Siemens gigaset 1054i Handleiding

Siemens Vaste Telefonie gigaset 1054i

Lees hieronder de 📖 handleiding in het Nederlandse voor Siemens gigaset 1054i (169 pagina's) in de categorie Vaste Telefonie. Deze handleiding was nuttig voor 50 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/169
Gigaset 1054: A30852-X954-B101-1-76191054TIT.FM28.10.96
s
Operating Instructions
8 mobile units
can be connected
2 non-cordless terminals
can be connected
Cordless Digital DECT Telephone System
Gigaset 1054
Note:
Please read these instructions, with their safety
precautions, before using this equipment!
Gigaset 1054: A30852-X954-B101-1-76191054TIT.FM28.10.96
U5
1054K10.IVZ
Table of Contents
1
Gigaset 1054, GBR.: A30852-X954-B101-1-7619
28.10.96
Important Tips
Safety Precautions ...................................................................................................................... 6
CE Mark of Approval and Certification for the Main Connection and Telephone Systems ......... 6
Putting Into Service
Important Information ................................................................................................................. 7
New Features for Telephone Service .......................................................................................... 7
Step by Step Instructions ............................................................................................................ 8
System Code ............................................................................................................................... 8
Base Station Gigaset 1054
Contents of Package ................................................................................................................... 9
Special Accessories ..................................................................................................................... 9
Tips for the Most Advantageous Installation of the Base Station ............................................. 10
Mounting / Connecting the Base Station .................................................................................. 11
Connection Options at the Base Station ................................................................................... 13
Status of the Base Station Upon Delivery ................................................................................. 13
Mobile Unit
Tips for Individuals with Hearing Aids ....................................................................................... 14
Installing and Charging the Rechargeable Batteries .................................................................. 14
Mounting the Carrying Clip on the Mobile Unit ......................................................................... 15
Important Tips for Using the Rechargeable Batteries ............................................................... 15
Standard Mobile Unit
Displays ..................................................................................................................................... 16
ON OFF, LOCK Status .............................................................................................................. 17
Switching the Status ................................................................................................................. 18
Registering a Standard Mobile Unit at the Base Station ........................................................... 19
Viewing and Setting the Dialing Mode ...................................................................................... 20
Comfort Mobile Unit
Display ....................................................................................................................................... 21
ON, OFF, LOCK Status .............................................................................................................. 22
Switching the Status ................................................................................................................. 23
Registering the Comfort Mobile Unit at a Base Station ............................................................ 24
Viewing Your Own Internal Number ........................................................................................ 25
Viewing and Setting the Dialing Mode ...................................................................................... 26
Non-Cordless Devices
Connection Jacks ...................................................................................................................... 27
Connecting Telephones ............................................................................................................. 27
Connecting Non-Cordless Devices (other than telephones) ...................................................... 27
Examples of Connections for Door Interphones via TFE (entrance telephone) ......................... 28
Introduction
Overview Figures
2
1054K10.IVZ
Table of Contents
Gigaset 1054, GBR.: A30852-X954-B101-1-7619
28.10.96
Operation with Standard Mobile Unit
Standard Settings
Saving / Changing the System Code ......................................................................................... 30
Enter / Change Mobile Unit PIN ................................................................................................ 31
Setting Tone Ring of the Mobile Unit ........................................................................................ 32
Activate / Deactivate Automatic Line Seizure ............................................................................ 33
Activate / Deactivate Automatic Call Pickup .............................................................................. 33
Activate / Deactivate Call Pickup ............................................................................................... 34
Incoming Calls
Accept/Terminate Calls .............................................................................................................. 35
Call Pickup ................................................................................................................................. 36
Answer Call Waiting During an Internal Call .............................................................................. 37
Answer Call Waiting During an External Call ............................................................................. 37
Outgoing Calls
External Dialing, Using Dialpad .................................................................................................. 38
Using the Dialpad for External Dialing as En-Bloc Dialing .......................................................... 39
Number Redial ........................................................................................................................... 40
Number Redial as En-Bloc Dialing ............................................................................................. 40
Internal Call to Another Mobile Unit or Auxiliary Device ............................................................ 41
Internal Dialing with Collective Call ........................................................................................... 41
Dialing Speed Dial Numbers ...................................................................................................... 42
During the Call
Placing a Call on Hold ................................................................................................................ 43
Setting the Handset Volume ...................................................................................................... 44
Mute Feature ............................................................................................................................. 44
Temporary Switch to Tone Dialing ............................................................................................ 45
Speed Dial
Speed Dial Numbers: Storing, Viewing or Changing ................................................................. 46
Delete Speed Dial Numbers ...................................................................................................... 47
Switching Features
Consultation / Transfer Call ........................................................................................................ 48
Internal Consultation ................................................................................................................. 48
External Consultation ................................................................................................................ 49
Toggle ........................................................................................................................................ 50
3-Way Conference ..................................................................................................................... 51
Activate Internal Call Forwarding ............................................................................................... 52
Deactivate Internal Call Forwarding ........................................................................................... 52
Connection with the Door Interphone ....................................................................................... 53
Call Charges, Call Length
Display of Call Length: Activate / Deactivate ............................................................................. 54
Activate / Deactivate Display of Call Charge or Call Charge Unit ............................................... 55
Call Charge Display of Previous Call: Activate / Deactivate ....................................................... 56
Call Charge Factor: Viewing or Setting ...................................................................................... 56
Call Charge Totals per Internal Station: View / Delete ............................................................... 57
Call Charge Totals per Telephone Line: View / Delete ............................................................... 58
1054K10.IVZ
Table of Contents
3
Gigaset 1054, GBR.: A30852-X954-B101-1-7619
28.10.96
Lock
Lock for Outgoing Calls (System Lock): Activate / Deactivate ................................................... 59
Emergency Numbers: Store / View ........................................................................................... 60
Delete Emergency Numbers ..................................................................................................... 60
Barred Numbers: Store .............................................................................................................. 61
Activate / Deactivate Barred Numbers ...................................................................................... 62
Delete Barred Numbers ............................................................................................................. 62
Set Class of Service for the Internal Stations ............................................................................ 63
Locking the Mobile Unit / Activate Hotline ................................................................................ 64
Hotline Number: View / Delete / Store ...................................................................................... 65
Dial Hotline Number .................................................................................................................. 66
Unlock Mobile Unit .................................................................................................................... 66
System Settings
Set the Connection Configuration for Internal Stations ............................................................. 67
Ring Allocation for External Calls ............................................................................................... 68
Ring Allocation: Enter or Change Collective Call Group ............................................................. 69
Ring Allocation: Enter or Change Group Call ............................................................................. 70
Ring Allocation: Enter or Change Number of Ring Cycles for Group Call ...................................71
Ring Allocation for the Door Interphone .................................................................................... 72
Cancel registration Mobile Unit ................................................................................................. 72
Resetting the Base Station to the Status at Initialization ........................................................... 73
Mobile Unit Settings
Advisory and Alarm Tones: Activate / Deactivate .......................................................................74
Resetting the Mobile Unit to Initialization Status ...................................................................... 76
Operation with Comfort Mobile Unit
Using the Menu
Using the Dialog Keys ................................................................................................................77
Using the Menu ..........................................................................................................................77
The Entire Menu .........................................................................................................................77
Menu Structure for System Settings ......................................................................................... 78
Status-Dependent Menus ......................................................................................................... 79
Standard Settings
Enter / Change System Code .................................................................................................... 80
Set Dialog Language ................................................................................................................. 81
Set Tone Ringing for Mobile Unit ............................................................................................... 81
Enter / Change Mobile Unit PIN ................................................................................................ 82
Activate / Deactivate Call Pickup ............................................................................................... 83
Activate / Deactivate Automatic Line Seizure ............................................................................ 84
Mobile Unit Settings .................................................................................................................. 85
Incoming Calls
Accept / Terminate Call .............................................................................................................. 86
Call Pickup ................................................................................................................................. 87
Answer Call Waiting During an Internal Call .............................................................................. 88
Answer a Call Waiting During an External Call .......................................................................... 88
4
1054K10.IVZ
Table of Contents
Gigaset 1054, GBR.: A30852-X954-B101-1-7619
28.10.96
Outgoing Calls
External Dialing with Dialpad ..................................................................................................... 89
External En-Bloc Dialing with Dialpad ........................................................................................ 91
Number Redial ........................................................................................................................... 92
Number Redial as En-Bloc Dialing ............................................................................................. 92
Internal Dialing to Another Mobile Unit or Auxiliary Device ....................................................... 93
Dialing from the Telephone Book .............................................................................................. 94
During the Call
Call on Hold ............................................................................................................................... 95
Temporary Switchover to Tone Dialing ..................................................................................... 96
Change Handset Volume ........................................................................................................... 97
Mute Function ........................................................................................................................... 97
Telephone Book
Entering Names and Characters ................................................................................................ 98
Dialing Convenience with the Telephone Book ......................................................................... 99
Switching Functions
Internal Consultation / Transfer of Call .................................................................................... 101
External Consultation / Transfer Call ....................................................................................... 102
Toggle ...................................................................................................................................... 103
3-Way Conference ................................................................................................................... 104
Activate/ Deactivate Internal Call Forwarding ...........................................................................105
Connection to the Door Interphone ..........................................................................................106
Charges, Call Length
Display of Charges / Display of Call Length ..............................................................................107
Activate and Deactivate Call Length and Call Charge Display / Set the Unit Cost ....................108
Lock
Lock to Prevent Outgoing Calls / Emergency Numbers ........................................................... 110
Enter, View, Delete Restricted Numbers / Activate or Deactivate Lock ................................... 111
Delete All Barred Numbers ....................................................................................................... 112
Set the COS for Internal Stations ............................................................................................. 113
Lock Mobile Unit /Change Hotline Number / Mobile Unit PIN ................................................ 114
Cancel Registration of Mobile Unit Lock (Unlock) ................................................................... 114
System Settings
First Steps for System Settings ................................................................................................ 115
Set Connection Configuration for Internal Stations .................................................................. 116
Resetting the Base Station to the Status at Initialization .......................................................... 117
Ring Allocation for External Calls .............................................................................................. 118
Set / Change Ring Allocation and Ring Cycles .......................................................................... 119
Ring Allocation for the Door Interphone ...................................................................................120
Cancel Registration for Mobile Unit ..........................................................................................121
Mobile Unit Settings
Activate / Deactivate Advisory and Alarm Tones ......................................................................122
Operation with Auxiliary Device
Outgoing Calls
General .....................................................................................................................................123
External Dialing with Digit Dialpad ...........................................................................................123
Internal Dialing to Another Mobile Unit or Auxiliary Device ......................................................123
T Temporary Switchover to one Dialing .....................................................................................124
1054K10.IVZ
Table of Contents
5
Gigaset 1054, GBR.: A30852-X954-B101-1-7619
28.10.96
Incoming Calls
Call Pickup ................................................................................................................................125
Answer Call Waiting ................................................................................................................. 125
Switching Functions
Set Internal Call Forwarding ..................................................................................................... 126
Deactivate Internal Call Forwarding ..........................................................................................126
Placing a Call on Hold ...............................................................................................................126
Consultation / Transferring a Call .............................................................................................. 127
Toggle .......................................................................................................................................128
3-Way Conference ....................................................................................................................128
Connection with the Door Interphone ......................................................................................129
Multicell System
General Information ..................................................................................................................130
Standard Mobile Unit
Registering the Standard Mobile Unit on Multiple Base Stations ............................................131
Base Station Selection, Automatic / Manual / Combined .........................................................132
Activate / Deactivate the Base Station Number .......................................................................133
Comfort Mobile Unit
Register Comfort Mobile Unit on Multiple Base Stations ........................................................134
Base Stations Selection: Automatic / Manual / Combined .......................................................136
Operation on Telephone Systems
Standard Mobile Unit
General Information ..................................................................................................................137
Enter Trunk Code (AKZ) ...........................................................................................................137
Enter Main Trunk Code (HAKZ) ................................................................................................138
Change Length of Timeout after AKZ / HAKZ ..........................................................................139
Deleting AKZ and HAKZ ...........................................................................................................140
Set / Change Time for Flash .....................................................................................................141
Comfort Mobile Unit
General Information ..................................................................................................................142
Enter the Trunk Code (AKZ) .....................................................................................................142
Using the Features
Activating Features of the Telephone System ..........................................................................143
Acoustic Signalling
Signal Tones .............................................................................................................................145
General Information
Taking Care of the System .......................................................................................................146
Technical Data ..........................................................................................................................146
Leaving the Radio Range .........................................................................................................146
Tips for Troubleshooting ........................................................................................................... 147
Warranty ................................................................................................................................... 148
Contact Partners ......................................................................................................................148
Connection Configuration .........................................................................................................149
Glossary .................................................................................................................................. 150
Quick Reference Operating Instructions - Standard Mobile Unit ..................................... 155
Quick Reference Operating Instructions - Comfort Mobile Unit ...................................... 158
Quick Reference Operating Instructions - Auxiliary Device .............................................. 161
6
1054K10.IVZ
Table of Contents
Gigaset 1054, GBR.: A30852-X954-B101-1-7619
28.10.96
3
Gigaset 1054,GBR: A30852-X954-B101-1-76191054K01.FM28.10.96
Introduction
With the purchase of Gigaset 1054, you have selected a cordless system which combines the
advantages of “unrestricted freedom of telephoning” with the convenience of a first rate tele-
communications system.
This device is equipped with modern digital technology based on the latest European standards
for cordless telephones (DECT and GAP). The DECT technology offers, among other things, a
high level of security against unauthorized eavesdropping within the radio cell as well as good
digital voice quality. In addition, it enables the simple expansion of the Gigaset 1054 basic config-
uration -- for example one base station, two mobile units -- to a telephone system which can be
used to place external and internal calls. Mobile units of the Gigaset 1000 series and upward can
be operated on Gigaset 1054.
Gigaset 1054 can be used for both private and professional purposes, for example in office build-
ings and small companies. In addition to the usual telephone functions, it offers, among other
things:
Direct dial to the mobile units or auxiliary devices
2 simultaneous external calls
Operation of 8 mobile units and 2 non-cordless auxiliary devices on one base station
No-charge internal calls among 6 mobile units
Simultaneous use of a maximum of 6 cordless devices
Coding of transmissions between mobile unit and base station
Operation of a mobile unit on up to 4 base stations, thus expanding the radio range within
which you can place and receive calls.
You can install and connect your Gigaset 1054 yourself. To do so, please read the chapter “Put-
ting Into Service.”
The device is pre-set in the factory so that, after putting the base station and mobile unit into ser-
vice, you can begin using the telephone without making any additional settings.
Information about operation of the telephone can be found in the sections:
Operation with Gigaset 1000 S standard mobile unit
Operation with Gigaset 1000 C comfort mobile unit
Operation with non-cordless auxiliary devices.
The other chapters of the operating instructions deal with the special functions and the expan-
sion of Gigaset 1054.
We recommend that you read these additional chapters in order to acquaint yourself fully with
the capabilities of your Gigaset 1054.
At the end of the operating instructions, you will find a capsulated version of the instructions,
including the most important functions. The table of contents and index are provided to help you
find functions, system settings and other information expeditiously.
About this Device
About the Operating Instructions
U2
4
Gigaset 1054, GBR: A30852-X954-B101-1-76191054K01.FM28.10.96
Overview Figures
Front Rear
A Registration Key: B Non-cordless auxiliary device
to register the with the telephone number 0
mobile units
- blinks during registration C Non-cordless auxiliary device
with the telephone number 9
-is lit when plug-in power D Connection jack for
supply is connected telephone line 1
Lamp is identical to the E Connection jack for
the registration key! telephone line 2
F Connection jack for plug-in power
supply C39280-Z4-C65
A
B
C
Front of Gigaset 1054
Rear of Gigaset 1054
B
C
E
DF
U4
5
Gigaset 1054,GBR: A30852-X954-B101-1-76191054K01.FM28.10.96
U3
Overview Figures
Standard Mobile Unit 1000S
Comfort Mobile Unit 1000C
Legend
1 Handset
2 Screen
3 Repeat dial key
4 Memory key
5 Speed dial key
6 Dialpad
7 Internal key
8 Signal key
9 ON/OFF/LOCK key
10 Seize key
11 Microphone
12 Star key
13 Pound key
14 Tone ringing loudspeaker
15 Battery compartment / cover
Front View Rear
Carry clip
11
14
15
Legend
1 Handset
2 Screen (illuminated)
3 Dialog key
4 Dialog key
5 Menu key
6 Dialpad (alpha-
numeric)
7 Internal key
8 Signal key
9 ON/OFF/LOCK key
10 Seize key
11 Microphone
12 Star key
13 Pound key
14 Tone ringing loudspeaker
15 Battery compartment/ cover
Front View Rear
Carry clip
15
14
6
Gigaset 1054, GBR: A30852-X954-B101-1-76191054K01.FM28.10.96
Important Tips
For your safety and protection, do not use the base station or mobile units in bathrooms or
showers (damp areas); the telephones are not waterproof.
Warning
Use only approved rechargeable Nickel Cadmium batteries (NiCd)
(See “Important Information about Using the Battery Cells,” page 15).
Never use other rechargeable battery cells or normal (non-rechargeable) batteries.
These might short circuit or destroy the battery casing (dangerous). Follow the instruc-
tions found on the labels in the battery compartments of mobile units and charging units.
The symbols on these labels state :
Do not immerse batteries in water, and do not expose them to fire.
Do not dispose of old defective batteries in your normal household trash.
Batteries become warm while charging; this is normal and does not represent a danger.
Do not use charging units from other manufacturers, since these could damage the
batteries.Supplemental charging units can be ordered from Siemens.
Use only the AC adapter delivered with your device, bearing the number C 39280-Z4-C65.
Connected non-cordless auxiliary devices (telephone, fax, door interphone...) which have
exposed metal parts might temporarily conduct abnormally high voltage, for instance during
an electrical storm, and should not be touched.
The mobile unit must not be operated in environments where there is danger of explosion.
The Federal Agency for Telecommunication Certification (”Bundesamt für Zulassungen in der
Telekommunikation“) has issued the BZT certification for this telephone system. It has been
approved in line with the EU Guidelines 91/263/EWG, Telecommunication Devices.
This telephone system fulfills the requirements set forth in the EU Guidelines:
89/336/EWG “Electromagnetic Compatibility“
73/23/EWG “Electrical Resources for Use within Certain
Voltage Limitations“
The CE identification mark certifies the device’s conformity with these guidelines.
Safety Precautions
CE Mark of Approval and Certification for the Main Connection and Telephone Systems
– Use only the type listed in the operating instructions
–Use only rechargeable batteries and in the polarity shown.
