Sennheiser EW 352 G3 Handleiding

Sennheiser Receiver EW 352 G3

Lees hieronder de 📖 handleiding in het Nederlandse voor Sennheiser EW 352 G3 (42 pagina's) in de categorie Receiver. Deze handleiding was nuttig voor 45 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/42
300 Series
Instruction manual
Contents
1
Contents
Important safety instructions ............................................................................................................................................................. 2
System ............................................................................................................................................................................................... 2
Receiver .............................................................................................................................................................................................. 2
Bodypack transmitter and radio microphone ............................................................................................................................ 3
The ew 300 G3 evolution wireless series .......................................................................................................................................... 4
The frequency bank system ........................................................................................................................................................... 4
Product overview .................................................................................................................................................................................... 5
Overview of the EM 300 receiver .................................................................................................................................................. 5
Overview of the displays of the EM 300 receiver ...................................................................................................................... 6
Overview of the SK 300 bodypack transmitter ......................................................................................................................... 8
Overview of the displays of the SK 300 bodypack transmitter .............................................................................................. 9
Overview of the SKM 300 radio microphone ............................................................................................................................ 10
Overview of the displays of the SKM 300 radio microphone ................................................................................................ 11
Putting the devices into operation ................................................................................................................................................... 12
EM 300 receiver .............................................................................................................................................................................. 12
SK 300 bodypack transmitter ..................................................................................................................................................... 14
SKM 300 radio microphone .......................................................................................................................................................... 15
Using the devices .................................................................................................................................................................................. 17
Switching the devices on/off ....................................................................................................................................................... 18
Synchronizing a transmitter with the receiver ........................................................................................................................ 21
Deactivating the lock mode temporarily ................................................................................................................................... 21
Muting the audio signal or deactivating the RF signal ........................................................................................................... 22
Selecting a standard display ........................................................................................................................................................ 25
Overview of the operating menus .................................................................................................................................................... 25
Cleaning the devices ............................................................................................................................................................................. 29
Specifications ......................................................................................................................................................................................... 32
Manufacturer Declarations ................................................................................................................................................................. 36
For an animated instruction manual, visit the respective product pages at www.sennheiser.com.
There you will also find detailed instruction manuals for the individual devices.
Important safety instructions
2
Important safety instructions
System
Read this instruction manual.
Keep this instruction manual. Always include this instruction manual when passing the
devices and the mains unit on to third parties.
Heed all warnings and follow all instructions in this instruction manual.
Only clean the devices when they are not connected to the mains. Use a cloth for cleaning.
Only use attachments/accessories specified by Sennheiser.
Refer all servicing to qualified service personnel.
Servicing is required if the devices or the mains unit have been damaged in any way, liquid
has been spilled, objects have fallen inside, the devices have been exposed to rain or mois-
ture, do not operate properly or have been dropped.
