General Description
The Shure Centraverse CVG is a professional gooseneck electret condenser
microphone for use in general installed sound reinforcement applications.
With dual gooseneck sections for full articulation, the CVG12/18 provides
scalable, best-in-class performance in a wide variety of locations, including
podiums and desktops.
Features
Cardioid polar pattern with tailored response for speech
Dual-section gooseneck enables ease of positioning and placement op-
tions
Three model variations with inline preamps: standard, mute switch, and
light ring indicator
Available in 12” (30.4 cm) and 18” (45.7 cm) gooseneck lengths
Commshield technology guards against unwanted RF interference from®
portable wireless devices (smartphones, etc.)
Included flange mount and snap-fit windscreen
Model Variations
Gooseneck Length
12: 12" gooseneck
18: 18" gooseneck
Mute Button and LED Indicator*
S: Includes mute button and bi-color LED on microphone body
RS: Includes mute button and On/Off colored indicator ring
*The Standard model does not feature a mute switch or LED
Color
B: Black
Polar Pattern
C: Cardioid
Note: Model availability depends on region. See your local Shure dealer or
distributor for details.
Installation
1. Drill a 22 mm (7/8 in.) hole in the mounting surface for the flange and three additional holes for the screws.
2. Screw the flange into place, and then set the microphone into the center hole.
3. Connect the microphone to a mixer or P.A. system using an XLR cable.
Note: This microphone requires +48V phantom power to operate.
22 mm
(7/8 in.)
Mute Button Operation
Press the button on the microphone body to turn the mute on/off. The standard
model does not feature a mute button.
1. CVG12S: Mute is indicated by an LED on the microphone body:
Green = Microphone is on
Red = Microphone is muted
2. CVG12RS: Mute is indicated by a light ring on the microphone head:
Red = Microphone is on
Off = Microphone is muted
1/4©2017 Shure Incorporated
CVG
Gooseneck Condenser Microphone
Guidelines For Use
1. Maintain a distance of approximately 15 - 30 cm (6 - 12 in.) between the sound source and the microphone.
2. Always use the supplied windscreen to control plosives and wind noise.
15 – 30 cm
(6 – 12 in.)
Specifications
Cartridge Type
Electret Condenser
Polar Pattern
Cardioid
Frequency Response
70 Hz to 16,000 Hz
Output Impedance
180 Ω
Sensitivity
open circuit voltage,at 1kHz,typical
-33 dBV/Pa[1](22 mV)
Maximum SPL[2]
1 kHz at 1% THD
120 dBSPL
Signal-to-Noise Ratio[3]
Ref. 94 dB SPLat 1kHz
67 dB
Shure IncorporatedCVG Gooseneck Condenser Microphone
2017/10/052/4
Dynamic Range
93 dB
Self Noise
equivalent SPL, A-weighted, typical
27 dBSPL
Preamplifier Output Clipping Level
at 1 kHz,at 1% THD
–7 dBV
Common Mode Rejection
10 Hz to 100 kHz
>45 dB
Polarity
Positive pressure on diaphragm produces positive voltage on pin 2 with respect to pin 3
Environmental Conditions
-18° to 57° C (0° to 135° F)Operating Temperature
-29° to 74° C (-20° to 165° F)Storage Temperature
0 to 95%Relative Humidity
Power Requirements
11–52 V DC[4],2.0 mACVGD
11–52 V DC[4],5.5 mACVGD/S
11–52 V DC[4],5.0 mACVGD/RS
Weight
1202 g (42.4 oz.)CVGD/12
1216 g (42.9 oz.)CVGD/18
0123
0[1] 1 Pa=94 dB SPL
1[2] THD of microphone preamplifier when applied input signal level is equivalent to cartridge output at specified SPL
2[3] S/N ratio is the difference between 94 dB SPL and equivalent SPL of self-noise, A-weighted
3[4]All specifications measured with a 48 Vdc phantom power supply. The microphone operates at lower voltages, but with slightly decreased headroom and
sensitivity.
Shure IncorporatedCVG Gooseneck Condenser Microphone
3/42017/10/05


Product specificaties

Merk: Shure
Categorie: Microfoon
Model: CVG18
Breedte: 15.09 mm
Diepte: 15.09 mm
Hoogte: 457 mm
Soort: Conferentiemicrofoon
Connectiviteitstechnologie: Bedraad
Montagewijze: Tafel
Microfoon mute: Ja
LED backlight: Ja
Ingangsspanning: 11 - 52 V
Aansluiting: XLR-3
Stroomverbruik: 2 mA
Verpakkingsinhoud: RPM640 Mounting Flange
Microphone direction type: Cardioïde
Gevoeligheid microfoon: -33 dB
Spreekspoel types: Condensor
Frequentie microfoon: 70 - 16000 Hz
XLR out: 1
Bedrijfstemperatuur (T-T): -18 - 57 °C
Maximaal geluidsdrukniveau (1 kHz): 120 dB
Output impedance: 180 Ohm
Microfoon Signal-to-Noise Ratio (SNR): 67 dB
Gevoeligheid (1 kHz): 22 mV/Pa
Microphone dynamic range: 93 dB
Eigenruis: 27 dB
Inclusief windscherm: Ja

Heb je hulp nodig?

Als je hulp nodig hebt met Shure CVG18 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Microfoon Shure

Handleiding Microfoon

Nieuwste handleidingen voor Microfoon

Elgato

Elgato Wave Neo Handleiding

11 September 2024
Røde

Røde XDM-100 Handleiding

6 September 2024
Røde

Røde PodMic USB Handleiding

6 September 2024
Valcom

Valcom V-400 Handleiding

5 September 2024
Valcom

Valcom V-9934 Handleiding

5 September 2024
Valcom

Valcom SBS-400 Handleiding

5 September 2024
Valcom

Valcom V-420 Handleiding

5 September 2024
Røde

Røde XCM-50 Handleiding

4 September 2024