(See chapter “Inserting and Loading the Batteries“, page 14)
+_
7
Gigaset 1054,GBR: A30852-X954-B101-1-76191054K01.FM28.10.96
Putting Into Service
Dialing Mode
The factory setting on your telephone system is for “tone dialing.” In some cases, it might be
necessary to change the setting to the old dialing mode of “pulse dialing.”
Instructions on how to determine and set the dialing mode are found on page 20 and on page 25.
Connection Cable
The connection cable included with the device is equipped with the TAE connection plug
(TAE = Telephone Adaptor).
If the proper telephone adaptor jack (TAE) is not available at the installation site, it can be ordered
from the German Telekom AG.
Use only original Siemens connection cables. Other cables may have a different configuration.
Power Supply Unit
The power supply unit included with the device is necessary for operation of your telephone sys-
tem.
Telephone Systems
The telephone system is suitable for connection to telephone systems with signal key functions
(consultation) “Flash” and “Ground.”
.
Systems connected to a digital switching exchange of the German Telekom AG have access to a
number of new features such as call waiting, call forwarding, lock and others.
If you want to take advantage of these features, please consult the German Telekom AG. Your
Gigaset 1054 is equipped to accommodate these features.
Important Information
New Features for Telephone Service
8
Gigaset 1054, GBR: A30852-X954-B101-1-76191054K02.FM28.11.96
Putting Into Service
In order to put the Gigaset 1054 telephone system into service, follow the simple step by step
procedure illustrated below :
In order to put your base station into service and to change your settings, you must first enter a
four-digit code, the system code. The procedure for doing this is described in the operating
instructions. At the time of delivery, "0000" is set as the system code. You must use this pre-set
"0000" system code to register the first mobile unit. A separate mobile unit PIN is available for
the disabling of an individual mobile unit.
Recommendation:
We recommend that the system code be changed after registration of the first mobile unit (see
page 30). The system code "blocks" your system from being accessed by any unauthorized indi-
viduals. Registration of additional mobile units as well as system settings can only be carried out
after entering this system code.
Step by Step Instructions
System Code
1 Read the safety precautions! Page 6
2 Assemble charging unit and put into service Instructions for charging unit
3 Prepare mobile units for putting into service Pages 14 - 15
4 Assemble base station and put into service Pages 9 - 13
5 Put the mobile units into service Std. mobile unit P. 16 - 20
Comf. mobile unit P. 21 - 26
Base station and mobile unit are ready for operation, you can place/receive calls
6 Set the ring allocation Standard mobile unit P.69
Comfort mobile unit P.118
You can now use the phone in a target-specific manner.
9
Gigaset 1054, GBR: A30852-X954-B101-1-76191054K02.FM28.11.96
1
3
2 5
4
.Putting Into Service Base Station Gigaset 1054
Base station Operating instructions
TAE connection cables (2) 2 screws and plugs
Plug-in power supply unit
Gigaset 1000S mobile units
Gigaset 1000C comfort mobile units
Rechargeable batteries for mobile units
Gigaset 1000L charging units
Cordless telephone connectors Gigaset 1000TAE
Contents of Package
Special Accessories
1
2
4
5
Operating Instructions
s
Gigaset 1054
Schnurloses digitales DECT-Telefonsystem
8 Mobile units
can be connected
2 non-cordless devices
can be connected
3
4
10
Gigaset 1054, GBR: A30852-X954-B101-1-76191054K02.FM28.11.96
Putting Into Service Base Station Gigaset 1054
If you are using non-cordless telephones along with this cordless telephone, we recommend
that you keep as great a distance as possible between the telephone and the base station in
order to prevent humming (technical source) noises on the telephone.
Place the base station at the most central site possible within the range in which you want to be
able to use the phone. For example:
The base station should, if possible, be installed at an easily accessible site. For example:
If you also want to be able to use the phone outside of the building, install the base station:
Installation Site / Selection of the Mounting Site
In selecting the installation site, the following criteria should be taken into consideration:
1. The telephone connection cable must be long enough to reach the jack of your TAE connec-
tor.
2. A 220/230 V electrical outlet must be available at the installation site for supply of power to
the base station.
3. In order to prevent mutual interference, the installation site should not be in direct proximity
to other devices such as, for example, a HiFi, office equipment or microwave appliances.
The base station is designed for operation in protected rooms with a temperature range of
0 to +50 °C. It should not, for example, be installed in the bathroom, laundry room, damp base-
ment rooms or near heat sources, such as, for example, radiators. It should also not be installed
at a site exposed to direct sunlight.
Tips for the Most Advantageous Installation of the Base Station
in the hallway of your apartment,
in a centrally-located room of your house, office or apartment,
not in the basement,
not in the attic.
in an open space in the room,
not in alcoves,
not behind metal doors, heavy furniture, metal cabinets,
not in places which are especially heavily shielded from radio waves by thick (steel)
concrete walls or metal walls.
as near to window level as possible,
in a room facing your grounds.
11
Gigaset 1054, GBR: A30852-X954-B101-1-76191054K02.FM28.11.96
Putting Into Service Base Station Gigaset 1054
Range
Depending on the surroundings, the outdoor range can be up to about 300 m. Within buildings,
depending on spatial and structural conditions, a range of up to 50 m is possible.
If you should leave the range, you will lose the radio contact to the base station and the
symbol on the screen will blink. If you have activated the range alarm (delivery status = deactiva-
ted), a supplemental warning tone will sound before you leave the radio range.
The device can be installed on a flat surface (for example, on a desk or shelf) or mounted on the
wall.
1. First plug the mini western plug of your telephone cord into the jack labeled "L1" or
"L2" (bottom of base station).
If only one external telephone line is to be connected to Gigaset 1054, the "L1" should be
used.
2. Plug the mini western plug of the cable into the plug-in power supply, using the jack labeled
“ (bottom of base station).
3. Place the cable inside the molded channel.
If you want to mount the device on the wall, follow the steps below after carrying out those
above; if it is not to be wall mounted, proceed to step 8:
4. Drill two holes (Ø 5mm), 69 mm apart.
5. Insert two plugs.
6. Screw the screws into the wall, leaving 2 mm between the head of the screw and the wall.
7. Hang the base station on the wall by lining up the heads of the screws with the holes in the
base station and pushing down briefly on the base station until it is firmly mounted.
8. Insert the TAE plug of the telephone connection cable into the telephone jack.
9. Insert the plug-in power supply into the 220/2230V electrical outlet.
Note:
In the case of loss of power, it is still possible to place a call using a supplemental non-cord-
less telephone connected to the “0” jack.
Use the plug-in power supply delivered with your unit, C 39280-Z4-C65.
Be careful not to mix up the connections for the telephone cable and the plug-in power sup-
ply on the base station. If these are plugged incorrectly, the base station will not function;
damage to the base station could also result.
Mounting / Connecting the Base Station
12
Gigaset 1054, GBR: A30852-X954-B101-1-76191054K02.FM28.11.96
Putting Into Service Base Station Gigaset 1054
120 mm
180 m m
170 mm
5 mm
5 mm
Specifications for Wall Mounting
Connections for Gigaset 1054
Telephone
connection cable Plug-in power supply
13
Gigaset 1054, GBR: A30852-X954-B101-1-76191054K02.FM28.11.96
Putting Into Service Base Station Gigaset 1054
The system is delivered with the following factory settings:
Direct trunk access Fully trunk authorized
Automatic line seizure ON
Call charge recording OFF
Unit charge rate 0.00
Display duration of call ON
Configuration auxiliary device Telephone
Ring allocation Collective call
System code 0000
Dialing mode DTMF
Signal key Flash/250 msec
Connection Options at the Base Station
Status of the Base Station Upon Delivery
#
G OH NI M
P S XYQR W Z
1 3
DEF
2
ABC
9
7
4 6
*
F
0221731550
Su
mm
R
ü
ck
E
en
JKL
5
TUV
8
. -
0
INT #
G OH NI M
P S XYQR W Z
1 3
DEF
2
ABC
9
7
4 6
*
F
0221731550
Su
m
m
R
ü
ck
E
en
JKL
5
TUV
8
. -
0
INT
faxmachine
Rear view of
Gigaset 1054
Mobile units
Plug-in
power supply 230V socket
TAE
connec-
tion cables
Telephone
TAE connection cables
Non-cordless device:
if present
14
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K03.FM
Putting Into Service Mobile Unit
The Standard mobile unit can be used in temperature ranges between 10° C and 55° C, the Com-
fort mobile unit in ranges between 0° C and 45° C . Do not expose to water.
Individuals with hearing aids should be aware that radio signals are projected into the hearing
aid and, if strong enough, can result in a very disturbing humming tone.
The mobile unit receives its power via 2 rechargeable batteries. In order for the mobile unit to
function, these batteries must be installed in the battery compartment and the compartment
cover must be closed.
1. Installing the batteries in the mobile unit
Hold the mobile unit with the dialpad facing down. The compartment for the two recharge-
able batteries is in the lower part of the mobile unit.
Slide the rechargeable batteries (included with your unit) into the compartment, as shown in
the figure below. Be sure that the polarity orientation of the batteries is correct. The plus and
minus signs are labeled in the battery compartment (see figure below).
From the top, slide the battery compartment cover into the slots (see figure) of the mobile
unit and snap into place.
Note:
If the rechargeable batteries are not correctly installed, the mobile unit will not function.
2. Charging the rechargeable batteries
The batteries are not charged at the time of delivery. To charge the batteries, place the mobile
unit in the charging unit (not included). The dialpad can be facing either up or down. However, the
charging contacts on the bottom of the mobile unit must be in contact with those on the bottom
of the charging unit.
If the mobile unit is properly inserted for charging, the LED (light-emitting diode ( B ) will remain
lit, signalling that the battery is charging.
The charging time can vary greatly, depending on the age and the manufacturer/type of recharge-
able battery. The charging logic of the mobile unit always guarantees, however, an optimum
charge of the rechargeable batteries.
Tips for Individuals with Hearing Aids
Installing and Charging the Rechargeable Batteries
15
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K03.FM
Putting Into Service Mobile Unit
The carrying clip can be mounted if desired. Grasp the mobile unit, holding the dialpad in the
palm of your hand. You will see small holes parallel to the screen. Insert the clip first into the hole
on one side and then snap it into the hole on the other side.
The mobile unit comes with two rechargeable AA Nickel Cadmium batteries (Mignon
cells)
Use only the batteries which come with the product.
If replacement is necessary, use only approved batteries of the following types: Panasonic
P-60 AA, Philips R6 NC-P, Saft RC6, UCAR RC6, DAIMON ACCU 1000, Varta 751 RS,
Sanyo N-3UN, Sanyo N-3UC.
The use of other battery types or of non-rechargeable batteries can cause problems with
operation, and may even damage the device.
The manufacturer does not accept any responsibility in such cases.
Do not use normal batteries! Use only approved rechargeable batteries!
When putting into service and using the rechargeable batteries, please observe the fol-
lowing basic principles:
Before use, be sure that the batteries are adequately charged.
We recommend that they be charged without interruption for about 16 hours -- for example
overnight -- and that, during the first week of use, the mobile unit always be replaced in the
charging unit after use.
New rechargeable batteries generally do not attain their full operating capacity (i.e. length of
time that the charge is held for calls and standby status) until they have been in normal use
for several days. Even ifthe charging LED signals that the batteries in the mobile unit are
charged -- LED off -- , it is nevertheless possible that, during the first few days, the normal
call and standby time has not yet been fully reached.
After complete initial charging, the batteries attain their normal operating status. We recom-
mend that, after this initial charging, the mobile unit not be replaced in the charging unit each
time it is used. The rechargeable batteries function best if they are completely discharged
periodically.
Warning: Limited operating time when batteries are partially discharged
Be sure that the battery contacts do not come into contact with metallic or greasy parts.
Replacement battery packs (reserve) can be charged in the charging unit; these should be
exchanged periodically with those in the mobile unit.
3. Rechargeable Battery- Operating and Charging Times
Mobile Unit Gigaset 1000S Gigaset 1000C
Continuous call up to 7 hours up to 5 hours
Standby status up to 50 hours up to 40 hours
Charging times in mobile unit, in the charging unit about 5 hours
Charging times in reserve compartment, in the charging unit about 24 hours
Mounting the Carrying Clip on the Mobile Unit
Important Tips for Using the Rechargeable Batteries
16
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K03.FM
Putting Into Service Standard Mobile Unit
Symbol Explanation
uDisplay after pushing the signal key, e key.
UDisplay of call forwarding, if programmed.
PManual dial pause
zMemory empty.
AAKZ discriminating digit (only significant if behind telephone system)
HHAKZ (only significant if behind telephone system)
nDisplay of the star key, *key.
-Display of the pound key, #key.
Symbols Explanation
AShows that the mobile unit is in save status and is not ready to dial.
Can be activated using the wkey.
BBattery symbol blinks about 5 - 10 minutes before the batteries are empty.
If the mobile unit is in the charging unit and is charging, then this symbol appears.
CON symbol. Can be activated using the u key.
DConnect symbol shows that a radio channel to the base station exists.
Can be activated using the gkey.
EShows that the signalling method has been temporarily switched from
pulse to tone dialing.
FShows that an external connection exists via the base station.
GShows that an internal connection exists via the base station.
HShows that the mobile unit is locked.
Displays
The top lines display all numbers and symbols,
the bottom lines display the symbols for different
operating statuses.
A BC E F HD G
uU
PzAH
n
-88888888
17
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K03.FM
Putting Into Service Standard Mobile Unit
The mobile unit can be set to three different statuses.
• OFF
No calls can be placed and no incoming
calls are signalled.
• ON
Calls can be placed and received.
In order to pick up a call, simply remove the mobile
unit from the charging unit.
or
If the mobile unit was not in the charging unit, then
press the g key.
• LOCK
This protects the dialpad of the mobile unit
against unintentional use, for example when
it is being carried in your pocket. Incoming calls can
be accepted just as in ON status. For the call, the
mobile unit switches automatically to the ON status.
Outgoing calls are not possible.
Note:
If the mobile unit is not within the radio range of the base station, the C symbol blinks on
the screen. It is not possible to place or receive calls.
Procedures can be interrupted by pressing the gkey once or, if necessary, twice.
ON OFF, LOCK Status
C
C
C
18
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K03.FM
Putting Into Service Standard Mobile Unit
Switching from ON status:
uto OFF status:
Push the key until the display on the
screen goes off.
You will hear the key acknowledg-
ment tone.
to LOCK status:
Push key briefly, until the
display is updated.
You will hear the key acknowledg-
ment tone.
Switching from OFF status:
uto ON status:
Push the key until the
display appears on the screen.
You will hear the key acknowledg-
ment tone.
or
Simply place the mobile unit in the
charging unit.
You will hear the key acknowledg-
ment tone.
Switching from LOCK status:
uto ON status:
Push key briefly, until the display
is updated.
You will hear the key acknowledg-
ment tone.
uto OFF status:
Push the key until the display on
the screen goes off.
You will hear the key acknowledg-
ment tone.
Note:
The mobile unit must be in ON status in order to dial or to to use the memory.
Switching the Status
C
C
C
C
C
C
19
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K03.FM
Putting Into Service Standard Mobile Unit
Every additional mobile unit acquired must first be registered at the base station.
For this, follow these steps:
1. The mobile unit must be switched off
If necessary, turn it off by pushing the
u key until the display on the screen goes off.
2. Push the registration key on the base station.
Please use an object with a
sharp point (e.g. pencil, ballpoint pen).
The registration key will blink.
3. Next (within 1 minute) on the mobile unit:
The mobile unit must be switched off.
oPress the 1 and
hold it down.
(This is done to stipulate the base
station number)
u In addition, push the ON key until the
display appears on the screen.
oEnter the system code.
At the time of delivery, the
system code is set as 0000.
#Complete entry of the system code.
Please wait until the connection to the
base station is established.
All of the non-assigned internal station
numbers appear on the screen;
shown here, 1 to 8.
! ( ... Enter the desired internal station num-
ber for the mobile unit, i.e. push one of
the number keys between 1 and 8;
here, for example, 2 is pushed.
The mobile unit is registered.
If the display of the base number is acti-
vated, you will now see the base num-
ber.
Note:
Up to 8 mobile units can be registered on one base station.
If 8 mobile units are already registered, three dashes appear when the system code is
entered during the registration procedure; a negative acknowledgment tone sounds.
To deactivate mobile unit, see page 72.
Registering a Standard Mobile Unit at the Base Station
Registration key
C
1-
C
1---
C
1
A
D
12345678
20
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K03.FM
Putting Into Service Standard Mobile Unit
The German Telekom AG offers two different dialing modes for telephone connections:
Dial pulsing system (Dial Pulsing System = DPS)
Dual-tone (multifrequency system = DTMF)
A the time of initialization, your new telephone is set for tone dialing.
Tone dialing (DTMF) is, however, only possible if your telephone lines are connected to a new
digital switching exchange. The German Telekom AG has, however, not yet completely finished
converting all telephone lines in Germany to digital switching exchanges.
Determining the Dialing Mode of Your Telephone:
Push the connect key and then dial any digit (for example, 2).
If you then still hear the same dial tone, you will have to switch the dialing mode.
w# Push the memory key followed by the # key.
This opens the memory.
1Push the 1 key.
This activates the procedure.
oEnter the system code.
Every digit entered replaces one dash.
1“ Select external telephone line 1 or 2.
zPush the repeat dial key.
DPS
§ Push the keys 0, 3, 3..
Tone Dialing, Signal Key Flash for Telephone Systems (Setting the Flash, see page 141)
/ Push the keys 0, 3, 7.
T Tone Dialing, Signal Key Flash (length/250 ms) for elephone Service on
Main Connection (status upon delivery)
( Push the keys 0, 3 , 8.
wPush the memory key.
The dialing mode is now programmed.
Viewing and Setting the Dialing Mode
A
C
D
-
A
C
D
1 ____
A
C
D
1 _
A
C
D
012
A
C
D
A
C
D
03 3
A
C
D
03 7
A
C
D
03 8
C
21
Gigaset 1054, GBR: A30852-X954-B101-1-76198.11.96 1054K04.FM
Putting Into Service Comfort Mobile Unit
There are four lines on the graphics screen of your Comfort
mobile unit.
During dialing, the number which is being dialed is enlarged and
displayed across two lines.
The bottom lines contain the display fields for the dialog keys.
All displays are shown in clear text.
Some displays are illustrated with graphics; these are explained
in the tables below.