WARNING: To reduce the risk of fire or electric shock, do not use the devices and the mains
unit near water and do not expose them to rain or moisture.
Receiver
Only use the supplied mains unit.
Unplug the mains unit from the wall socket
to completely disconnect the device from the mains,
during lightning storms or
when unused for long periods of time.
Only operate the mains unit from the type of power source specified in the chapter
“Specifications” (see page 32).
Ensure that the mains unit is
in a safe operating condition and easily accessible,
properly plugged into the wall socket,
only operated within the permissible temperature range,
not covered or exposed to direct sunlight for longer periods of time in order to prevent
heat accumulation (see “Specifications” on page 32).
Do not block any ventilation openings. Install the device in accordance with the instruc-
tions given in this instruction manual.
Do not install the device and the mains unit near any heat sources such as radiators, heat
registers, stoves, or other devices (including amplifiers) that produce heat.
Do not overload wall outlets and extension cables as this may result in fire and electric
shock.
Important safety instructions
3
Danger due to high volumes
This device is capable of producing sound pressure exceeding 85 dB(A). 85 dB(A) is the
sound pressure corresponding to the maximum permissible volume which is by law (in
some countries) allowed to affect your hearing for the duration of a working day. It is used
as a basis according to the specifications of industrial medicine. Higher volumes or longer
durations can damage your hearing. At higher volumes, the duration must be shortened in
order to prevent hearing damage. The following are sure signs that you have been
subjected to excessive noise for too long a time:
You can hear ringing or whistling sounds in your ears.
You have the impression (even for a short time only) that you can no longer hear high
notes.
Bodypack transmitter and radio microphone
Do not place the devices near any heat sources such as radiators, heat registers, stoves, or
other devices (including amplifiers) that produce heat.
Intended use of the system
Intended use of the ew 300 G3 series devices includes:
having read this instruction manual especially the chapter “Important safety instructions”,
using the devices within the operating conditions and limitations described in this instruc-
tion manual.
“Improper use” means using the devices other than as described in these instructions, or
under operating conditions which differ from those described herein.
The ew 300 G3 evolution wireless series
4
The ew 300 G3 evolution wireless series
With the ew 300 G3 evolution wireless series, Sennheiser offers high-quality state-of-the-art
RF transmission systems with a high level of operational reliability and ease of use. Transmit-
ters and receivers permit wireless transmission with studio-quality sound.
The frequency bank system
Please note: Frequency usage is different for each country. Your Sennheiser partner will have
all the necessary details on the available legal frequencies for your area.
The devices are available in 6 UHF frequency ranges with 1,680 frequencies per frequency
range:
Each frequency range (A–E, G) offers 26 frequency banks with up to 24 channels each:
Each of the channels in the frequency banks 1to 20has been factory-preset to a fixed
frequency (frequency preset). The factory-preset frequencies within one frequency bank are
intermodulation-free. These frequencies cannot be changed.
For an overview of the frequency presets, please refer to the supplied frequency information
sheet. Updated versions of the frequency information sheet can be downloaded from the
product page on our website at www.sennheiser.com.
The frequency banks U1to U6” allow you to freely select and store frequencies. It might
be that these frequencies are not intermodulation-free.
Range A: Range G:Range : Range B C: Range D: Range E:
516 558 566 608 626 668 734 – 776 780 822 823 – 865
Frequency bank 1... 20
Frequency bank U1 ... U6
Channel – frequency preset24
Channel frequency preset1
Channel frequency preset2
Channel – freely selectable frequency24
Channel freely selectable frequency1
Channel freely selectable frequency2
Product overview
7
Transmitter battery
status
Charge status:
When the battery charge status is critical, “LOW BATT
additionally appears on the display panel.
Lock mode icon Lock mode is activated
Display Meaning
approx. 100%
approx. 70%
approx. 30%
Battery icon is flashing; charge status is critical
Product overview
8
Overview of the SK 300 bodypack transmitter
Operating elements
Microphone/instrument input (MIC/LINE),
3.5 mm jack socket, lockable
MUTE switch
Socket for connection of RMS 1
external mute switch, 2.5 mm jack socket
Antenna
Operation and battery status indicator, red LED
(lit = ON/flashing = LOW BATTERY)
Audio overmodulation indicator, yellow LED
(lit = AF PEAK)
Charging contacts
SET button
 / rocker button (UP/DOWN)
Battery compartment
Battery compartment cover
Battery compartment catches
Infra-red interface
ON OFF/ button,
serves as the ESC (cancel) key in
the operating menu
Display panel, backlit in orange
Product overview
9
Overview of the displays of the SK 300 bodypack transmitter
After switch-on, the bodypack transmitter displays the standard display “Frequency/Name”.
For further illustrations and examples of the different standard displays, refer to page 25.
The display backlighting is automatically reduced after approx. 20 seconds.
Display Meaning
Audio levelAF Modulation of the bodypack transmitter with peak hold
function
When the transmitter’s audio input level is excessively high,
the “AF” display shows full deflection and, in addition, the
yellow AF PEAK LED lights up:
Frequency Current transmission frequency
Name Freely selectable name of the bodypack transmitter
Transmission icon RF signal is being transmitted
Lock mode icon Lock mode is activated
“ ”P (Pilot) Pilot tone transmission is activated
“ ”MUTE Microphone or line input is muted
Battery status Charge status:
MHz
543.200
ew300 G3
MUTE
P
AF
 
