand Data 0, Channel B.
BD1: Button Two, Wiegand Data 1, Channel B.
CD0: Button Three, Wiegand Data 0, Channel C.
CD1: Button Three, Wiegand Data 1, Channel C.
DD0: Button Four, Wiegand Data 0, Channel D.
DD1: Button Four, Wiegand Data 1, Channel D.
GND: Power, 0VDC (Ground).
+VDC: Power, 12VDC Nominal.
13.0 Connection
Connection must be done in accordance with NFPA 70. Do not connect to a receptacle controlled by a switch. Connect to a power limited DC
voltage source.
Many Speco Technologies readers carry the following certiļ¬cations:
QUICK START GUIDE
AWRR44 LONG-RANGE
433-MHz RECEIVER
FCC Compliance Statement: This device complies with part 15 of the FCC rules.
Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Caution: Changes or modiļ¬cations not expressly approved could void the user's
authority to operate the equipment.
Product can be used without license conditions or restrictions in all European Union
coun-tries, including Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark,
Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Spain,
Sweden, United Kingdom, as well as other non-EU countries, including Iceland,
Norway, and Switzerland.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference, including
interference that may cause unde-sired operation of the device.
Cet appareil est conforme Ć  Industrie Canada exempts de licence standard RSS (s).
Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne
peut pas provoquer dā€™interfĆ©rences et (2) ce dispositif doit accepter toute
interfƩrence, y compris les interfƩrences qui peuvent causer un mauvais
fonctionnement du dispositif.
Note: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own expense.
800-645-5516 ā€¢ Fax: 631-957-9142 or 631-957-3880 ā€¢ specotech.com
Speco Technologies reserves the right to change speciļ¬cations without notice.


Product specificaties

Merk: Speco Technologies
Categorie: Toegangscontrolesysteem
Model: AWRR44

Heb je hulp nodig?

Als je hulp nodig hebt met Speco Technologies AWRR44 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Toegangscontrolesysteem Speco Technologies

Handleiding Toegangscontrolesysteem