Graphic Explanation
You are being called
Set the ringer volume (6 levels)
Tone ringer off
Set tone ringer pitch (10 levels)
Set tone ringer melody (10 levels)
Set handset volume (3 levels)
Set contrast (6 levels)
Switch signal tone on or off
Locked or unlocked status
If the charge of the rechargeable batteries goes below a
certain level, this symbol appears periodically for 2
seconds.
Display
External 1
0123456
F
CONSLT.
Dialog keys
MUTE
22
Gigaset 1054, GBR: A30852-X954-B101-1-76198.11.96 1054K04.FM
Putting Into Service Comfort Mobile Unit
The mobile unit can be set to three different statuses.
1. OFF
No calls can be placed and no incoming calls are signalled.
2. ON
Calls can be placed and received.
In order to answer a call, simply remove the
mobile unit from the charging unit.
or
If the mobile unit was not in the charging unit,
then press the gkey.
3. LOCK
This protects the dialpad of the mobile unit from unintentional
use, for example, when it is being carried in your pocket.
Incoming calls can be accepted just as in ON status. The mobile
unit switches automatically to ON status for the call.
Outgoing calls are not possible.
Note:
If the mobile unit is not within the radio range of the base
station,, then the text “Srch.station X” blinks on the screen,
whereby X is the stipulated base station number.
A procedure can be interrupted by pushing the gkey
once, or if necessary, twice.
ON, OFF, LOCK Status
Station 1
TEL.BOOK REDIAL
Keyboard
protected
Srch.station 1
TEL.BOOK REDIAL
23
Gigaset 1054, GBR: A30852-X954-B101-1-76198.11.96 1054K04.FM
Putting Into Service Comfort Mobile Unit
Switching from ON Status:
uto OFF status:
Push the key until the display on the
screen goes off..
You will hear the key acknowledgment tone.
uto LOCK status:
Push the key briefly, until the display
is updated.
You will hear the key acknowledgment tone.
Switching from OFF Status:
uto ON status:
Push the key until the
display appears.
You will hear the key acknowledgment tone.
or
Simply place the mobile unit in the
charging unit.
You will hear the key acknowledgment tone.
Switching from LOCK Status:
uto ON status:
Push the key briefly, until the
display is updated.
You will hear the key acknowledgment tone.
uto OFF status:
Push the key until the
display goes off.
You will hear the key acknowledgment tone.
Note:
The mobile unit must be in ON status in order to dial or to use the memory.
Switching the Status
Station 1
TEL.BOOK REDIAL
Keyboard
protected
Srch.station 1
TEL.BOOK REDIAL
Station 1
TEL.BOOK REDIAL
Keyboard
protected
Station 1
TEL.BOOK REDIAL
24
Gigaset 1054, GBR: A30852-X954-B101-1-76198.11.96 1054K04.FM
Putting Into Service Comfort Mobile Unit
Every additional mobile unit acquired must first be registered at the base station.
For this, follow these steps:
1. Push the registration key on the base station.
Please use an object with a sharp point (e.g. pencil, pen).
The registration key begins to blink.
2. Then, on the mobile unit (within 1 minute):
If you switch on a Comfort mobile unit
which is not registered at any base station,
the following display appears.
Push F key,
Push F key,
Main menu appears
Push this key repeatedly until “Settings”
appears on the 1st line of the main menu.
Push this key to select “Settings”
The next menu level appears
Push this key repeatedly until “Register”
appears on the 1st line of the main menu.
Push this to select “Register”
Scroll to select the base station.
The selection of the base station number,
stipulates the station on which your mobile
unit is to be operated; here, station 1.
Registering the Comfort Mobile Unit at a Base Station
Registration key
uRegister !
ßSrch.station
REDIALTEL.BOOK
ßTelephone book
Redial
Telephone lock
OKNEXT
NEXT Settings
Station selection
Service
OKNEXT
OK Handset volume
Tone ringing
Display contrast
OKNEXT
NEXT Register
Language
Autom.backlight
OKNEXT
OK Station 1
Station 2
OK
Station 3
NEXT
NEXT
OK Registration
Srch.station 1
Continued
25
Gigaset 1054, GBR: A30852-X954-B101-1-76198.11.96 1054K04.FM
Putting Into Service Comfort Mobile Unit
Enter the 4-digit system code. (Set at
“0000” upon delivery).
If necessary, correct with .
Push if you want to view but not register it.
or
Confirm that you want to register the Com-
fort mobile unit at the base station with that
number.
Select one of the internal numbers which is
still available (for example, “4”).
The mobile unit can then be reached at this
base station, using this internal number.
Confirm the internal number.
If necessary, correct with .
Close the registration procedure.
The Comfort mobile unit displays the inter-
nal number with which it is registered.
Note:
You can register your Comfort mobile unit on up to four base stations.
Up to 8 mobile units can be registered on one base station.
If 8 mobile units are already registered, the message “No free internal No.” appears on the
screen during the registration procedure after the system code is entered.
To deactivate a mobile unit, see page 121.
Push internal key.
Your station number is displayed;
Here, the 1.
Push this key to return to the idle status.
Viewing Your Own Internal Number
oEnter
system code:
* * - -
OK
NO Register
on
Station 1
OKNO
OK
1 8... Please enter
INT. No.:
1 2 3 4 5 6 7 8
OK Own
4 OK
Internal no.:
OK
Registered
with
Internal no. 4
üOwn:
Coll.call
Internal No.: 1
gStation 1
TEL.BOOK REDIAL
26
Gigaset 1054, GBR: A30852-X954-B101-1-76198.11.96 1054K04.FM
Putting Into Service Comfort Mobile Unit
The German Telekom AG offers two different dialing modes for telephones:
Dial pulsing system (Dial Pulsing System = DPS)
Dual-tone (multifrequency system = DTMF)
At initialization, your telephone is set for tone dialing.
Tone dialing (DTMF) is, however, only possible if your telephone lines are connected to a new
digital switching exchange. The German Telekom AG has, however, not yet completely finished
converting all telephone lines in Germany to digital switching exchanges.
Determining the Dialing Mode of Your Telephone Connection:
Press the connect key and dial any digit (for example, 2).
If you still hear the same dial tone after dialing the digit, you will have to switch the dialing mode.
The dialing mode must be individually set for both external telephone lines:
1. In the idle state, press the ßkey and select “Service” from the main menu.
2. In the service menu, select “System Settings” and enter the system code.
(See also page 115).
After the correct system code is entered,
the following display appears:
Scroll, using NEXT ...
until “Line data” appears in the 1st line;
confirm with OK.
Scroll, using NEXT, to select the external
telephone line for which the call allocation is
to be set,
e.g. External 1; confirm with OK.
Confirm “Dial data” with OK..
Confirm “Dialing mode” with OK.
The menu for setting the dialing mode is
displayed (complete menu at left).
Note:
In order to operate your Gigaset 1054 on a main station connection, you only need the
“DTMF/Flash 0.25” or “DPS/ground” settings.
The additional dialing mode settings are for operation of the
Gigaset 1054 as part of a telephone network (see page 137)ff.
Viewing and Setting the Dialing Mode
OK
Duration/units
NEXT
Call barring
Sys cd/Mn sys cd
Line data
Act.: DTMF/Fl0,25
New: DPS/ground
New: DTMF/ground
External 1/2
Dial data
Dialing mode
New: DTMF/Flash
- - - - - - - -
External 1
External 2
OKNEXT
OK
Dial data
NEXT
Call data
Pause duration
OK
Time for ground
NEXT
Time for flash
Dialing mode
OK
New: DPS/ground
NEXT
New: DTMF/ground
Act.: DTMF/Fl0,25
27
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K05.FM
Putting Into Service Non-Cordless Devices
The Gigaset 1054 base station is equipped with two telephone jacks (B and C), for connecting
non-cordless terminals. Internal station numbers are automatically allocated to the jacks:
Jack B (upper) has the internal station number 0
Jack C (lower) has the internal station number 9
The connections of the auxiliary devices must have TAE plugs. The Gigaset 1054 jacks have the
code F/N.
Only approved non-cordless devices can be connected.
Telephones can be connected immediately, without changing any settings. A telephone or non-
cordless device does not have to be registered at the base station.
The dialing mode (pulse or tone dialing) is recognized automatically and does not need to be set.
It is not possible to set up connections with two non-cordless devices simultaneously.
A signal key on the telephone has no function once the telephone is connected to Gigaset 1054
(exception: telephones with tone dialing).
The telephone does not display any call charges. Call charges are, however, recorded by the
system. The charge sums per station and per multiple subscriber number can be queried or dele-
ted from a registered mobile unit.
The settings necessary for the auxiliary device connection can be programmed using a registered
mobile unit.
You can stipulate whether a fax device, modem, VTX, a door interphone or an answering
machine is to be connected (see page 67 or page 116 ).
In addition, other station-specific settings, e.g. trunk authorization, call allocation, etc., can be
programmed -- using a mobile unit -- for every connected auxiliary device.
When a fax device is used with Gigaset 1054, the fax must be set for operation behind a
telecommunication system (see the operating instructions for your fax machine).
You can use the following Baud transmission rates on the station connections:
Jack B (upper), internal station number 0: up to 28,800 Baud
Jack C (lower), internal station number 9: up to 9,600 Baud.
Connection Jacks
Can be connected Internal station no. Register on system as
T Telephones (Jack B or C) 0 or 9 elephone
Answering machine (Jack B or C) 0 or 9 Telephone
Fax devices (Jack B) 0 Fax or “Neutral“
Modems (Jack B) 0 Modem
T-Online (VTX) devices (Jack B) 0 Modem
External bell (Jack B or C) 0 or 9 Telephone
Door interphone (Jack C) 9 Door interphone
Connecting Telephones
Connecting Non-Cordless Devices (other than telephones)
28
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K05.FM
Putting Into Service Non-Cordless Devices
The following example shows how Gigaset 1054 can be connected to different types of door sta-
tions via door interfaces, using the Siemens door interphone adapter.
Door interphone adapters are available in retail stores.
Connection Points for the TFE Adapter Box
a1/b1 Connection points for the voice wires leading to Gigaset 1054
TO1/TO2 Connection points for the door opener
KL1/KL2 Connection points for the doorbell button
a2/b2 Connection points for the voice wires leading to the door interphone
TS1/TS2 Power-on contacts for the interphone amplifier
UB1/UB2 Connection points for the doorbell transformer
Note:
Ring allocation of the door interphone, see page 72 or page 120.
Connection with the door interphone, see page 53 or page 106.
Examples of Connections for Door Interphones via TFE (entrance telephone)
Conne on ab ecti c l
Gro ht e
TL 290
RITTO
5760 00.
Si led e
TLM 511
Door opener
Doorbell
tran osf rm re
b
a
UB2
UB1
TS1
TS2
9
+
TS
12
11
KL1
KL2
TFE adap et r box
S K A30817- 930- 200
Ampli if erDoo onrs at ti s
o or r
TS
KL1
b1
a1
KL2
TO2
TO1
b2
a2
a
b
Si led e
TLE 051
or
12
+
14
11
12
11
9
+
2
+
6
+
L
U
O
B
9
+
c
b
Si led e
PVG 402
Si led e po e w r supply
NG 402
29
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K05.FM
Putting Into Service Non-Cordless Devices
The following examples show how Gigaset 1054 can be connected to different door station
types with the help of the Siemens door interphone adapter (TFE/V).
Tip:
Any humming
which might occur
can be eliminated
using this
connection.
Please note for door interphone adapter (TFE/V):
The potentiometer should be set on the maximum volume (turn all the way to right).
The X1 bridge must not be changed.
Routing of X2 bridge: SIEDLE TLM 511 RITTO 5760 Grothe TS 6216
In addition, for the individual door stations, a variety of changes must be made:
Door Station Changes in the Door Station
SIEDLE TLM 511 - Open bridges 1, 3, 4.
- Replug loudspeaker wire from “bl” pin to “12“.
RITTO 5760 - Potentiometer on maximum volume
Grothe - Replug yellow wire from “B“ to “0“
Connection Examples for Door Interphones via TFE
TFE V S K A/ 30817- 936- 313
Bridge 1 X
Bridge 2 X
Po en ot ti me et r
L
O
B
U
12
13
14
11
L 1S
L 2S
MIC+
MIC-
Co e o a enn cti n c bl
Gro het
TS 6216 RITTO
5760
Si led e
TL 511M
KLI
B
A
KLI
AC
AC
TOE
TOE
220 V
Doo ber ll
k ye s cwit h
Doo erb ll
tr r ra onsf me
8 12 - V
Si led e
TL 051M
12
+
14
11
2
+
6
+
Gigase 1054t
Doo opene un onr r f cti
no a a ab et v il l
AC
AC
1000uF
20V
40 1V/ A
30
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Standard Settings
For your own protection, you can enter a new system code for the system. This protects your
system settings and prevents registration of additional mobile units without the code. All entries
are carried out from a mobile unit. The system code at the time of initialization is 0 0 0 0.
w#( *
Press these keys in sequence .
oEnter the previously-set system code.
Every digit entered replaces one dash;
thereafter r, 8 dashes appea .
oEnter the new system code
(be sure to note this).
Every digit entered replaces one of the
first 4 dashes.
oEnter the new system code again.
Every digit entered replaces one of the
last 4 dashes.
wPush the enter key to complete
the procedure.
Note:
If you have entered an erroneous system code, a negative acknowledgment tone is sig-
nalled and the display will blink.
A procedure can be terminated by pushing the connect key.
If you forget your system code, it will be necessary to disassemble your device. Forgetting
your system code is like losing a key. If this happens, please contact your system vendor.
Saving / Changing the System Code
A
D
8--- - --
n
A
D
8-- -
n
A
D
8- --- -- --
n
A
C
D
8-- --
n
C
31
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Standard Settings
In addition, you can enter a new individual PIN for each mobile unit. This prevents unauthorized
access, for example, to the personal data which you have stored. In addition, the mobile
unit PIN is necessary for: Locking the mobile unit and enabling hotline, programming the hotline,
unlocking the mobile unit and changing the mobile unit PIN. At initialization, the PIN is 0 0 0 0 .
wPush the enter key.
The memory is opened.
(Push the 8 key.
The procedure is activated.
)Push the 9 key.
Enter the previously-set mobile unit
PIN .
oEvery digit entered replaces one dash;
thereafter r, 8 dashes appea .
Enter new mobile unit PIN
(be sure to note this number).
oEvery digit entered replaces one of the
first 4 dashes.
Enter the new mobile unit PIN again.
oEvery digit entered replaces one of the
last 4 dashes.
wPress the enter key again.
The procedure is complete.
The new mobile unit PIN is stored.
Note:
If you have entered an erroneous mobile unit PIN, a negative acknowledgment tone will be
signalled and the display will blink.
A procedure can be terminated by pushing the enter key.
If you forget the PIN, it will be necessary to disassemble your system.
Forgetting a PIN is like losing a key.
If this should occur r, please contact your telephone vendo .
Enter / Change Mobile Unit PIN
A
C
A
C
8
A
C
8 ____ 9
A
C
8 __ 9
A
C
8 ____ ____ 9
A
C
8 ____ 9
C
32
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Standard Settings
Volume
The tone ring volume of the mobile unit can be set at 6 levels.
Level 1 = quiet, Level 6 = loud (status at initialization).
wPush the enter key.
% Push the 5 key.
The tone ring which is set for the mobile
unit rings and the volume level is
shown; here, 2.
o Push any of the number keys (1 to 6).
New setting; here, 6.
wPush the enter key again.
Pitch
The pitch of the mobile unit can be set at 1 of 6 levels.
Level 1 = slow (status at initialization), Level 6 = rapid.
wPush enter key.
&Push the 6 key.
The pitch set for the mobile unit sounds
and the pitch level is shown; here, 2.
o Push any of the number keys (1 to 6).
New setting; here, 5.
wPush the enter key again.
Setting Tone Ring of the Mobile Unit
A
C
A
C
5 2
A
C
5 6
C
A
C
A
C
6 2
A
C
6 5
C
33
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Standard Settings
If the automatic line seizure is activated (status at initialization), an external telephone line is
immediately seized when the connect key is pressed, and a dial tone is heard. If this feature is
deactivated, you must first dial a zero in order to get an outside line.
w#!o
Press the keys shown in the sequence
shown and then enter system code.
Every digit entered replaces one dash
on the screen.
0 Push 0 for both telephone lines
z Push these keys in sequence.
The display shows a list of the
registered subscribers.
oThe current settings are shown.
Select internal station, i.e. push one
number key between 1 and 8; here, 2..
= or 1To activate, push the 1 key (status at initialization).
To deactivate, push the 0 key.
wPush the enter key to complete the
procedure.
If automatic call pickup is activated, you can receive the call immediately by simply picking the
mobile unit up from the charging unit. If it is not activated, you must first push the connect key.
w§( Push these keys in sequence.
The current setting is shown.
= or 1To activate, push the 1 key (status at initialization)
To deactivate, push the 0 key.
wPush the enter key to complete the
procedure.
Activate / Deactivate Automatic Line Seizure
Activate / Deactivate Automatic Call Pickup
A
C
D
1____
A
C
D
1 __
A
C
D
012
A
C
D
n
3 123
A
C
D
n
3 2 1
C
A
C
38 1
C
34
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Standard Settings
Explanations of how to utilize the call pickup feature are found on page 36.
w#!o
Push the keys shown here in the
sequence shown, and then enter the
system code.
Every digit entered replaces one dash
on the screen.
.
0 Push 0 for both telephone lines.
z*/ Push these keys in sequence.
=or 1To activate, push the 1 key (status at initializa-
tion)
To deactivate, push the 0 key
wPush the enter key to complete
the procedure.
Activate / Deactivate Call Pickup
A
C
D
1____
A
C
D
1 __
A
C
D
012
A
C
D
n
7 0
C
35
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Incoming Calls
An incoming call (external, internal) is signalled via tone ringing as well as on the screen of the
mobile unit.
Screen Display Before Call Pickup:
Incoming external call:
Display blinks.
(here, telephone line 1)
Incoming internal call (here, from
mobile unit 2):
Display blinks.
To Pick Up a Call:
either “pick up”the mobile unit
from the charging unit,
or push the connect key g, if the
mobile unit is not in the charging unit.
Screen Display During the Call:
External (here, telephone line 1)
Internal (here, from mobile unit 2)
To Terminate a Call:
either place the mobile unit back in the charg-
ing unit,
or Push the connect key g , if the
mobile unit is not placed back in the
charging unit.
Display After End of Call:
Accept/Terminate Calls
C F
1
C G
2
C
D
F
1
C
D
G
2
C
36
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Incoming Calls
You can pick up an external call within a call group (see page 69) even if the call is not signalled
on your mobile unit (for example, in the case of call forwarding; see page 52).