approx. 100%
approx. 70%
approx. 30%
Charge status is critical,
the red LOW BATT LED is flashing:
Product overview
10
Overview of the SKM 300 radio microphone
Operating elements
Microphone head (interchangeable)
Name and pick-up pattern of the
microphone head (not visible here)
MIC button
Body of radio microphone
Battery compartment (not visible from
outside)
Display panel, backlit in orange
Infra-red interface
Antenna
Color-coded protection ring;
available in different colors
Operation and battery status indicator,
red LED
(lit = ON/flashing = LOW BATTERY)
Charging contacts
Multi-function switch:
(DOWN), (UP) and (SET)
ON OFF/ button,
serves as the ESC (cancel) key in the
operating menu
Product overview
11
Overview of the displays of the SKM 300 radio microphone
After switch-on, the radio microphone displays the standard display Frequency/Name”.
For further illustrations and examples of the different standard displays, refer to page 25.
The display backlighting is automatically reduced after approx. 20 seconds.
Display Meaning
Audio levelAF Modulation of the radio microphone with peak hold
function
Frequency Current transmission frequency
Name Freely selectable name of the radio microphone
Transmission icon RF signal is being transmitted
Lock mode icon Lock mode is activated
P ” (Pilot) Pilot tone transmission is activated
MUTE Audio signal is muted
Battery status Charge status:
MHz
543.200
ew300 G3
MUTE
P
AF
 
