OPERATION MANUAL
PORTABLE CO METER
2
Model:
pSENSE
pSENSE RH
INTRODUCTION
Features:
Triple displays of CO level, temp.
2
and humidity (pSENSE RH).
s
asy calibration
humidity
PC connect
Stable NDIR sensor for CO detection
2
Statistics of weighted average
TWA (8 hours weighted average)
STEL(15 minutes weighted average)
Backlight for working in dark area
Audile CO warning alarm
2
Battery and adaptor power supply
E manual on CO and
2
(RH for pSENSE RH only)
via RS232 interface
1
Thank you for purchasing this portable
CO meter. The me ter measures CO
2 2
level, air temp ., dew point, wet bulb temp .
and humi dity(DP, WB , RH are for model
pSENSE RH) and is an ideal instrume nt
for indoor air quality (IAQ) diagnosis.
Poor indoor air quality is considered
unhealthy because it causes tiredness,
loss of ability to concentrate, and even
illness(ex. Sick Building Syndrome ). IAQ
monitoring and survey, especially on CO
2
level and air ventilation become widely
applied in public areas such as offices,
classrooms, factories, hospitals and
hotels. It is also suggested in regulations
of industrial hygiene in some countries.
(Appendix)
The portable CO me ter uses NDIR (non-
2
dispersive infrared) technology to ensure
the reliability and long term stability. Its
useful in verifying HVAC system perform-
ance and air ventilation control.
MATERIAL SUPPLIED
Meter
4pcs AA batteries
Operation manual
Hard carrying case
This package contains:
Optional accessory:
Calibration kit 33% and 75% (00-0-0017)
RS232 cable and software
Adaptor (9V/100~240Vac)
(00-0-0018)
POWER SUPPLY
The meter is powered by either 4 AA
batteries or a DC adaptor(9V/1A output).
Install the batteries into the battery
compartment on the rear and make sure
they are in correct polarity and good
contact.
nd
Lob” will appear on the LCD .
And beeper sounds.
atter
When an adaptor is used, it will
cut off the power supply from batteries.
The adaptor cant be used as a battery
charger.
When battery voltage gets low, a
(Fig.1)
The CO sensor
2
cant work under low voltage, so it beeps
to indicate failed CO measurement
2
(press any key but to stop the beeps)
and the readings wont be displayed.
Please replace with fresh b ies or
connect with an adaptor.
%%