For this, call pickup must be activated (see page 34).
gPush connect key.
we Push these keys in sequence, to pick up
the external call
or
If “Automatic line seizure” (see page 33) is activated:
= Push this key to seize a free telephone
line
(Display line code).
Call Pickup
C F
1
D
F
1
C
D
F
37
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Incoming Calls
The call waiting tone signals, during a call, that an external call is waiting. Picking up the external
call during an internal call terminates the internal call.
bYou are engaged in an internal call and
hear the call waiting tone.
we Push these keys in sequence in order to
accept the external call immediately
or
gPush the connect key to terminate the
connected internal call.
When the tone ring sounds, you can
pick up the external call.
The call waiting tone signals, during a call, that an external call is waiting.
bYou are currently engaged in an external
call and hear the call waiting tone.
we Push these keys in sequence to pick up
the external call immediately.
(Already-connected external call is
placed on hold).
You can now toggle between the calls
ü# Push these keys in sequence,
(terminate with e)
or set up a 3-way conference call
we Push these keys in sequence,
(terminate with e)
or return to the original call
ePush this key,
Answer Call Waiting During an Internal Call
Answer Call Waiting During an External Call
CD F G
3
A CD F G
C
D
F
- - -
CD F
123456
A CD F
CD F
123456
C
D
F
C
D
F
38
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Outgoing Calls
After putting Gigaset 1054 and the standard mobile unit into service, you can generally place
calls with any mobile unit which is switched to ON.
gSeize external line
Push connect key
Automatic line seizure
is programmed (status at initializa-
tion)
Line code (LKZ) of the available tele-
phone line is shown.
Automatic line seizure is not pro-
grammed
You will hear the internal dial tone
!Seize line 1
or line 2 specifically
=Seize available external telephone line
o
Enter the number to be dialed.
This is then shown on the screen;
here, for example, 123456.
To Terminate the Call:
gPush the connect key or place the
mobile unit back in the charging unit.
Note:
If the trunk line is already being used by another internal station, “---” will blink on the screen of
your mobile unit and you will hear the internal busy signal.
External Dialing, Using Dialpad
C
D
C
D
F
1
C
D
F
C
D
F
1
C
D
F
2
C
D
F
1
C
D
F
1123456
C
39
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Outgoing Calls
En-bloc dialing makes it possible to view the external number which has been entered -- before it
is dialed.
Automatic Line Seizure Programmed
oEnter the number to be called. Here, for
example, 1 2 3 4 5 6.
gPress the connect key within
30 seconds.
The seize symbol will blink on the
screen. You will then hear the dial tone,
and the number is dialed.
The line code appears as the first digit.
Automatic Line Seizure Not Programmed
oEnter the number to be called,
preceded by the line code
(here, for example, 1)
0, 1 or 2, followed by the telephone
number
gPress the connect key
The seize symbol will blink on the
screen. You will then hear the dial tone,
and dialing begins
To Terminate the Call:
gPush the seize key or return the mobile
unit to the charging unit.
Note:
If you want to change a block of numbers which has already been dialed or if you want to re-
enter it, push g twice.
En-bloc dialing can contain up to 22 digits.
Using the Dialpad for External Dialing as En-Bloc Dialing
C
123456
C
D
123456
C
D
F
0123456
C
1123456
C
D
1123456
C
D
F
1123456
C
40
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Outgoing Calls
Number redial enables the user to redial the number which was last dialed.
gPush the connect key.
You will hear the dial tone.
The telephone line is seized
zPush the number redial key.
The telephone number is shown on the
screen; here, for example, the line code
1 and the telephone number 1 2 3 4 5 6
7 8 ;
the number is then dialed.
To Terminate the Call:
gPush the connect key, or return the
mobile unit to the charging unit.
Note:
The number redial memory can contain up to 22 digits.
When a new number is entered, it replaces the previously-entered number.
After pushing the number redial key, you can manually dial additional suffix digits. These suf-
fix-dialed digits are not stored in the number redial memory.
When using number redial as en-bloc dialing, you can select one of the last three numbers
dialed; this number will then be dialed.
z
Device is in idle state
Push number redial key,
the first telephone number appears.
zPush the number redial key repeatedly.
The last three numbers dialed are
shown, one after the other.
gPush the connect key in order to dial the
selected telephone number.
(Line code; here, for example, 0)
Note:
When a new telephone number is entered (which is not one of the three telephone numbers
which are already in the memory), it replaces the previous number.
Number Redial
Number Redial as En-Bloc Dialing
C
D
C
D
F
1
C
D
F
112345678
C
C
12345678
C
34567890
CC
D
F
034567890
41
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Outgoing Calls
ü Push internal key.
Your station number is displayed; here,
for example, 1.
oEnter the station number to be called,
i.e. push one of the keys 0 to 9; here, for
example, 2.
The station number of the mobile unit being
dialed is shown; here, for example, 2.
You will hear the internal ring tone.
The station answers, after seeing on the
screen which station number is calling.
Carry on the internal call...
To Terminate the Call:
gPush the connect key or return the
mobile unit to the charging unit.
Note:
Internal station numbers 0 to 9 are available on the Gigaset 1054.
To view the internal station number on the base station currently in use, press the internal
key. To terminate, return the mobile unit to the charging unit or press the connect key.
If the mobile unit is already engaged in an internal call when an external call arrives, a so-
called camp on (call waiting) tone (see page 37) is signalled.
In this case: Terminate the internal call by returning the mobile unit to the charging unit or by
pressing the connect key. Pick up the external call after hearing the ring tone (“Call Pickup”,
see page 36).
For more information about collective call, see page 68.
ü Press the internal key.
Your station number is displayed; here,1.
* Push the star key.
All registered internal stations, mobile
units and auxiliary devices are displayed
and rung.
You will hear the internal ring tone.
One of the stations answers;
here, for example, 3
You carry on the internal call...
To Terminate the Call:
gPush the connect key or return the
mobile unit to the charging unit.
Internal Call to Another Mobile Unit or Auxiliary Device
Internal Dialing with Collective Call
D
G
D
G
C
D
G
D
G
D
G
C
42
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Outgoing Calls
You can store 10 frequently-used numbers as speed dial numbers. The programming of speed
dialing numbers is described on page 46.
gPush the connect key.
You will hear the dial tone.
ö Push the speed dial key.
Finding and Dialing Speed Dial Numbers
ö Push the speed dial key repeatedly until
the memory location of the desired tele-
phone number appears (here, for
example, memory location 8).
o Enter the digit shown (here, 8) in order
to dial the phone number.
or
Direct Dial of Speed Dial Numbers
o Enter the desired memory location
(here, 8).
The phone number stored at that
memory location is dialed.
To Terminate the Call:
gPush the connect key or return the
mobile unit to the charging unit.
Note:
Speed dial numbers can also be dialed as en-bloc dialing.
You can also suffix dial additional digits.
Speed dial numbers are not stored in the number redial memory.
Dialing Speed Dial Numbers
C
D
F
1
C
D
F
1
C
D
F
8 123456
C
D
F
1123456
C
D
F
1123456
C
43
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit During the Call
An existing call can be placed on hold, for example in order to consult with someone in the room.
During this time, the person on the other end of an external call hears music.
Placing an Internal Call on Hold
bYou are engaged in an internal call.
ü Push the internal key.
The station number of the internal sta-
tion and INT blink.
ePush the signal key in order to retrieve
the call.
Placing an External Call on Hold
bYou are engaged in an external call.
ü Push the internal key.
EXT blinks on the screen.
ePush the signal key in order to retrieve
the call.
Note:
From within the hold status, you can carry out other switching functions; you can, for example,
.... Carry on a confidential consultation (see page 48),
.... Transfer the call on hold to the consultation partner (see page 48),
.... Toggle between the call on hold and the consultation call
(Toggle, see page 50),
.... Set up a 3-way conference (see page 51) (with the call on hold and the consultation
partner).
Placing a Call on Hold
D
G
3
CD G
3
D
G
3
CD F
123456
CD F G 1
C
D
F
123456
44
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit During a Call
You can set the handset volume on your mobile unit; it has three levels (1=normal to 3=loud) .
This adjustment is possible either during a call or when the unit is in ON status.
bYou are engaged in a call...
w = Press these keys in sequence.
The current setting is shown.
(initialization status)
! §... Push the keys (1...3) (e.g.2)
wPush the enter key again.
The volume setting is changed.
Display after the handset-loud setting:
Level 2
(Display only in idle status)
Level 3
If you do not want your call partner to hear you (for example, if you want to consult with
someone in the room), you can temporarily set the mobile unit on mute during an external call.
bYou are engaged in a call...
Mute Feature Activated:
ü Push internal key.
Your call partner cannot hear you. The
line code is displayed
(for example, 2).
Mute Feature Deactivated:
Consulting in the room ...
ePush the signal key.
Your call partner hears you once again.
bYou continue your call...
Setting the Handset Volume
Mute Feature
C
D
F
12345678
A
C
D
F
0 1
A
C
D
F
0 2
C
D
F
C
C
C
D
F
12345678
2
CD F G
C
D
F
12345678
C
D
F
12345678
45
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit During a Call
If your Gigaset 1054 is connected to a telephone line with tone dailing, then the following is not
relevant for you.
If your Gigaset 1054 is connected to a line with pulse dialing (DPS), you have the option of tem-
porarily switching the dialing mode of your Gigaset 1054 from DPS to DTMF (tone dialing).
By switching the dialing mode from pulse to tone dialing, you can enter information via the dial-
pad during a call, for instance in order to query an answering machine or voice mail, or to take
advantage of German Telekom AG services such as “City Call” or “Scall”, etc.
bYou have set up an external connection.
wPush the enter key.
*Push the star key.
The dialing mode is changed to tone
dialing.
You must dial at least one digit before you can temporarily change the dialing mode.
After you have switched, you can switch back and forth between the dialing modes during the
call, using the signal key e . After completing the call, the telephone reverts automatically to
the original dialing mode.
Digits and symbols which are entered while the phone is switched to the alternative dialing
mode are not stored in the repeat dial memory.
The tone dialing symbol appears only during the temporary change of the dialing mode, and dis-
appears during an internal consultation.
At the initialization, the phone is set for tone dialing.
During the switchover, the call charges / length of call display is suppressed.
T Temporary Switch to one Dialing
C
D
F
123456
A
C
D
F
C
D
E
F
123456
Hinweis:
46
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Speed Dial
You can save 10 frequently-used telephone numbers. The procedure for dialing speed dial num-
bers is described on page 42.
Notebook Feature:
You can also program telephone numbers as speed dial numbers during a call.
wöPush the enter and speed dial keys.
o Push one of the digit keys -- 0 to 9 -- to
select a memory location
for example, 8.
The selected memory location “8” is
displayed at the left; beside this is the
memory contents. If the memory loca-
tion is empty, then z is displayed.
Otherwise, the number stored there is
shown; here, 3 3 3 3 3 3.
Confirm Stored Telephone Number:
wPush the enter key;
the current number stored at memory
location 8 is confirmed.
Store New Telephone Number:
o Enter the new telephone number;
for example, 1 2 3 4 5 6.
wPush the enter key.
Note:
10 speed dial numbers, each with up to 22 characters, can be stored; the characters can be
digit, pound, star and signal keys. In the case of longer telephone numbers, only the first 22
characters are stored.
It is also possible to store numbers even if the unit is not connected to a base station.
Change the telephone numbers by overwriting them.
Notebook feature: A telephone number can be stored as a speed dial number even during a
call.
If “No automatic line seizure” is activated, the first digit must be the line code (0, 1 or 2).
Speed Dial Numbers: Storing, Viewing or Changing
A
C
A
C
8 333333
C
A
C
8 123456
C
47
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Speed Dialing
wPush the enter key.
( “ Push the 8 and 2 keys.
o Enter the mobile unit PIN
(see “Enter Mobile Unit PIN”).
Every digit entered replaces one dash
on the screen.
wPush the enter key again.
All speed dial numbers are deleted.
Delete Speed Dial Numbers
A
C
A
C
8- --- 2
A
C
8-- 2
C
48
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Switching Features
With your Gigaset 1054 system, you have the option of carrying on external as well as internal
consultation calls if the second telephone line is free. This feature could be used, for example, to
consult an external business partner.
bYou are engaged in an external call.
ü Push the internal key.
The line code
is shown; here, 1.
=...) Enter the station number desired; here,
2.
or Ring All Internal Stations:
* Push the star key.
You will hear the internal ring tone, an
internal station answers; here, station 2.
You carry on the call with the internal
station.
Call Transfer:
gPush the connect key or replace the
mobile unit in the charging unit.
Or Terminate Internal Consultation and Return to the External Call:
ePush the signal key.
You are reconnected to the external sta-
tion. You continue with the external call.
Note:
After dialing the internal telephone number, you can immediately transfer the external call to
that number by “hanging up.” This can be done even before the internal station answers.
If the station to which you are transferring the call does not answer within 30 seconds, an
automatic recall occurs.
Consultation / Transfer Call
Internal Consultation
C
D
F
12345678
CD F G 1
CD F G
2 1
CD F G
0123
CD F G
2 1
C
C
D
F
12345678
49
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Switching Features
You have the option, with this system, of transferring an external call to another external number
as long as the second telephone line is available.
bYou are engaged in an external call.
If no automatic line seizure is activated:
=dial 0 as the line code
ü # Push the internal key and the pound key
oEnter the external phone number to be
called.
You will hear the ring tone, and the sta-
tion answers. You carry on a consulta-
tion call with the external station.
You can also carry out this procedure from within an internal call.
Or Terminate External Consultation:
ePush the signal key.
The external station which is on hold is
reconnected to you. You continue with
the original external call.
External Consultation
C
D
F
112345678
CD F
2
CD F
234567890
CD F
234567890
C
D
F
12345678
50
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Switching Features
During a consultation call, you can toggle back and forth between two existing calls as often as
you like. External toggle is also possible, if the second telephone line is available.
Toggle Between an Internal and External Station:
bYou are engaged in an external call.
üPush the internal key.
The line code is displayed;
here, 1.
=...),*Enter the station to be called; here, the
3.
Station 3 answers. You carry on the
internal consultation call.
ü # Push these keys in sequence to switch to
the external call.
To return to the internal call, repeat the
key combination.
Terminate the Internal Consultation Call:
ePush the signal key.
Toggle Between Two External Stations:
bYou are engaged in an external call.
If no automatic line seizure is activated:
=dial the 0 as line code
ü # Push these keys to set up an external
consultation call.
oEnter the desired external telephone
number. Carry on the external consulta-
tion call.
ü # Push these keys in the sequence shown
here to switch back to the 1st external
call,
ü # Push these keys in the sequence shown
here to switch back to the 2nd external
call.
Terminate External Consultation Call:
ePush the signal key to disconnect the
2nd external partner.
This procedure can also be carried out from within an internal call.
Toggle
C
D
F
1123456
CD F G 1
CD F G
3 1
CD F G
1123456
C
D
F
1123456
C
D
F
1123456
CD F
2
CD F
2345678
CD F
1123456
CD F
2345678
C
D
F
1123456
51
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Switching Features
During a consultation call, you can connect the two partners, thus setting up a 3-way conference.
An external 3-way conference is possible, as long as the 2nd telephone line is available.
3-Way Conference from Within an Internal Consultation Call:
b You are engaged in an external call.
ü Push the internal key.
Place external call on hold.
=...) ,*Enter the desired station number; here,
3.
Station 3 answers. You are engaged in
an internal consultation call.
wePush these keys in sequence in order to
set up a 3-way conference.
Terminate 3-Way Conference:
ePush the signal key to terminate the 3-
way conference.
(the internal station is disconnected).
3-Way Conference from Within an External Consultation Call:
b You are engaged in an external call.
ü # Push these keys to set up an external
consultation call.
=...) Enter the external number to be dialed.
The external consultation call is set up.
we Push these keys, in sequence, in order
to set up a 3-way conference call.
Terminate the 3-Way Conference:
ePush the signal key to terminate the 3-
way conference (the 2nd external part-
ner is disconnected).
This procedure can also be carried out from within an internal call.
3-Way Conference
C
D
F
123456
CD F G 1
CD F G
3 1
C
D
F
G
3 1
C
D
F
123456
C
D
F
123456
CD F
2
CD F
2345678
CD F 21
C
D
F
123456
52
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Switching Features
You can forward an external call to another internal station. The call can only be forwarded to a
station which also has call forwarding activated.
w#) !
Push these keys in sequence.
=...) Use the digit keys to enter the station
number of the internal station to which
the call is to be forwarded.
=...) Use the digit keys to enter the number
of rings after which the call is to be for-
warded.
w Press the enter key.
Note:
An activated call forwarding is indicated by a “U” on the screen.
(Query by pushing ü).
w#) !
Push these keys in sequence.
w Press the enter key.
Note:
The call forwarding display “U” (query by pushing ü) remains if additional call forwarding
functions are still active.
Activate Internal Call Forwarding
Deactivate Internal Call Forwarding
A
C
D
91
A
C
D
91 7
A
C
D
91 7 3
C
A
C
D
91
C
53
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Switching Features.
The door interphone can only be connected to auxiliary devices which have the internal station
number 9.
Call from door interphone is signalled
(3 short tones).
gPush the connect key. This connects
you with the door interphone.
ü ) Push these keys in sequence to activate
the door opener. The door opener is
activated for 3 seconds. You can acti-
vate the door opener repeatedly.
The connection with door interphone
remains set up.
gPush the connect key in order to termi-
nate the connection to the door inter-
phone.
Connection with the Door Interphone
C G
9
D
G
9
D
G
9
C
D
G
9
54
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Call Charges, Call Length
The automatic call length display is activated after the last digit is dialed. The display remains
visible for 4 seconds after the end of the call.
w#!o
Push these keys in sequence and then
enter the system code .
Every digit entered replaces one dash
on the screen.
! Select either external telephone line 1
or 2.
z)&
Push these keys in sequence.
After digits are entered, the current
setting is shown.
1 or 0 To activate, push the 1 key (initialization status).
To deactivate, push the 0 key.
w Push the enter key.
The call length display is
activated or deactivated.
Call Length Shown on the Screen:
Note:
The call length display can show a maximum of 99 minutes and 59 seconds.
If the call is longer than this, the display counter starts again at 00-00.
Display of Call Length: Activate / Deactivate
A
D
1____
A
C
D
1 __
A
C
D
0 12
A
C
D
96 1
C
Min. Sec.