approx. 100%
approx. 70%
approx. 30%
Charge status is critical,
the red LOW BATT LED is flashing:
Putting the devices into operation
12
Putting the devices into operation
EM 300 receiver
Setting up the receiver on a flat surface
Place the receiver on a flat, horizontal surface. Please note that the device feet can leave
stains on delicate surfaces.
Fitting the device feet Clean the base of the receiver where you want to fix the device feet.
Fit the device feet to the four corners of the receiver.
Mounting the rack
mount “ears”
To fasten the rack mount “ears:
Unscrew and remove the two recessed head screws (M4x8) on each side of the receiver
(see diagram).
Secure the rack mount “ears” to the sides of the receiver using the previously removed
recessed head screws.
Connecting the
rod antennas
The supplied rod antennas are suitable for use in good reception conditions.
Connect the antennas. You have the following options:
You can connect the rod antennas to the rear of the receiver.
You can use the optional AM 2 antenna front mount kit and mount the rod antennas
to the front of the receiver (see the instruction manual of the EM 300 receiver avail-
able on the ew G3 product page at www.sennheiser.com).
Align the antennas in a V-shape.
You can set up the receiver on a flat surface or mount it into a 19” rack. For informa-
tion on rack mounting, refer to the instruction manual of the EM 300 receiver
available on the ew G3 product page at www.sennheiser.com.
The rack mount “ears” are designed to help protect the operating elements from
damage or deformation, e.g. if the receiver is dropped. Therefore, fasten the
stacking elements, even if you do not want to rack mount your receivers.
When using more than one receiver, we recommend connecting remote antennas
and, if necessary, using Sennheiser antenna accessories. Fore more information, visit
the ew G3 product page at www.sennheiser.com.
Putting the devices into operation
15
Attaching and positioning the corresponding microphones
ME 2/ME 4 Use the microphone clip , to attach the microphone to clothing (e.g. tie, lapel).
The ME 2 clip-on microphone (shown on the right in the diagram) has an omni-directional
pick-up pattern. It is therefore not necessary to position it precisely.
Attach the ME 2 microphone as close as possible to the sound source.
The ME 4 clip-on microphone (shown on the left in the diagram) has a cardioid pick-up
pattern.
Position the ME 4 microphone so that its sound inlet is directed towards the sound source
(e.g. mouth).
ME 3 Adjust the ME 3 headmic so that a comfortable and secure fit is ensured.
The ME 3 headmic has a cardioid pick-up pattern.
Position the microphone so that its sound inlet is directed towards the sound source
(e.g. mouth).
Attaching the bodypack transmitter to clothing
You can use the belt clip ! to attach the bodypack transmitter to clothing (e.g. belt,
waist-and).
The belt clip is detachable so that you can also attach the transmitter with the antenna
pointing downwards. To do so, withdraw the belt clip ! from its fixing points and attach it
the other way round. The belt clip ! is secured so that it cannot slide out of its fixing points
accidentally.
To detach the belt clip:
Lift one side of the belt clip as shown in the diagram on the right-hand side.
Press down the belt clip at one fixing point and pull it out of the transmitter housing.
Repeat for the other side.
SKM 300 radio microphone
Inserting the batteries/accupack
For powering the radio microphone, you can either use two 1.5 V AA size batteries or the
rechargeable Sennheiser BA 2015 accupack.
!
CAUTION! Danger of damage to the radio microphone!
When unscrewing the radio microphone during operation while pressing the MIC button at
the same time, the latter can be damaged.
Do not press the MIC button while unscrewing the radio microphone.
Using the devices
18
Switching the devices on/off
EM 300 receiver
To switch the receiver on:
To switch the receiver to standby mode:
If necessary, deactivate the lock mode (see page 21).
To completely switch the receiver off:
Disconnect the receiver from the mains by unplugging the mains unit from the wall
socket.
SK 300 bodypack transmitter
To switch the bodypack transmitter on (online operation):
Push the two catches and open the battery compartment cover .
It is vital to observe the following notes:
Make sure that the desired frequencies are listed in the enclosed frequency
information sheet.
Make sure that the desired frequencies are approved and legal in your country
and, if necessary, apply for an operating license.
2
00
KM300
e
w300 G3
E
MHz
Briefly press the STANDBY button .
The receiver switches on and the Receiver Parameters standard display
appears.
Keep the STANDBY button pressed until OFF” appears on the display panel.
When in the operating menu, pressing the STANDBY button will cancel your entry
(ESC function) and return you to the current standard display.
Using the devices
19
To switch the bodypack transmitter off:
If necessary, deactivate the lock mode (see page 21).
To switch the bodypack transmitter (offlineon and to deactivate the RF signal on switch-on
operation):
To activate the RF signal:
Briefly press the ON/ .OFF button
The bodypack transmitter transmits an RF signal. The transmission icon is
displayed.
The red ON LED lights up and the standard display Frequency/Name
appears on the display panel.
You can switch the bodypack transmitter on and deactivate the RF signal on switch-
on. For more information, see below.
Press the ON/OFF button until OFFappears on the display panel. The red
ON LED goes off and the display panel turns off.
When in the operating menu, pressing the ON/OFF button will cancel your entry
(ESC function) and return you to the current standard display.
Press the ON/OFF button untilRF Mute On?” appears on the display panel.
Press the SET button .
The transmission frequency is displayed but the bodypack transmitter does not
transmit an RF signal. The transmission icon
is not displayed