C
D
F
00-00
55
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Call Charges, Call Length
Before you can use this feature, you must first request from the German Telekom AG the
transmission of the call charge data, if this service has not already been requested for
your phone. However, please note that, for technical reasons, the charges on your telephone bill
may differ from those shown on the screen. The Telekom unit counter is always the official indi-
cator. The following are recorded:
Call charges or call charge units for an individual call from the mobile unit,
Total call charges or call charge units for the mobile unit,
Total call charges or call charge units per telephone line,
Total call charges or call charge units for the entire system.
Note: If the call charge / call charge units display is activated/deactivated, the call length display
is deactivated.
w#!o
Push these keys in this sequence and
then enter the system code.
Every digit enters replaces one dash on
the screen.
!Select external telephone line 1 or 2
.
z)&
Push these keys in sequence.
.
After digits are entered, the current
setting is shown.
or =To activate, push the 2 key
To deactivate, push the 0.
w Push the enter key
.
Examples
Call Charge Display:
Total of 23.46, with individual call charge
of 2.07 for the mobile unit, if call charge
factor is set.
Call Charge Unit Display
Total of 598, with 46 individual call
charge units for the mobile unit, if call
charge factor is 0.00.
Activate / Deactivate Display of Call Charge or Call Charge Unit
A
D
1____
A
C
D
1 __
A
C
D
012
A
C
D
96 1
C
C
D
F
2346 207
. .
C
D
F
000598 0046
56
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Call Charges, Call Length
If this feature is activated (the call charge display must also be activated), the charges for the pre-
vious call are shown after the line is seized. This is ideal, for instance, for hotels or inns which
wish to see the call charges for a guest. For resetting options for the charges, see “Delete Call
Charge Total” on page 57.
w#!o
Push these keys in sequence and then
enter the system code.
Every digit entered replaces one dash
on the screen.
00 for both telephone lines
z*0 Push these keys in the sequence shown
.
1or =Push the 1 to activate.
Push 0 to deactivate.(initialization status)
wPush enter.
If the units / charge display is activated, the mobile unit automatically shows the units. If you
want to see the charge, you must enter the charge factor. The charge factor is valid for all ter-
minal devices connected to Gigaset 1054.
w#("o
Press these keys in the sequence
shown here. Then enter the system
code. Every entry replaces one of the
dashes.
The current setting is shown;
here, 0.00
oEnter the call charge factor (for example,
.12).
Pushing the star key allows the decimal
point to be displayed or not displayed.
wPush the enter key.
Note:
If the call charge factor is entered or changed, all previous individual / total entries are deleted. In
order to view the charge factor, follow the procedure, deleting the step “Enter call charge fac-
tor.”To display the units again, enter “0.00” as charge factor. The charge factor can be program-
med up to 9.99 or 999, and is valid for all stations.
Call Charge Display of Previous Call: Activate / Deactivate
Call Charge Factor: Viewing or Setting
A
D
1____
A
C
D
1 __
A
C
D
012
A
C
D
n
0 0
C
A
C
D
8 ____2
A
D
0. 00
A
C
D
0. 12
C
57
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Call Charges, Call Length
w#(§o
Push these keys in the sequence
shown. Then enter the system code.
Every entry replaces one dash.
The registered internal stations are dis-
played.
View Total Charges
0 )... Enter the internal number.
The total charges for this station are dis-
played.
.üPush this key in order to view total
charges for another station.
0 )... Enter the next internal number for which
you want to view the call charges.
wPush the enter key again.
or
Delete Charge Total
0 )... Enter the internal number
desired.
The total charge for this station is
shown.
0Push this key in order to delete the total
charges for the selected station.
üPush this key in order to view other total
charges, or
wPush the enter key again.
Note:
At the right side of the screen you will see the charges incurred for the current call; at the
left, the total charges incurred for this station up until this point.
Call Charge Totals per Internal Station: View / Delete
A
C
D
8 ____ 3
A
C
D
n
12 456
A
C
D
33.00 2.00
A
C
D
5. 60 1.00
C
A
C
D
5.60 1.00
A
C
D
0..00 0.00
C
58
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Call Charges, Call Length
w#o
Press these keys in the sequence
shown, and then enter the system
code. Every entry replaces one of the
dashes.
The registered internal
stations are displayed.
View the Total Charges
*0!“
Select external telephone line 1 or 2;
Press 0 to select both.
üPush this key in order to view the total
charges for other numbers
or
wPush the enter key to complete
the procedure.
Delete Charge Total
*0!“
Select telephone line 1, 2; or push 0 to
select both. This selects the individual
telephone line or the total system
charge.
0Push this key to delete the total charges
for the selected line or for the system.
üPush this key to view total charges for
another internal number
or
.wPush enter key.
Note:
At the right of the screen, you will see the charges for the current call; at the left, the total
charges incurred up until this point per telephone line.
Call Charge T Totals per elephone Line: View / Delete
A
C
D
8____3
A
C
D
n12 456
A
C
D
012
A
C
D
5. 90 3. 00
C
D
A
C
D
5. 90 3. 00
A
C
D
0.. 00 0. 00
C
59
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Lock
Using the system lock, you can lock your base station. This ensures that no outgoing calls can be
made.
Exception: Calls to an emergency number are possible if these numbers are stored. Up to four
16-digit numbers can be stored (page 60).
Incoming calls can still be accepted when the system is locked.
w#“$o
Press these keys in the sequence
shown
and enter the system code.
Every digit entered replaces one dash
on the screen.
The current setting is displayed.
1 or =To activate, push the 1 key.
To deactivate, push the 0 key (initialization status).
wPush the enter key.
The system lock is activated or deactiva-
ted.
Note:
If you have programmed system lock with emergency numbers as well as telephone lock
with hotline, no dialing is possible.
Exception: When the emergency number is the same as the hotline number.
Lock for Outgoing Calls (System Lock): Activate / Deactivate
A
C
D
2 ____4
A
C
D
2 __4
A
C
D
1
C
60
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Lock
In an emergency, it is important to be able to dial emergency numbers even if the system is
locked. You can program four 16-digit numbers for this.
w#“%o
Push these keys in the sequence shown
and enter the system code.
Every digit entered replaces one dash
on the screen.
z To scroll through the emergency num-
bers, push the repeat dial key repeat-
edly.
Here slot 2 is empty.
0 )... Enter the emergency number for slot
number 2.
Already-existing emergency numbers
can be changed by overwriting them.
z To scroll further, press the repeat dial
key. All emergency numbers can be
entered in one step.
w Push the enter key.
w#“/o
Push these keys in the sequence shown
and enter the system code.
Every digit entered replaces one dash
on the screen.
w Push the enter key.
All emergency numbers are deleted.
Emergency Numbers: Store / View
Delete Emergency Numbers
A
C
D
2____5
A
C
D
2 __5
A
C
D
1 110
A
C
D
2 z
A
C
D
2 211
A
C
D
3 z
C
A
C
D
2____7
A
C
D
2 __7
C
61
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Lock
The storage of barred numbers enables you to prevent numbers from being dialed which begin
with a barred number. Thus, for example, if the barred number “00” is stipulated, international
calls cannot be made. For each mobile unit and for each telephone, you can store up to three
barred numbers (1 to 8 digits in each case). To activate the barred numbers, see “Activating /
Deactivating Barred Numbers” on page 62.
w#(%o
Push these keys in the sequence shown
and enter the system code.
Every digit entered replaces one dash
on the screen.
The registered stations are then dis-
played.
=...) Pus these keys to select a station ;
the first, here empty, barred number
slot is displayed.
Viewing
z Push the repeat dial key
.Additional barred number slots are dis-
played;
z Push the repeat dial key again.
The third barred number is displayed,
etc.
or Enter Barred Number
z Push the repeat dial key.
oEnter the barred number, e.g. 00;
if desired, enter 2nd and 3rd barred
number
üPush to select other internal stations
or
wPush the enter key.
Note:
Changes can be made by overwriting.
Barred Numbers: Store
A
C
D
A
C
D
A
C
D
A
C
D
A
C
D
A
C
D
A
C
D
C
62
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Lock
More information about the barred numbers is found on page 61.
w#($o
Push the keys in the sequence shown
here and then enter the system code .
Every digit entered replaces one dash
on the screen.
A list of the registered stations is dis-
played.
=...) Push these keys to select stations. The
current settings are displayed.
1 or = Push the 1 key to activate,
and the 0 key to deactivate (initialization status) .
wPush the enter key.
Note:
When a barred telephone number is entered, you will first hear the negative acknowledgment
tone and then the busy tone.
For more information on barred numbers, see page 61.
w#(/o
Press the keys in the sequence shown
here and then enter the system code.
Every digit entered replaces one dash
on the screen.
A list appears of the stations which have
a barred number programmed.
=...) Push these to select stations; here, the
3 has been selected.
w Push the enter key.
The barred numbers for station 3 are
thereby deleted.
Activate / Deactivate Barred Numbers
Delete Barred Numbers
A
C
D
8 ____4
A
C
D
8 __4
A
C
D
01234
A
C
D
0
C
A
C
D
8 ____7
A
C
D
8 __7
A
C
D
1 34
A
C
D
1 4
C
63
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Lock
By setting the COS for every registered mobile unit and telephone, you can stipulate which sta-
tions are allowed to place toll calls.
At initialization, all devices have full trunk authorization.
1. Full trunk authorization (= initialization status)
The device is capable of making outgoing and receiving incoming external calls.
2. Incoming authorization
The device is capable only of receiving incoming calls. All external dialing is blocked.
3. Internal authorization
The device can only make internal calls. All external dialing is blocked. Users can set up a
consultation call with an authorized internal station, but cannot transfer an external call; the
call is returned in this case.
w#!o
Press the keys shown in the sequence
shown; enter the system code.
Every digit entered replaces a dash on
the screen.
!Select external telephone line 1 or 2
.
z*!Press the keys shown in the sequence
shown
A list of the registered stations is
shown.
oEnter the internal number of the mobile
unit or auxiliary device to be set, i.e.
push one key between 0 and 9; here,
the 2.
The current setting is shown.
1To activate full trunk authorization Push the 1 (initializ. status)
or
0For incoming authorization Push the 0
or
For internal authorization Push the 2 .
w Push enter key to end the procedure
If your Gigaset 1054 is only being operated on one external telephone line (L1), all authoriza-
tions for the second line (L2) should be programmed for “internal.”
Set Class of Service for the Internal Stations
A
D
1____
A
C
D
1 __
A
C
D
012
A
C
D
n
1 0123
A
C
D
n
1 12
C
Hinweis:
64
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Lock
You can lock your mobile unit, thus preventing unauthorized or unintentional use.
If you have programmed a hotline number, then only this hotline number can be dialed.
If no hotline number is programmed, only incoming calls are possible.
To unlock the mobile unit, see page 66.
w Press the enter key.
(Press the 8 key.
!Press the 1 key
.
o Enter the mobile unit PIN.
Every digit entered
replaces one dash on the screen.
w Push the enter key again.
The mobile unit is locked.
Example:
Display without hotline number.
Display with hotline number.
Note:
After locking the mobile unit, the enter key can only be used to
unlock it (within 3 seconds) or to dial the hotline number.
If you want to lock the mobile unit, without programming a hotline number, any hotline num-
ber which was already programmed into the unit must first be deleted. See “View /Delete /
Enter Hotline Number,”page 65.
We recommend that you check to make sure that the number is correctly entered by making
a test call.
Locking the Mobile Unit / Activate Hotline
A
C
A
C
8
A
C
8____1
A
C
8 __1
C
H
C
H
0123
65
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Lock
You can lock your telephone to prevent outgoing calls while still allowing one hotline number to
be dialed. In this case, only this stored hotline number can be dialed. This can, for instance, be
the number under which you can be reached during your vacation.
wPush the enter key.
( Push the 8 key.
(Push the 8 key.
o Enter the mobile unit PIN.
Every digit entered
replaces one dash on the screen.
View
After the last digit is entered, the hotline
number which has been programmed
is displayed; here, for example, 0123.
or delete
z Press the number redial key.
or enter
z Press the number redial key.
oEnter the desired telephone number.
It is shown on the screen;
here, 1 2 3 4 5 6 7 8 .
w Push the enter key.
Note:
A hotline number can have up to 22 characters, consisting of digits,
pound, star and signal keys.
A hotline number r, programmed via “Enter barred numbe ,” is not dialed.
If automatic line seizure is not activated, the 1st digit must be the line code (0,1 or 2).
Hotline Number: View / Delete / Store
A
C
A
C
8
A
C
8____8
A
C
8 __8
A
C
0123
A
C
A
C
A
C
12345678
66
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Lock
Mobile unit is locked.
oPush any key.
The hotline number is dialed.
gTo terminate the call:
Push the connect key.
Mobile unit remains locked.
Mobile unit is locked.
wPush the enter key.
The memory is opened.
Display without hotline number
or
with hotline number.
(Push the 8 key within 3 seconds.
0Push the 0 key.
oEnter the mobile unit PIN.
Every digit entered replaces one
dash.
wPush the enter key.
The mobile unit is unlocked.
Note:
After pushing the enter key, the 8 key must be pushed within 3 seconds (otherwise, the hot-
line number will be dialed)
Dial Hotline Number
Unlock Mobile Unit
C
H
C
D
F
H
C
H
A
C
H
A
C
A
C
A
C
C
67
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit System Settings
You can stipulate which types of devices can be connected at each station.
Cordless devices (1 to 8) can be mobile units, or devices such as Gigaset 1000TAE which can, for
example, be used to connect telephones and fax machines to Gigaset 1054 without cords. For
these stations, “mobile unit” is pre-set.
For non-cordless connections (0 and 9), the device type “telephone” is pre-set. Modems or fax
machines should preferably be connected to the 0 station, a door interphone can only be connec-
ted to station 9.
w#!o
Press the keys shown in the sequence
shown here and then enter the system
code.
Every digit entered replaces one dash
on the screen.
=Push this key for both telephone lines
z#= Push these keys in this sequence.
Internal station 0 with the “telephone”
setting is displayed
Selecting the Internal Station
zTo select the internal station, push the
repeat dial key multiple times.
The registered stations appear with
their current settings
Example: Mobile unit is set for Internal
1, modemi is set for Internal 0.
Setting for the Equipment to be Connected
Different Types of Equipment:
Digit Key Equipment Type
0 No function
1 Mobile unit
2 Telephone
3 Modem
4 Fax device
5 Door interphone
6 Neutral
(Telephone and Fax)
= ... & Push the digit key to select the type of
equipment; here, non-cordless connec-
tion Internal 0 with fax
wPush enter key.
Set the Connection Configuration for Internal Stations
A
C
D
1____
A
C
D
1 __
A
C
D
0 2
1 1
A
C
D
A
C
D
03
A
C
D
04
C
68
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit System Settings
With the ring allocation for external telephone lines, you can stipulate which mobile unit or auxi-
liary devices should be rung when an external call arrives. The ring allocation is carried out by
entering the internal number in the list of the collective call group or in the group list of the ring
allocation.
Stations which are to receive external calls must, as a minimum, have the COS “incoming call
authorization” (see the chapter „Set Class of Service for the Internal Stations“ on page 63).
Up to 10 stations, of which 8 can be mobile units, can be placed in the lists for collective call or
call diversion.
For stations which are already engaged in an external or internal call, call waiting is signalled.
Collective Call
At initialization, collective call is set for all stations.
An incoming external call is signalled on all registered mobile units and auxiliary devices and
can be picked up by any mobile unit or auxiliary device.
Through programming, an individual call can be routed to only one station in the collective
call list.
Groups of stations which are part of the collective call group
At the time of registration, the stations are automatically placed in the collective call list. This
can be changed subsequently.
Example:
External telephone line Allocated internal stations
1 1
2 2, 3, 4
Group Call with Call Diversion Pickup
An incoming external call for telephone line L1 is first signalled 3x at mobile units 2, 3 and
can be picked up there. If mobile units 2 and 3 cannot accept the call, the call is diverted to
the second call group (with mobile units 6, 7) .
Example:
External Allocated internal stations Ring (after
telephone line Group 1 Group 2 call diversion) at
1 2, 3, 6, 7 6, 7 2, 3, 6, 7
Ring Allocation for External Calls
69
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit System Settings
For more information about this, see page 68.
If more than 6 cordless stations are in operation at once, the telephone number will only be dis-
played at the first five devices which are rung. The last registered stations are affected by this.
w#!o
Push the keys shown in the sequence
shown here and then enter the system
code.
Every digit entered replaces one
dash on the screen.
!" Select external telephone line 1 or 2,
z*" Push these keys in this sequence
!Push key 1 for the collective call group
0 ) ... Push the digit keys of the internal num-
bers desired in order to place them in
the list of stations.
Stations with this internal number are
allocated to the telephone line selected.
wPush the enter key to complete
the procedure.
Example:
External telephone line Allocated internal stations
1 2, 3, 5
If, for example, an external call arrives for line 1, stations 2, 3, 5 are rung simultaneously.
Ring Allocation: Enter or Change Collective Call Group
A
C
D
1____
A
C
D
012
A
C
D
n2
A
C
D
n
2 1 0123
A
C
D
n
2 1 0123 6
C
70
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit System Settings
For more information about this, see page 68.
If more than 6 cordless stations are in operation at once, the telephone number will only be dis-
played at the first five devices when they are rung. The last registered stations are affected by
this.
w#!o
Push the keys shown in the sequence
shown here and then enter the system
code.
Every digit entered replaces one dash
on the screen.
!" Select external telephone line 1 or 2,
z*" Press these keys in this sequence .
" Push 2 for call diversion pickup
0 ) ... Push the digit keys of the desired inter-
nal numbers.
This selects the stations for the call
group 1.
# Push the pound key for the 2nd call
group.
0 ) ... Push the digit keys of the desired inter-
nal numbers. This selects the stations
for the call group 2.
wPress the enter key to complete
the procedure.
Example:
External telephone line Call group 1 Call group 2
1 2, 3, 5 1, 7
If, for example, an external call arrives for line 1, the stations with the internal numbers 2, 3, 5 are
rung simultaneously; afterward, the stations with the internal numbers
2, 3, 5, 1, 7 are rung.
Ring Allocation: Enter or Change Group Call
A
C
D
1____
A
C
D
012
A
C
D
n2
A
C
D
n2 2
A
C
D
n
2 2 012
A
C
D
n
2 2 012-
A
C
D
n
2 2 012- 34
C
71
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit System Settings
For more information about this, see page 68.
You can set the number of ring cycles after which group 1 should answer. If there is no answer
after this number of rings, call group 2 is automatically rung. The factory setting at initialization is
3 ring cycles. You can choose anywhere from 1 to 9 tone rings.
w#!o
Push the keys shown in the sequence
shown here and then enter the system
code.
Every digit entered replaces one dash
on the screen.
!" Select either external telephone line 1
or 2.
z*& Push these keys in this sequence.
! ) ... Push the key for the desired number of
ring cycles. Here, 2
wPush the enter key.
Example:
External telephone line Call group 1 Call group 2
1 2, 3, 5 1, 7
If an external call arrives for telephone line 1, the stations with the internal numbers 2, 3, 5 are
first rung simultaneously 2 x. After that, the stations with the internal numbers 2, 3, 5, 1, 7 are
rung.
Ring Allocation: Enter or Change Number of Ring Cycles for Group Call
A
C
D
1____
A
C
D
1 __
A
C
D
012
A
C
D
n6
A
C
D
n
6 2
C
72
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit System Settings
If you want to set up a door interphone, you can stipulate which internal stations should be rung
from the door interphone. These internal stations can then activate the door opener.
w#!o
Push the keys shown here in the
sequence shown and then enter the
system code.
Every digit entered replaces one dash
on the screen.
0 Select 0 for both telephone lines.
z#& Push these keys in this sequence.
0 ) ... Push these keys to enter the internal
numbers for the station call list
w Push the enter key in order
to complete the procedure.
Every mobile unit can be unregistered using that unit or any other mobile unit.
w#/"o
Push the keys shown in the sequence
shown here and then enter the system
code.
Every digit entered replaces one dash
on the screen.
All registered internal stations appear on
the screen; here 1 to 8.
oEnter the station number of the mobile
unit to be unregistered, i.e. push one of
the digit keys, here, for example, 2 and
5.
When the 5 is pressed again, the digit
reappears, i.e. mobile unit 5 has not
been unregistered.
wPush the enter key, in
order to complete the procedure.
Mobile unit 2 is unregistered.
Note:
To register a mobile unit, see page 19.
Ring Allocation for the Door Interphone
Cancel registration Mobile Unit
A
C
D
1____
A
C
D
1 __
A
C
D
012
A
C
D
-6 0
A
C
D
-6 123
C
A
C
D
7____2
A
C
D
7 __2
A
C
D
12345678
A
C
D
1 34 678
A
C
D
1 345678
C
73
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit System Settings
You can reset the base station to its initialization status, for example if you feel that you no longer
have a clear overview of the current settings. In order to keep this as simple as possible, how-
ever, not all settings are reset.
This procedure accomplishes the following:
a) Resets to initialization b) Deletes: c) Does not change:
status
Settings Units/Charges System code
Configuration Emergency numbers Registration of mobile units
Barred numbers Ring allocation
w#!o
Push the keys shown in the sequence
shown and then enter the system
code.
Every digit entered replaces one dash
on the screen.
0 Select 0 for both telephone lines.
z"%0
Push these keys in this sequence
to reset to initialization status.
wPush the enter key.
Resetting the Base Station to the Status at Initialization
A
D
1____
A
C
D
1 __
A
C
D
012
A
C
D
25 0
C
74
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Mobile Unit Settings
The mobile units are pre-set for optimum ease of operation. You can change these settings indi-
vidually for each mobile unit.
When this tone is activated, a tone is heard whenever a key is pushed.
w§! Push enter and keys 3, 1.
The current setting is shown.
=or 1Push the 1 to activate ( initialization status)
Push the 0 to deactivate.
w Press the enter key.
When the tone is activated, every erroneous entry is signalled acoustically.
w§$ Push enter and keys 3, 4.
The current setting is shown.
=or 1Push the 1 to activate (initialization status)
Push the 0 to deactivate.
w Press enter key.
If this tone is activated, only correctly completed settings are acoustically signalled.
w§/ Push enter and keys 3, 7.
The current setting is shown.
=or 1Push the 1 to activate (initialization status)
Push the 0 to deactivate.
w Press enter key.
Advisory and Alarm Tones: Activate / Deactivate
Key Acknowledgment Tone: Activate / Deactivate
Negative Acknowledgment Tone: Activate / Deactivate
Positive Acknowledgment Tone: Activate / Deactivate
A
31 !
A
34 1
A
37 1
75
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Mobile Unit Settings
If this tone is activated, an alarm is sounded when the battery needs to be exchanged.
w§" Push enter and keys 3, 2.
The current setting is shown.
=or 1Press the 1 to activate (initialization status).
Press the 0 to deactivate.
w Push enter key.
If this tone is activated, the range limit is signalled.
w§§ Push enter and digit keys 3, 3.
The current setting is shown.
=or 1Push the 1 to activate (initialization status).
Push the 0 to deactivate.
w Press enter key.
If the tone is activated, an acoustic signal is heard when the mobile unit re-enters the base sta-
tion range.
w§% Push enter and keys 3, 5.
The current setting is shown.
=or 1Push the 1 to activate (initialization status).
Push the 0 to deactivate.
w Press enter key.
Battery Alarm Tone: Activate / Deactivate
Range Alarm Tone: Activate / Deactivate
Synchronization Tone: Activate / Deactivate
A
32 1
A
33 1
A
35 1
76
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K06.FM
Operation with Standard Mobile Unit Mobile Unit Settings
This procedure accomplishes the following:
a) Reset to initialization status: b) Delete:
Mobile unit is ON.
w Press enter key.
( öPush the 1 and speed dial key.
Enter mobile unit PIN.
o Every digit entered replaces one dash
on the screen.
wPress enter key.
The settings are reset / deleted.
Note:
The mobile unit PIN is not deleted or reset.
Resetting the Mobile Unit to Initialization Status
Repeat dial memory
Speed dial memory
Tone ring volume
Tone ring pitch
Battery alarm tone
Range alarm tone
Synchronization tone
Automatic call acceptance
Acknowledgment tones
C
A
C
D
A
C
D
1____z
A
C
D
1 _z
C
77
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Using the Menu
The bottom line of the Comfort mobile unit display has two
fields with dark backgrounds. These show the features, which
are based on the status.
These features can be activated, when needed, using the dialog
keys below them.
Example:
To set up a consultation call, use the dialog key ä for the fea-
ture “CONSLT.”
In the description below, the name of the feature is used instead of the term dialog key. To acti-
vate a specific feature, press the dialog key below it.
The menu key ßis found in the middle, between the two dialog keys. With this, you can easily
activate menus for switching and for setting functions, either in idle status or during a call.
The main menu is at the lef ft of the display. This appears a ter the
F-key is pressed in idle status.
Three lines of the menu appear on the display. The entire menu
appears below.
The top line has a dark background.
Using the dialog key below “OK,” you can select this feature .
Using the dialog key below “NEXT,” you can scroll through the
menu. Each menu line moves up one line, thus displaying the
other menu lines.
In order to select a function using the dialog key “OK,” you must
scroll with NEXT” until the desired function is highlighted (dark
background).
Using the dialog key “NEXT,” you can scroll through the entire
menu.
The line with “- - - -” indicates the end of the menu.
Using the Dialog Keys
Using the Menu
The Entire Menu
External 1
0123456
F
CoNSLT.
Dialog keys
MUTE
Telephone Book
OKNEXT
F
Number redial
Telephone lock
Number redial
Telephone lock
Tones
Settings
Search station
Service
- - - - - - - - -
Tel.book
78
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Using the Menu
The menu structure for settings is set up as a hierarchy. Generally, settings are first made in idle
status. Additional settings options are also offered in other operating statuses (see “Status-
Dependent Menus“).
You can move to the desired setting step by step. The ßkey also allows you to scroll backward
through the menu levels (Main Menu - Service - System Settings - Equipment Data). Thus, you
can scroll back quickly through the levels.
If you want to terminate the process -- from any point within the menu structure -- without
changing anything, push the connect key gonce, or if necessary twice.
Your Comfort mobile unit initiates an automatic cancel after 30 seconds if you do not push any
key within this time.
Example:
In order to program call forwarding, for instance, the following steps must be carried out (from
idle state): Push the ß key; go to the “Service” menu from the main menu; from the Service
menu, select “Forward.ON.”
Below is a rough overview of the menu structure for the system settings:
Menu Structure for System Settings
Telefonbuch
Cancel registr.
System setting
- - - - - - - -
Duration/Units
Call barring
Change sys.code
System lock
Initialisation
Line data
Equipment data
- - - - - - - -
Service menu
ß
Idle State
Call pickup
Access rights
a/b line
- - - - - - - -
Equip. data
OK
NEXT
Number redial
Telephone lock
Tones
Settings
Search station
Service
- - - - - - - -
Main menu
NEXT
NEXT
OK
OK
NEXT
Menu for system
settings
ß
ß
ß
Telephone book
Forward.ON
Sys cd/Mn sys cd
Autom.seizure
79
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Using the Menu
Using the ß key, appropriate menus can also be activated from different operating statuses,
such as call status, internal call, external call or consultation status.
Example 1 “In Internal Call”
You are engaged in an an internal call...
Push.
Menu appears (Entire menu at left).
You can select appropriate functions with
“NEXT” and then confirm with “OK.
Example 2 “External Consultation in External Call
You are engaged in an external call...
Push this to set up an
external consultation call.
.
Push.
You can select appropriate functions
with “NEXT” and
confirm with “OK.“
Status-Dependent Menus
Internal
Call with 2
MUTE CONSLT.
ß
Handset Volume
Telephone book
OK
Ext. consultat’n
NEXT
Handset Volume
Telephone Book
Ext. Consultation
-------------------------
External 1
00:01:01
CONSLT.
MUTE
CONSLT. External 2
Please dial
TEL.BOOK REDIAL
ß
Resume
MUTE
OKNEXT
Handset volume
Resume
Mute
Handset volume
-------------------------
Telephone book
80
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Standard Settings
For your own protection, you can enter a new four-digit system code for the system. This pro-
tects your settings and prevents registration of additional mobile units.
All entries are carried out from a mobile unit. At the time of initialization, the system code is set
at “0000“.
The Comfort mobile unit is in idle status.
Push this key; main menu appears..
Scroll with NEXT ...
Until “Service“ appears in the 1st line of the
main menu and ...
select “Service” with OK .
The next menu level appears.
Scroll with NEXT...
until “System settings” appears in the 1st
line of the menu and
then select with OK.
Enter the four-digit system code
if necessary, correct with .
Scroll with NEXT...
until “Change sys. code” appears in the 1st
line
and then select with OK.
Enter new system code, please be sure to
note this number!
Every digit entered replaces one dash
if necessary, correct with .
Complete the entry.
Repeat the new system code.
Every digit entered replaces one dash..
Push this key to complete the entry.
Note:
If you have entered an erroneous system code, a negative acknowledgment tone will be
signalled.
If you forget the system code, it will be necessary to disassemble the device. Forgetting the
system code is like losing a key. If this happens, please get in touch with your vendor.
Enter / Change System Code
a
ß
Telephone book
Number redial
OK
Telephone lock
NEXT
Service
- - - - - - - -
OK
Telephone book
NEXT
Service
System settings
Change Sys. code
Forwarding ON
Cancel registr.
OK
System settings
NEXT
System code
Enter:
* * _ _
OK
System settings
- - - - - - - -
OK
Call Forward. ON
NEXT
Sys cd/Mn sys cd
Duration/Units
OK
Call barring
NEXT
o Enter
new sys.code:
4 7 _ _
OK
OK
o
Repeat
new sys. code:
* * _ _
OK
OK
81
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Standard Settings
If you would like the display texts to appear in a language other than the one which is already set
(German), you can select between either German, English, French, Italian or Spanish for each
device.
The Comfort mobile unit is in idle status.
Push the F- :key; main menu appears
Scroll through main menu with NEXT
until “Settings” appears in the 1st line,
and select “Settings” with OK.
Select “Language” using same procedure.
Scroll with NEXT and
select desired language with OK.
You can set the tone ring individually, including the volume, pitch and melody. The tone ring
volume has 7 levels, the tone ring pitch (tone sequence frequency) has 10 levels and the tone
ring melody has 10 levels.
The Comfort mobile unit is in idle status
..
Push the F- :key; main menu appears
Scroll through main menu with NEXT ..
.
until “Settings” is on the 1st line,
and select “Settings” with OK.
Select “Tone ringing” in the same manner
from the next menu.
Menu appears (entire menu at left).
Using NEXT / OK, you can select and
edit the following options
:
Using NEXT, select the desired volume level
(you can hear the volume while doing this) and
store with SAVE.
Tone ringing can be switched off completely.
.
Set in the same manner as tone ring volume.
Set in the same manner as tone ringing volume.
Set Dialog Language
Set Tone Ringing for Mobile Unit
a
ß
Telephone book
Number redial
OK
Telephone lock
NEXT
Settings
Language
Settings
Search station
OK
Service
NEXT
Active: German
New: English
OK
New: French
NEXT
a
Telephone book
Number redial
OK
Telephone lock
NEXT
ß
Settings
Search station
OK
Service
NEXT
Settings
P
Tonering.volume
Tonering.pitch
Tonering.melody
- - - - - - - - - - -
Tone ringing
Tonering.volume
Tonering. pitch
Tonering.melody
Handset volume
Tone ringing
OK
Display contrast
NEXT
Tonering.volume
Tonering.pitch.
Tonering.melody
NEXT OK
SAVENEXT
Tonering.volume
82
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Standard Settings
For your protection, you can enter a new four-digit PIN for each mobile unit. This protects your
settings such as ,for example mobile unit lock, and your stored personal data. The mobile unit
PIN setting at initialization is “0 0 0 0.
The Comfort mobile unit is in idle
status.
Push this key; main menu appears..
Scroll with NEXT ...
until “Telephone lock” appears in the
1st line of the main menu...
then select “Telephone lock” with OK.
Enter 4-digit mobile unit PIN
After confirming with OK, the
following menu appears
Scroll with NEXT ...
until “Change PIN” appears in the
1st line of the menu and...
then select with OK .
Enter new PIN, please note this number!
Every digit entered replaces one dash
if necessary, correct with .
Complete entry.
Repeat new PIN.
Every digit entered replaces one dash..
Push this key to complete the entry.
Note:
If you have entered an erroneous PIN, a negative acknowledgment tone is signalled.
If you forget your PIN, it will be necessary to disassemble your device. Forgetting the PIN is
like losing a key. If this happens, please get in touch with the vendor of your telephone.
Enter / Change Mobile Unit PIN
a
ß
Telephone Book
Number redial
OK
Telephone lock
NEXT
Telephone lock
Tones
OK
Settings
NEXT
Telephone lock
Change PIN
Lock ON
Hotline no.
OK
Del.Hotline No.
NEXT
Enter
PIN:
* * _ _
Change PIN
- - - - - - - -
OK
Lock ON
NEXT
oEnter
new PIN:
4 7 _ _
OK
o
Repeat
new PIN:
* * * *
SAVE
SAVE
83
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Standard Settings
In order to be able to use the call pickup, it must be activated (status at initialization). The activa-
tion or deactivation of call pickup is valid for the entire system. Details on how to use call pickup
are found on page 87.
1. In idle status, push the ßkey and select “Service” from the main menu.
2. In the service menu, select “System settings” and enter the system code
(see also page 115).
After the correct system code is entered,
the following display appears:
Scroll with NEXT...
until “Equipment data” appears in the 1st
line
and then select with OK.
Scroll with NEXT...
until “Call pickup” appears in the 1st line
and
then select with OK.
Push OK if you only want to view
or
use OFF to deactivate call pickup.
Activate / Deactivate Call Pickup
Sys cd/Mn sys cd
OK
Duration/Units
NEXT
Call barring
Equipment data
Call pickup
OKOKOKOK
OKOK
Autom. seizure
OK
Call pickup
NEXT
Access rights
Call pickup
activated
OKOFF
OFF
84
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Standard Settings
Push the gkey to be able immediately seize an external line (status at initialization). If this
function is deactivated, you must first dial a zero to place an external call.
This setting can be adjusted for every internal station.
1. In idle status, push the ßkey and select Service” from the main menu.
2. In the service menu, select “System settings” and enter the system code.
(see also page 115).
After the correct system code is entered,
the following display appears:
Scroll with NEXT...
until “Equipment data” appears on the 1st
line and
then select with OK.
Select Autom. seizure” with OK.
A list of the internal numbers appears.
Push OK if you only want to view
or
Activate / Deactivate “Automatic seizure“ for Internal Station
Stipulate by deleting or entering the desired
internal numbers; here,
1 to 4; if necessary, correct with .
Complete with SAVE.
Activate / Deactivate Automatic Line Seizure
Sys cd/Mn sys cd
OK
Duration/Units
NEXT
Call barring
Equipment data
Autom. seizure
Autom.seizure
OK
Call p ickup
NEXT
COS
Automatic
seizure forInt.:
OK
1 2 _
1
...
8
Automatic
seizure for Int.:
1 2 3 4
SAVE
SAVE
85
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Standard Settings
The mobile unit is in idle status.
Push the F-key; main menu appears.
Scroll through main menu with NEXT ...
until “Settings” appears on the 1st line and
then select with OK.
The menu for the mobile unit settings
appears (entire menu at left).
Using NEXT / OK, you can select and edit
the following options:
Handset volume Set the handset volume
(3 levels possible).
Tone ringing Set the tone ringing volume,
(7 levels possible)
You can hear the level during the setting procedure.
The pitch (10 levels) and melody (10 levels) of the tone ring can
be set in the same manner.
Display contrast Set display contrast
(6 levels possible).
Register See „Registering the Comfort Mobile Unit at a Base Station“ on page
24
Language Set the language;
5 different languages can be set:
German, English, French, Italian, Spanish.
Auto.backlight Activate / deactivate automatic display- back-
light
Initial. status Set the initialization status of mobile unit;
this setting is protected by the mobile unit
PIN. PIN setting and telephone book entries are retained!
Mobile Unit Settings
a
ß
Telephone book
Number redial
OK
Telephone lock
NEXT
Handset volume
Tone ringing
Display contrast
Register
Language
Auto. backlight
Multicell config
Initialisation
- - - - - - - -
Settings
Handset volume
Tone ringing
OK
Display contrast
NEXT
Handset volume
OKNEXT
Tonering. volume
OKNEXT
Display contrast
OKNEXT
Active: German
New: English
OK
New: French
NEXT
Auto. backlight
activated
OFF
OK
86
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Incoming Calls
An incoming call (external, internal) is signalled acoustically via the tone ring and visually on the
screen of the mobile unit.
Display Before Call Pickup
Incoming external call:
(here, on line 1)
Push this to switch off tone ring.
You can still accept the call, as long as it
remains visible on the screen.