. When
the pilot
tone function is activated on both bodypack transmitter and receiver
, RF Mute
appears on the receiver’s display panel.
Use this function to save battery power or to prepare a bodypack transmitter for use
during live operation without causing interference to existing transmission links.
Briefly press the ON/OFF button .
RF Mute Off” appears on the display panel.
Press the SET button .
The transmission icon is displayed again.
ON/OFF
ON/OFF
ON/OFF
SET
MHz
543.200
ew300 G3
MUTE
P
AF
ON/OFF
SET
Using the devices
20
SKM 300 radio microphone
To switch the radio microphone on (online operation):
To switch the radio microphone off:
If necessary, deactivate the lock mode (see page 21).
To switch the radio microphone on and to deactivate the RF signal on switch-on (offline
operation):
Briefly press the ON/OFF button .
The radio microphone transmits an RF signal. The transmission icon is
displayed.
The red ON LED lights up and the standard display Frequency/Name
appears on the display panel. The MIC button lights up red.
You can switch the radio microphone on and deactivate the RF signal on switch-on.
For more information, see below.
Press the ON OFF/ button until OFFappears on the display panel. The red
ON LED goes off. The MIC button goes off. The display panel turns off.
When in the operating menu, pressing the ON OFF / button cancel your entry (ESC
function) and return you to the current standard display.
Press the ON/OFF button until “RF Mute On?” appears on the display panel.
Press the multi-function switch .
The transmission frequency is displayed but the radio microphone does not
transmit an RF signal. The transmission icon is not displayed and the MIC
button does not light up. When the pilot tone function is activated on both radio
microphone and receiver, “RF Mute” appears on the receiver’s display panel.
Use this function to save battery power or to prepare a radio microphone for use
during live operation without causing interference to existing transmission links.
ON/OFF
ON/OFF
ON/OFF
MHz
543.200
ew300 G3
MUTE
P
AF
Using the devices
22
SK 300
SKM 300
How you are using the devices determines how long the lock mode remains deactivated:
Prior to this, the lock mode icon flashes, indicating that the lock mode is being activated.
Muting the audio signal or deactivating the RF signal
EM 300
To mute the audio signal:
To unmute the audio signal:
Press the jog dial.
The lock mode is temporarily deactivated (see below).
Press the rocker button.
Unlock?” appears on the display panel.
Press the SET button.
The lock mode is temporarily deactivated (see below).
Move the multi-function switch upwards/downwards.
Unlock?” appears on the display panel.
Press the multi-function switch.
The lock mode is temporarily deactivated (see below).
SET
When in the operating menu
The lock mode is deactivated as long as you are working with the operating menu.
When one of the standard displays is shown
The lock mode is automatically activated after 10 seconds.
When one of the standard displays is shown on the display panel, press the
STANDBY button.
RX Mute On?” appears on the display panel.
Press the jog dial.
The audio signal is muted. RX Muteappears in alternation with the current
standard display.
Press the STANDBY button.
RX Mute Off?” appears on the display panel.
Press the jog dial.
The muting is canceled.
Using the devices
23
SK 300
The MUTE switch allows you to mute the audio signal or to deactivate the RF signal. Via the
“ :Mute Mode” menu item, you can set the desired function of the MUTE switch
The “Push to muteand “Push to talk” menu items are only available in conjunction with the
RMS 1 external mute switch (optional accessory).
From the “Mute Mode” menu item, select the desired setting (see page 28).
Exit the operating menu.
Slide the MUTE switch to the left, to the position MUTE.
The bodypack transmitter reacts as indicated in the table.
The current state of the muting function or the RF signal is displayed on the display panel of
the bodypack transmitter. An additional display appears on the receiver’s display panel when
the pilot tone function is activated on both bodypack transmitter and receiver and, in
addition, this display has been activated via the Warnings menu item on the receiver
(see page 27).
Setting Slide the MUTE switch ... Function
“ ”Disabled ... to the left (position MUTE) None
“ ”RF On/Off ... to the left (position MUTE) Deactivates the RF signal
(offline operation)
... to the right Activates the RF signal
(online operation)
“ ”AF On/Off ... to the left (position MUTE) Mutes the audio signal
... to the right Unmutes the audio signal
Audio signal is muted
Transmitter’s display panel: MUTE is displayed
Receiver’s display panel: TX Mute” is displayed*
* only when activated on the receiver (see above)
Audio signal is activated (muting is deactivated)
Transmitter’s display panel: MUTE is not displayed
Receiver’s display panel: TX Mute” is not displayed
RF signal is deactivated
Transmitter’s display panel: Transmission icon is not displayed
Receiver’s display panel: RF Mute” is displayed*
*only when activated on the receiver (see above)
RF signal is activated
Transmitter’s display panel: Transmission icon is displayed
MHz
543.200
ew300 G3
MUTE
P
AF


Product specificaties

Merk: Sennheiser
Categorie: Receiver
Model: EW 352 G3
Kleur van het product: Black,Grey
Gebruikershandleiding: Ja
Bluetooth: Nee
Type aansluitplug: 3,5 mm
Connectiviteitstechnologie: Bedraad en draadloos
Garantiekaart: Nee
Hoofdtelefoonuitgangen: 2
HDMI: Nee
Equalizer-instellingen: Ja
Frequentiebereik: 80 - 18000 Hz
Lijnuitgang: Nee
Lijningang: Nee
Signaal/ruis-verhouding: 115 dB
Totale harmonische vervorming (THD): 0.9 procent
FM-band: 516 - 865 MHz
Afstandsbediening inbegrepen: Nee
Type batterij: AA

Heb je hulp nodig?

Als je hulp nodig hebt met Sennheiser EW 352 G3 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Receiver Sennheiser

Handleiding Receiver

Nieuwste handleidingen voor Receiver