Incoming internal call:
(here, mobile unit 2) Display blinks.
Accept the Call
either
by “picking up” the mobile unit from the
charging unit,
or
by pushing the connect key if the mobile
unit is not in the charging unit.
Display After Call Pickup
external call
(here, line 1)
internal call (here, mobile unit 2)
To Terminate the Call
Either
push the connect key
or
return the mobile unit to the charging unit.
Display After End of Call
Accept / Terminate Call
RING OFF
Call from Ext 1
RING OFF
Call from Int 2
RING OFF
c
g
External 1
CONSLT.
MUTE
Internal
call with 2
MUTE CONSLT.
g
a
TEL.BOOK
Station 1
REDIAL
87
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Incoming Calls
You can pick up an external call within your call group even if the call is not signalled on your
mobile unit (for example, in the case of call forwarding, page 105).
In order to do this, call pickup must be activated (see page 83).
Push the connect key
Push this key,
to pick up the external call.
or
if “Automatic line seizure“ (see page 84) is activated:
Push the-0 key, to seize another telephone
line..
Push this key,
to accept the external call.
Call Pickup
g
Pickup
Call on Ext 1
EXT 2
PICKUP Ext 1
CONSLT.
MUTE
@
External 2
REDIAL
Please dial
TEL.BOOK
External 2
PICKUP
Call on Ext. 1
MUTE
PICKUP External 1
CONF.
TOGGLE
Ext. 2 waiting
88
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Incoming Calls
The call waiting tone signals that an external call is waiting while you are engaged in another call.
If you answer the external call while you are engaged in an internal call, the internal call is termi-
nated.
You are engaged in an internal call and hear
the call waiting tone.
Push this button to accept the external call
immediately
or
Push the connect key to terminate the on-
going call.
You will hear the external call and can
accept it .
The call waiting tone signals that a call is waiting while you are engaged in another call. The call
waiting feature can be activated and deactivated.
You are engaged in an external call and hear
the call waiting tone.
Push this to pick up the external call imme--
diately (the current call is then placed on
hold).
You can now toggle between the calls
Push this button.
or set up a 3-way conference
Push this button
or return to the original call
Push.
The second call is terminated thereby.
Answer Call Waiting During an Internal Call
Answer a Call Waiting During an External Call
b
Internal
Call from Ext. 1
PICKUPMUTE
PICKUP
g
Call from Ext. 1
RING OFF
b
External
MUTE PICKUP
External call
PICKUP
External 1
Ext. 2 waiting
TOGGLE
CONF
TOGGLE
External 2
Ext.1 waiting
TOGGLE CONF
CONF
Conference
CONF. END
External
CONSLT.
00:11:01
89
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Outgoing Calls
After putting the base station and Comfort mobile unit into service, you can generally place calls
with a mobile unit which is switched ON.
The Comfort mobile unit is in
idle status.
Push connect key.
You will hear the dial tone.
Automatic Line Seizure Activated (Initialization Status)
External telephone line is automatically
seized.
No Automatic Line Seizure Activated
Internal dial tone can be heard
Push EXT1/ EXT2 or 1/2 key
to seize specific line
or
Push this key
first available line is seized
then
Push the digit keys to dial external number.
It is displayed in enlarged form, here
12345678..
You hear the ring tone.
The subscriber answers.
You carry on the external call...
External Dialing with Dialpad
a
Station 1
TEL.BOOK REDIAL
g
External 1
Please dial
TEL.BOOK
REDIAL
Please seize
EXT1
EXT2
line
EXT1 EXT2
External 1
Please dial
TEL.BOOK
REDIAL
=
o
External 1
12345678
PAUSE
External 1
00:01:01
CONSLT.MUTE
b
Continued
90
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Outgoing Calls
To Terminate the Call:
Push the connect key or return the mobile
unit to the charging unit.
The length of time which elapsed during the
call appears on the display.
After 4 seconds, the screen
again shows the following.
Telephone Line is Busy:
If the telephone line is already being used
by another Gigaset station, you will hear a
busy tone and see the display:
or, for example.
Mobile Unit not Fully Trunk Authorized:
If, for example, your mobile unit is not set
for “full trunk authorization,” then you
cannot make external calls.
(See „Set the COS for Internal Stations“ on
page 113.)
00:03:21
g
Station 1
TEL.BOOK REDIAL
External line
busy
External 1
busy
No
access rights
91
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Outgoing Calls
En-bloc dialing allows you to view the external telephone number which you have entered before
the number is dialed and to correct it, if necessary.
The Comfort mobile unit is in idle status
.
Automatic Line Seizure Activated
Enter the external telephone number.
It is displayed in an enlarged form; here,
1234567.
if necessary, correct with .
Push connect key within 30 seconds.
You will then hear the dial tone, and the
number can be dialed.
The subscriber answers.
You carry on the external call...
No Automatic Line Seizure is Activated
Enter the telephone number:
First enter the line code 0, 1 or 2
here, the 0; now enter the tel. number
Push the connect key
You will then hear the dial tone, and the
telephone number is dialed
To Terminate the Call:
Push the connect key, or return the mobile
unit to the charging unit.
You will see the length of time which
elapsed during the call.
Note:
En-bloc dialing can contain a maximum of 22 characters.
External En-Bloc Dialing with Dialpad
a
TEL.BOOK
Station 1
REDIAL
o
1234567_
WAH
PAUSE
g
Extern 1
PAUSE
12345678
MUTE
External 1
CONSLT.
00:01:02
b
01234567
WAH
PAUSE
o
g
01234567_
WAH
PAUSE
Extern 1
g
00:03:21
92
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Outgoing Calls
Number redial allows you to automatically redial the last external number dialed from the mobile
unit.
The Comfort mobile unit is in idle status
.
Push this key to activate
number redial.
The telephone number is shown on the dis-
play; here, 12345678.
Push this key to start dialing
The subscriber answers.
You carry on the external call.
To Terminate the Call:
Push the connect key, or return the mobile
unit to the charging unit.
or aOn the display, you will see the time
elapsed during the call.
Note:
The number redial memory can contain a maximum of 22 characters.
Every new telephone number entered overwrites the previous one.
After pushing DIAL, you can manually add suffix numbers. The suffix digits are not stored in
the number redial memory.
The number redial memory is erased if the device is switched off or the battery removed.
Number redial allows you to automatically dial the most recently dialed external number.
The Comfort mobile unit is in
idle status.
Push this key to activate the number
redial feature.
The phone number is shown on the screen;
here, 12345678.
Push this key to start dialing
The phone number is dialed.
The subscriber answers.
You carry on the external call.
Number Redial
Number Redial as En-Bloc Dialing
a
TEL.BOOK
Station 1
REDIAL
REDIAL
DIAL
12345678
DIAL
Extern 1
12345678
PAUSE
00:03:21
b
g
a
TEL.BOOK
Station 1
REDIAL
REDIAL
DIAL
12345678
DIAL Extern 1
12345678
Pause
93
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Outgoing Calls
The Comfort mobile unit is in
idle state.
Push internal key.
Your station number is displayed;
here, 1.
Enter the desired internal station number,
i.e. push one of the digit keys between 0
and 9; here, the 2.
The internal station number which was
dialed is displayed; here, for example, 2.
or
Collective call:
Push the dialog key.
or
Push the star key
You will hear the internal ring tone.
All registered internal stations, mobile units
or auxiliary devices are displayed
and rung.
The other party answers, having already
seen on the screen which station is
calling.
You carry on the internal call.
To Terminate the Call:
Push the connect key, or return the mobile
unit to the charging unit.
After 4 seconds, the screen returns to the
idle status display.
Note:
Stations 0 to 9 are available on your Gigaset 1054.
T To view the internal station number, push the internal key. erminate by returning the mobile
unit to the charging unit, or by pushing the connect key.
Internal Dialing to Another Mobile Unit or Auxiliary Device
a
TEL.BOOK
Station 1
REDIAL
ü
Internal
Your own no.: 1
Coll.call
@ 9... Internal 1
Calls Internal 2
Coll.call
Internal call to
2 3 4
*
Internal
MUTE CONSLT.
call with 2
b
g
TEL.BOOK
Station 1
REDIAL
94
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Outgoing Calls
You can enter up to 100 names and accompanying telephone numbers in the telephone book
(depending on the length of the number or the name). Saving and administering the entries is
described on page 99.
The stored names can be found either via scrolling or by entering the letters of the name, using
the alphanumeric keyboard on your Comfort mobile unit.
The Comfort mobile unit is in
idle state.
Push this key to access the telephone book.
Find the name by scrolling
or
Entering Letters:
By entering the letters, for example
The letter B: Push the 2 twice, or
The letter C: Push the 2 three times quickly,
or
The letter D: Push the 3 once.
Push this key to dial the number
of the station selected.
You hear the ring tone.
The station answers..
You carry on the external call...
To Terminate the Call:
Push the connect key, or return the mobile
unit to the charging unit.
On the screen, you will briefly see the time
elapsed during the call.
Note:
If the name search does not find any such entries, an error tone is signalled.
Dialing from the Telephone Book
a
Station 1
TEL.BOOK REDIAL
TEL.BOOK
NEXT
ANTON
BERTA
C‡SAR
DIALNEXT
BERTA
C‡SAR
DANIEL
DIALNEXT
22 BERTA
C‡SAR
DANIEL
DIALNEXT
DIAL External 1
12345678
PAUSE
b
External 1
00:00:21
CONSLT.
MUTE
g
00:03:21
95
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit During the Call
You can place an ongoing call on hold in order to, for instance, hold a consultation with someone
in the room.
Placing an Internal Call on Hold:
You are engaged in an internal call.
Push this key.
The internal station 5 is then placed on
hold.
Push this in order to retrieve the call from
hold .
Push this key.
Place External Call on Hold:
You are engaged in an external call.
Push internal key.
This places the external station on hold.
Push this to retrieve the call which was on
hold.
Push this button.
Note:
In the case of an external call which is placed on hold, the call charges and length of call dis-
play remain, in the background.
Call on Hold
b
Internal
MUTE
call with 5
CONSLT.
üIntern
Intern 5 wartet
R
{
CKNAH
RESUME
RESUME
e
or
Internal
MUTE
call with 5
CONSLT.
b
External 1
012345678
CONSLT.
MUTE
ü
Ext. 1 waiting
R
{
CKNAH
RESUME
RESUME
e
or
External 1
012345678
CONSLT.
MUTE
96
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit During the Call
If your Gigaset 1054 is connected to a telephone line with tone dialing, then the following
explanation has no relevance for you .
If your Gigaset 1054 is connected to a telephone connection with pulse dialing (DPS), you have
the option of temporarily switching your Gigaset 1054 from DPS to tone dialing (DTMF) during a
call.
By switching the dialing mode from pulse to tone dialing, you can use the dialpad of your mobile
unit to enter information during a call, for example to query an answering machine or a voice
mailbox or to take advantage of services offered by the German Telekom AG such as “City Call”
and “Scall.”
At the time of initialization, tone dialing is pre-set.
You are engaged in an external call and want
to switch to tone dialing.
Push the F- .key; the menu appears
Scroll with NEXT until “Temp. tone
on“ appears on the 1st line
and then select with OK .
Push this key to deactivate
tone dialing.
Note:
After the end of the call, the tone dialing function is automatically deactivated.
Temporary Switchover to Tone Dialing
b
External 1
CONSLT.
12345678
MUTE
ß
Ext.Consultation
Handset volume
Telephone book
OK
NEXT
Handset volume
Telephone book
Temp.tone on
- - - - - - - - - - - - - -
Ext.consultation
on
Temp. tone
External 1
12345678
MUTE
DTMF OFF
DTMF OFF Temp. tone
off
97
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit During the Call
You can change the volume of your mobile unit during a call. There are 3 levels
(1=normal to 3=loud).
Push this key; a menu appears.
Push this to select the “Handset volume.”
Display shows the current setting; here,
level 1 (normal).
Push this if you do not want to change the
current setting.
or Change Handset Volume:
Select the desired volume level; here, level
2.
Second level is dark.
Push this to save the setting.
If you want to prevent your call partner from hearing you temporarily, (for example, if you want to
consult with someone in the room), then you can switch the mobile unit temporarily to mute
during an external call.
You are engaged in an external call ...
Mute On:
Push this key.
The call partner cannot hear you.
You can consult with someone in the room.
Mute Off:
Push this key.
Your call partner hears you again.
You can activate/deactivate the mute
function repeatedly.
You continue with the call ...
Change Handset Volume
Mute Function
ß
Telephone book
OK
Cancel call park
NEXT
Handset volume
OK
Handset volume
OK
NEXT
OK
NEXT
SAVE
Handset volume
SAVE
NEXT
b
External 1
00:01:34
CONSLT.
MUTE
MUTE External 1
00:01:35
CONSLT.
MIC. ON
MIC.ON External 1
00:02:38
CONSLT.
MUTE
b
98
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Telephone Book
The following explains how you can enter letters and digits to administer the telephone book.
After selecting, for example, “New entry in the telephone book menu, enter the telephone
number. The dialpad automatically switches to letter entry so that you can enter the name.
Entering Letters:
The dialpad (digit keys) is used as an alphabetical keyboard for the entry of names into the tele-
phone book. This entry modus is only available if you are in the “Telephone book” menu.
The letters for each digit key are printed on the keys:
1 2 3 4 5 67 8 9 @
The @ key has the following functions:
Space , period .“ and dash “-.
The 1 key is configured with the letters Ä, Ö and Ü. These letters can be entered beginning
with the 1st letter of the name entry.
In addition, you can enter the following: “Star“ *and “Pound“ #.
Entering Digits:
1, 2 to @ Enter digits (not as the first entry in a name) by pressing
the appropriate dialpad key four or five times.
Sorting Sequence:*, #, A, Ä
Telephone numbers which you prefix with *and #will appear as the first entries in the tele-
phone book list, thus making them easy to sort and select. Use this for frequently-called num-
bers.
To enter letters or special symbols, proceed as follows:
Within 8 seconds, press the appropriate digit key repeatedly until the desired letter appears
on the display. The cursor blinks once (where entry appears) each time the key is pressed.
When the desired letter appears, wait until the cursor jumps to the next entry space.
Then enter the next letter.
Enter spaces by pushing the @key once.
Deleting Entries:
If you have entered a wrong letter or number, you can delete it by pushing the backspace key.
Each time this key is pressed, the last letter or digit entered is deleted.
Entering Names and Characters
99
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Telephone Book
Up to about 100 entries can be stored in the electronic telephone book of the Comfort mobile
unit (58 when all spaces are used; names up to 16 characters, tel.numbers up to 22 characters).
Before using the “Telephone book” menu, please read the chapter “Menu Techniques” which
describes how to enter digits and letters.
There are two ways to activate the telephone book.
If you want to dial a telephone number from the telephone book, use the dialog key “TEL.BOOK”.
If you want to make new entries, or change or delete entries, push the ß key and then select
the menu point “Telephone book”.
Dialing from the Telephone Book:
To dial, you can activate the telephone book
directly, using the dialog key TEL.BOOK
Push this key to dial the selected name
(page 94).
Editing the Telephone Book:
Push the F-key in idle state;
The main menu appears
In the main menu, select Telephone Book”
with OK
The menu to edit the telephone book
appears (entire menu is at left).
Using NEXT / OK, you can select and edit
the following options :
Dialing from the telephone book
(see also the corresponding procedure).
Enter new names with telephone numbers
in the telephone book.
First the telephone number ...
... then the name.
Entries are sorted alphabetically in the tele-
phone book.
Note:
Using the prefix, “* #“ or when entering the name, you can ensure that important
entries are placed at the beginning of your telephone book.
If no automatic line seizure is activated, the first digit entered
must be the line code (0,1 or 2)
Dialing Convenience with the Telephone Book
Station 1
TEL.BOOK REDIAL
TEL.BOOK
DIAL C‡SAR
DIALNEXT
BERTA
ANTON
ß
Telephone Book
Number redial
OK
Telephone lock
NEXT
Dial entry
New entry
Change entry
Delete entry
Delete tel.book
- - - - - - - - - - - - - - -
Dial entry
New entry
OK
Change entry
NEXT
Dial entry
New entry 01234567_
Tel. No.?
OK
01234567 Name?
BAIER_
SAVE
Continued
100
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Telephone Book
Change or view entry.
Scroll to names to be changed, using
NEXT, and select with OK.
First the telephone number is offered (for
changes).
(if necessary, delete with reverse)
... then the name.
Complete process with SAVE.
Delete entries individually.
Find / select entries to be deleted, using
NEXT.
Push this key.
The entry is deleted.
Deletes all telephone book entries at once..
This option is available only after entering
the mobile unit’s PIN.
Change entry BAIER
BRUNNER
OK
C˜SAR
NEXT
01234567_
BAIER
Tel No?
OK
01234567
BAIER_
Name?
SAVE
Delete entry
ANTON
BERTA
C˜SAR
DELETE
NEXT
DELETE
Delete tel. book entries
Delete all
in tel. book?
OK
NO
101
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Switching Functions
With this system, it is also possible to make consultation calls and to transfer an external call to
another internal station.
Activate Internal Consultation:
You are engaged in an external call.
Push this key;
The external call is placed on hold.
Enter the desired internal number; here, 3
or Ring all Internal Stations:
Push the star key to ring all internal stations
at once.
You will hear the internal ring tone, a station
answers; here, 3.
You are connected to the internal station.
Transfer Call:
Push connect key, or return the mobile unit
to the charging unit.
or Terminate Consultation and Continue External Call:
Push F-key ...
Menu appears.
Select “Resume” with OK
The external station is reconnected to you.
You continue with the external call.
Note:
After dialing the internal station number, you can immediately transfer the call by “hanging
up”, even before the internal station has answered.
If the station to which the call is being transferred does not answer within 30 seconds, recall
is activated.
Internal Consultation / Transfer of Call
b
External 1
00:12:10
CONSLT.
MUTE
ü
Ext. 1 waiting
R
ESUME
1
...
9
Int. 1 calling 3
Ext. 1 waiting
RESUME
*
Int. call to
Ext. 1 waiting
RESUME
0 3
Connection with 3
Ext. 1 waiting
CONF
TOGGLE
g
Station 1
TEL.BOOK REDIAL
ß
Resume
Call with 3
Ext. 1 waiting
CONF
TOGGLE
MUTE
OKNEXT
Handset volume
RESUME
Ext. 1
00:12:15
CONSLT.
MUTE
102
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Switching Functions
With this system, you can carry on a consultation call and transfer an external call to another
external station, if the 2nd telephone line is available.
Activate External Consultation:
You are engaged in an external call.
Push this key to activate external consulta-
tion .
Enter the desired external telephone num-
ber .
You will hear the ring tone, a station
answers.
You are connected to the external station.
Terminate External Consultation and Continue First External Call:
Push this key, menu appears
Push this to retrieve the consultation call
The first external station is now reconnec-
ted with you.
You continue with the first external call
.
or
Push this key, or return the mobile unit to
the charging unit.
You will receive a recall and can continue
with the original call after picking it up.
External Consultation / Transfer Call
External 1
00:00:39
CONSLT.
MUTE
b
CONSLT. External 2
Please dial
TEL.BOOK REDIAL
oExternal 2
3456789
TOGGLE PAUSE
External 2
Ext. 1 waiting
TOGGLE CONF.
ßResume
Mute
OK
Handset volume
NEXT
OK
External 1
00:03:45
CONSLT.
MUTE
g
External 1
CONSLT.
MUTE
103
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07A.FM
Operation with Comfort Mobile Unit Switching Functions
During a consultation call, you can toggle back and forth between the two established calls as
often as you like. External toggle is possible as long as the 2nd telephone line is available.
Toggle with Internal and External Stations:
You are engaged in an internal consultation,
call; the external call partner is placed on
hold.
You switch back to the original external call
partner.
Internal consultation partner 5 is waiting.
Push this to switch to the consultation call
etc...
Toggle Between External Stations:
You are engaged in an external consultation
call; the other external call is placed on hold
.
You switch back to the original external call.
External consultation partner 2 is waiting.
Press this to switch back to the consultation
call with external 2, etc...
Terminate Toggle:
Press this key; menu appears
Press this to terminate toggle
The external station is reconnected to you.
or
Press this key, or return the mobile unit
to the charging unit.
You receive a recall and can, after picking it
up, continue with the original call.
Note:
In this same manner, you can toggle between an internal call and an external consultation
call.
Toggle is also possible using the ü#keys.
It is also possible to set up a 3-way conference from within the consultation status.
Toggle
b
Connection with 5
TOGGLE CONF.
Ext. 1 waiting
TOGGLE External 1
TOGGLE KONF.
Int. 5 waiting
TOGGLE
b
External 1
TOGGLE CONF.
Ext. 2 waiting
TOGGLE
External 2
TOGGLE CONF.
Ext. 1 waiting
TOGGLE
External 1
TOGGLE CONF.
Ext. 2 waiting
Connection with 5
TOGGLE CONF.
Ext. 1 waiting
ß
Resume
MUTE
OK
Handset volume
NEXT
OK
g
Extern 2
CONSLT.MUTE
Recall
RING OFF
105
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07B.FM
Operation with Comfort Mobile Unit Switching Functions
Using internal call forwarding, you can forward external calls to other internal stations. The call
can only be forwarded to internal stations which have call forwarding activated.
The mobile unit is in idle status
.
Push this key; the main menu appears.
Scroll through main menu with NEXT...
until “Service“ is in the 1st line; select this
with OK.
Scroll in the next menu with NEXT until
“Call forward.ON” appears in the 1st line;
select this with OK.
Select “Internal” with OK.
Push this to select the internal station to
which the call should be forwarded.
Push this to set the internal station; here,
the 0.
Push this to select the number of tone rings
before forwarding should be carried out..
Push this key to set the number of tone
rings; here, 3 (status at initialization).
Deactivate Internal Call Forwarding:
Push the connect key.
“Fnct. set. act.“ means that a system func-
tion is set, for example, internal call forward-
ing.
Push this key.
Menu for setting the system functions
appears.
Select “Set system fnct.“
Select “Int. forwarding.
Push this to view the current call forwarding
setting without deactivating it.
or
This deactivates call forwarding .
Activate/ Deactivate Internal Call Forwarding
a
Telephone Book
OK
Number redial
NEXT
Telephone lock
ß
Service
Call forward.ON
Internal
Call forward. ON
OK
Cancel registr.
NEXT
System settings
Internal
OKNEXT
- - - - - - - -
To internal 0
OK
To internal 1
NEXT
To internal 2
NEXT
OK
NEXT Active:3 cycles
OK
New
NEXT
New 0 cycles
1 cycle
:
:
OK
g
Fnct. set. act
Please dial
TEL.BOOK REDIAL
ß
Set system fnct.
OK
Handset volume
NEXT
Telephone book
Set system fnct.
Int. forwarding
OKNEXT
-------------
Int.forwarding
OK
OFF
Call forwarding
OK
OFF
to internal 2
106
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07B.FM
Operation with Comfort Mobile Unit Switching Functions
The door interphone should be connected only to the auxiliary device connection with the inter-
nal station number 9. This feature is only available for stations which are listed in the door inter-
phone ring allocation list.
Tone ring is signalled by the door interphone
(3 short tones).
Push the connect key.
You are connected to the door interphone.
Push this to open the door.
The door opener is activated for 3 seconds.
You can activate the door opener repeatedly
.
The connection to the door interphone
remains.
To terminate, push the connect key.
Connection to the Door Interphone
Doorstation call
g
Internal
connection with
doorstation
MUTE
DOOR OPE
DOOR OPEN
Internal
door open
Internal
connection with
doorstation
MUTE
DOOR OPE
g
107
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07B.FM
Operation with Comfort Mobile Unit Charges, Call Length
You can use any mobile unit to view the total charges as well as the charges for the most recent
call. The charge total includes only the charges occurring on that particular mobile unit. The set-
ting of the unit cost is described on pages 108 and 109.
The setting for all mobile units and auxiliary devices -- whether for call length, units, or charges --
is carried out on the mobile units. In addition, you can stipulate whether the previously-incurred
call charges or units should be displayed before the beginning of the call.
The charges per mobile unit or auxiliary device and the total call charges for all devices can also
be deleted, using the mobile unit.
Display of Units
(Unit cost=0)
Display of units remains visible for about 4
seconds after the end of the call.
Display of cost in DM
(Unit cost >0)
Display of cost remains visible for about 4
seconds after the end of the call.
Display of Call Length
If the call length recording feature is activated, the recording begins immediately upon connec-
tion of the call.
Display:
After the connection is terminated, the call
length display clock stops; it remains visible
on the display for about 4 seconds.
Display of Charges / Display of Call Length
External 1
0000026 00008
CONSLT.
MUTE
0000026 00008
Total Individual
External 1
23.07 2.07
CONSLT.
MUTE
2.07
Total Individual
23.07
00:07:59
Hours
Minutes
Seconds
108
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07B.FM
Operation with Comfort Mobile Unit Charges, Call Length
In order to be able to use this feature, you must first apply to the German Telekom AG to have
your phone lines set up for “unit measurement”.
Your Gigaset 1054 can display either the telephone units, the charges or the call length. At the
time of initialization, the call length display is activated.
The type of display selected appears on all mobile units.
The Comfort mobile unit is in idle state.
Push this button.
The main menu appears.
Scroll through the main menu with lNEXT
until “Service“ is in the 1st line; then select
“Service” with OK.
In the next menu, scroll with NEXT until
“System settings” is in the 1st line; select
with OK.
Enter the 4-digit system code after “Sys-
tem settings; if necessary, use to cor-
rect.
Confirm system code with OK.
Select “Duration/Units” with OK.
The menu for setting call length display or
charge data appears. (Entire menu at left).
Using NEXT / OK, you can select and edit
the following options:
Activate / deactivate display of the call
length.
Activation of the call length display automat-
ically deactivates any call charge display
which might be on!
Activate / deactivate the call charge units
Activation of the call charge display auto-
matically deactivates any call length display
which might be on!
Activate and Deactivate Call Length and Call Charge Display / Set the Unit Cost
a
Telephone Book
OK
Redial
NEXT
Telephone lock
ß
- - - - - - - -
ChargFactor-.--
ChargFactor---
Seize displ. ON
Total
Total per unit
Call duration
Units/Charges
Service
System settings
Units/Charges
Length/Units
Call forward. ON
OK
Cancel registr.
NEXT
System settings
system code:
Enter
OK
- - - -
Sys cd/Mn sys cd
OK
Duration/Units
NEXT
Call barring
Duration of Call
OK
Units/Charges
NEXT
ChargFactor-.--
Call duration Recording call
OFF OK
duration Ext1
activated!
Units/
ON OK
Charges Ext1
deactivated!
Continued
109
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07B.FM
Operation with Comfort Mobile Unit Charges, Call Length
Stipulate unit cost with decimal point.
Any time the unit cost is changed, the total
charges are reset to zero.!
Thus, any change in the unit cost should
only be carried out at the end of a billing
period..
Stipulate unit cost without decimal point.
Any time the unit cost is changed, the total
charges are reset to zero.!
Thus, any change in the unit cost should
only be carried out at the end of a billing
period.
This display can also be used to display
charges in a foreign currency..
Activate / deactivate charge display of the
preceding call. (The charge display must be
activated!)
If this feature is activated, then the charges
for the preceding call are displayed after the
line is seized. This is particularly useful, for
example, in hotels or inns which wish to
view a guest’s call charges. For resetting
options for the call charges, see “Delete
totals”
View or delete individually the call charges
per telephone line..
Using OK, the totals for both telephone
lines can be displayed individually.
The last sum in the list is the total for both
telephone lines.
View or delete individually the total charges
per registered mobile unit or connected aux-
iliary device, i.e. per internal station.
If the unit cost is entered for the first time or changed, all previous individual and total entries
are deleted.
If you want to have the units displayed again, enter “0.00” as the new unit cost.
The unit cost can be programmed for any number up to 9.99 or 999, and is then valid for all
stations.
ChargFactor-.-- Charge factor
SAVE
1.--
ChargFactor--- Charge factor
OK
---
Seize displ. ON
Charge display
after seizuree
activated
Total
DELETENEXT
Total 12.20
Ext1:
DELETENEXT
Total charges
123.50
Total per unit
INT1:
INT2:
DELETENEXT
56.50
4.30
111
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07B.FM
Operation with Comfort Mobile Unit Lock
By storing restricted numbers, you can ensure that telephone numbers which begin with one of
these restricted numbers cannot be dialed. Thus, for example, if “00” is stipulated as a
restricted number, no international calls can be made. You can store up to three restricted num-
ber (each with 1 to 8 characters) for each individual mobile unit.
1. In idle status, push the ßkey and select “Service” from the main menu.
2. In the Service menu, select “System settings” and enter the system code.
(see also page 115).
After the correct system code is entered,
the following display appears:
Scroll through the next menu, using NEXT,
until “Call barring” appears in the 1st line;
select “Service” with OK.
Scroll through the menu with NEXT and
then, with OK, select an internal station
(e.g. “Lock Int0“) for which the telephone
number lock should be set up.
The menu for setting the restricted numbers
appears (entire menu at left).
Using NEXT /OK, you can select and edit
the following options:
Activate / deactivate the lock via
restricted numbers.
After “Lock ON” is selected, the message
at right appears.
View / change restricted numbers.
After the restricted number is selected, it
can be changed or viewed with OK
Enter new restricted numbers.
Delete individual restricted numbers.
Enter, View, Delete Restricted Numbers / Activate or Deactivate Lock
OK
Duration/Units
NEXT
Call barring
Sys cd/Mn sys cd
Call barring
Lock ON
Lock No. list
New entry
Delete lock no.
- - - - - - - -
Lock Int0
Delete all
OK
Lock Int0
NEXT
Lock Int1
Lock ON
OK
Lock No. list
NEXT
New entry
Lock ON Lock numbers
activated
for Int0
Lock No. list No.1: 0180_
OK
New entry No.1: 018_
SAVE
Delete lock no. No.1: 0
DELETE
No.2: 0190
NEXT
No.3: 0180
112
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07B.FM
Operation with Comfort Mobile Unit Lock
Using this function, all restricted numbers are deleted at once.
1. In idle status, push the ßkey and select “Service” from the main menu.
2. In the Service menu, select “System settings” and enter the system code.
(see also page 115).
After the correct system code is entered,
the following display appears:
In operating status, proceed as described
above until “Call barring” appears.
After the menu point “Call barring” is
selected, the following menu appears:
Select “Delete all” with OK.
All restricted numbers for all stations are
deleted at once.
The acknowledgment appears for 2 sec-
onds.
Delete All Barred Numbers
OK
Duration/Units
NEXT
Call barring
Sys cd/Mn sys cd
Call barring
Delete all
Delete all
OK
Lock Int0
NEXT
Lock Int1
Entry
deleted
115
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07B.FM
Operation with Comfort Mobile Unit System Settings
The following procedure is generally the first step to be taken in making most system settings.
After completing this procedure, select the desired system settings from the menu.
The Comfort mobile unit is in
idle status.
Push the F-key, the main menu appears:
Scroll through the main menu using NEXT...
until “Service” is on the 1st line,
and select “Service” with OK.
Scroll through the menu with NEXT ...
until “System settings” is on the 1st line,
and select “System settings” with OK .
Enter the 4-digit system code
if necessary, correct it with .
Complete the entry of the system code
by pushing OK.
After the correct system code is entered,
the following menu appears:
Additional steps are found in the corre-
sponding operating instructions.
First Steps for System Settings
a
TEL.BOOK
Station 2
REDIAL
ß
Telephone Book
Redial
OK
Telephone lock
NEXT
Service
- - - - - - - -
OK
Telephone book
NEXT
Service
System settings
o
Call forward. ON
OKNEXT
System settings
Cancel registr.
Enter
system code:
- - - -
OK
OK
Duration/Units
NEXT
Call barring
Sys cd/Mn sys cd
116
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07C.FM
Operation with Comfort Mobile Unit System Settings
You can stipulate which different types of devices are to be used at the different stations.
Cordless terminals can be mobile units or cordless connections such as Gigaset 1000TAE . For
these stations, “mobile unit” is pre-set.
For non-cordless devices, the device type “Telephone” is set. Modems or fax machines should
preferably be connected to station 0; a door interphone, however, can only be connected to sta-
tion 9.
1. In idle state, push the ßkey and select “Service” from the main menu.
2. In the Service menu, select “System settings” and enter the system code.
(see also page 115).
After the correct system code has been
entered, the following menu appears:
Scroll through the menu with NEXT ...
until “Equipment data” is in the 1st line;
then select with OK.
Scroll through the menu with NEXT...
until “a/b line” is in the 1st line; then select
with OK.
Set Non-cordless Station Lines (a/b lines):
Choose one of the two auxiliary devices,
using NEXT, and
select with OK ; here, “a/b line 0“.
The menu for the selection of the device
type appears (entire menu at left).
Using NEXT, choose a device type and stipu-
late it with SAVE; here, “FAX.
Neutral signifies fax and telephone.
Set Cordless Station Connections:
Scroll with NEXT ...
until, for example, “Internal 1” is in the first
line ; then select with OK.
The menu to select the type of equipment
appears (entire menu is at left).
Using NEXT, choose a device type and stipu-
late it with SAVE; here, “Fax”
(FAX applies here to a fax machine connec-
ted to a Gigaset 1000TAE).
Neutral signifies fax and telephone.
Set Connection Configuration for Internal Stations
Sys cd/Mn sys cd
OK
Call barring
NEXT
Duration/Units
Equipment data
a/b line
a/b line 0
Autom. seizure
Call pickup
OK
Access rights
NEXT
a/b line 0
a/b line 9
OK
Internal 1
NEXT
Active:Telephone
New
New
- - - - - - - -
New
New
:Modem
:Fax
:Neutral
:No funct.
New :Fax
:Neutral
New :No funct.
New
SAVE
NEXT
a/b line 0
a/b line 9
OK
Internal 1
NEXT
New
SAVE
NEXT
:FAX
New :Telephone
- - - - - - - -
Internal 1
Act. :Mobileset
New
- - - - - - - -
New
New
:Neutral
:Modem
:FAX
New :Telephone
117
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07C.FM
Operation with Comfort Mobile Unit System Settings
You can reset the base station to the initialization status, for example if you no longer have a clear
overview of your settings. In order to keep this as simple as possible, however, not all settings
are reset.
This procedure accomplishes the following:
1. In idle status, push the ßkey and select “Service” from the main menu.
2. In the Service menu, select “System settings” and enter the system code
(see also page 115).
After the corrected system code has been
entered, the following menu appears:
(Entire menu at left)
Scroll through the menu with NEXT ...
until “Initialisation” is on the 1st line; then
select with OK.
The setting is displayed for 2 seconds.
Resetting the Base Station to the Status at Initialization
a) Resets to
status at initialization:
b) Deletes: c) Unchanged:
System settings Units / Charges
Emergency numbers
Restricted numbers
System code
Registration of mobile units
Ring allocation
Connection/operation type
of the system
System cd/Mn sys cd
OK
Call barring
NEXT
Duration/Units
Initialisation
completed
Initialisation
118
Gigaset 1054, GBR: A30852-X954-B101-1-761928.10.96 1054K07C.FM
Operation with Comfort Mobile Unit System Settings
Using the ring allocation (allocation to telephone numbers), you can stipulate which mobile units
or auxiliary devices should be signalled when an external call comes in. The ring allocation is car-
ried out by entering the internal numbers in the list of the collective call group or group call list.
For stations which are designated to receive external calls, the COS “Incoming authorization” or
higher must be set (see „Set the COS for Internal Stations“ on page 113).
Up to 10 stations, of which 9 can be mobile units, can be entered in the lists for group call or call
diversion pickup.
Call waiting is signalled at stations engaged in an external or internal call
(see page 88).
Collective Call
At the time of initialization, collective call is set for all stations.
An incoming external call is signalled at all registered mobile units and auxiliary devices and
can be picked up by any mobile unit or auxiliary device.
By programming only one station into the collective call group, it is possible to have the calls
routed to one individual station.
Groups of stations which are part of the collective call
At the time of registration, the station is automatically placed in the collective call group. This
can be changed later.
Example:
External Allocated
telephone line internal station
1 1
2 2, 3, 4
Group Call with Call Diversion Pickup
An incoming external call is first signalled 3 times on the mobile units of the first call group
and can be picked up there. If no mobile unit in this group picks up the call, the second call
group is automatically signalled.
Example:
External Allocated internal stations Signal at
telephone line Group 1 Group 2 (after call diversion)
1 2, 3 6, 7 2, 3, 6, 7
2 1 4, 6 1, 4, 6
Ring Allocation for External Calls


Product specificaties

Merk: Siemens
Categorie: Vaste Telefonie
Model: gigaset 1054i

Heb je hulp nodig?

Als je hulp nodig hebt met Siemens gigaset 1054i stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Vaste Telefonie Siemens

Handleiding Vaste Telefonie

Nieuwste handleidingen voor Vaste Telefonie