RS8711ETC 1/2
Operation Instruction
一
一
一
一一, Main Functions:
1. Radio-controlled function
2. weather forecast for 4 states: sunny, semi-sunny, cloudy, rainy
3. seven languages to show the day: English, Germany, French, Italian, Spanish, Dutch, Danish
4. indoor temperature range: 0℃--50℃, sampling cycle: 12 seconds
℃--50℃, sampling cycle: 12 seconds
℃--50℃, sampling cycle: 12 seconds
℃--50℃, sampling cycle: 12 seconds℃--50℃, sampling cycle: 12 seconds
5. indoor humidity range: 20%-----95%
6. outdoor temperature with RF: up to 3 channels
7. in/out trend indication of temperature
8. indication of the comfort index
9. the function of Alarm/ Snooze
10. 12/24 hour selectable
11. moon phase
12. LED light
13. world time zone set, -12/+12 hours
二. Power-On and reset
1. When Power-On and reset, LCD full display for 3 seconds
enter the normal state after “Beep”
check temperature and humidity
2. The calendar defaults 0:00 January 1, 2004
3. Alarm defaults 0:00
4. The weather icon defaults semi-sunny
5. Temperature scales defaults Celius degree ℃
℃
℃
℃℃. Time system defaults 24Hr.
三
三
三
三三. instruction of operating the KEYS
3.1 Key functions
Six functional keys: Set, Alarm, Up, Down, Snooze, Channel
Clock Alarm Up Down SNZ/LIGHT Channel Alert Max/Min
standard mode
Click ----- Alarm
on/off
12hr/24hr
switchable
° °C/ F
switchable
Back Light/
enter Snooze
Switch to
CH1,CH2,CH3
On/Off
temperature
Alarm
Switchable
between
CH1, 2, 3
Hold enter into
clock setting
enter into
alarm setting
----- ----- ----- Clear
current
registered
Into
temperature
alarm setup
clear max/
min
Time set
Click Confirm the
setting item
----- one step
forward
one step
backward
----- --------- ---------- ----------
Hold ----------- ----- 8steps/second
forward
8steps/second
backward
----- --------- ----------- ----------
Alarm set
Click ---------- confirm the
setting item
one step
forward
One step
backward
----- --------- ------------ --------
Hold ---------- ----- 8steps/second
forward
8steps/second
backward
----- --------- ------------ -----
Temp alert set
Click
-----------
-----
one step
forward
one step
backward
-----
Choose
needed
channel
Confirm the
Setting item
---------
Hold
----------
------
8steps/second
forward
8steps/second
backward
-----
------
------
----------
3.2 Normal states
1. hold “clock” for 2 seconds to enter into time setting
2. click “Alarm” to switch the alarm on/off
3. hold “Alarm ” for 2 seconds to enter into Alarm setting
4. click “Up” to switch between 12hr/24hr
5. press “Down” to switch between °C/°F
6. press”SNZ/LIGHT”to turn on the back light 5 second
7. when ALARM rings, click “SNZ/LIGHT” to enter into the snooze state every 5 minutes
8. press “Channel” to switch RF channel, CH1
CH2 CH3
9. hold “Channel” key for 2 seconds to clear out all data of current “Channel”
10. press”ALERT”key to switch temperature alarm on/off
11. hold”ALERT”key 2 seconds to enter temperature alarm setting
12. press”MAX/MIN”key to check maximal and minimum of temperature and humidity
13. hold”MAX/MIN”key 2 seconds to clear all record of temperature and humidity
3.3 Time set
1. hold “clock” key for 2 seconds to enter into time setting
2. the sequence of time setting: Year(2000-2050)
Month
Date
Language
Hour
Minute
Time zone
Exit
Function
Operation
RS8711ETC 2/2
3. there will have 1Hz flashing during setting
4. press “clock” to confirm the setting, and enter the next setting state
5. press “Up” one time, the setting will go ahead for one step; hold the key for 2 seconds, it will run forward by 8 steps/second.
6. press “Down” one time, the setting will backward for one step; hold for 2 seconds, it will run back by 8 steps/second.
7. moon phase is changed accordingly time changed.
8. the system will exit automatically if no key is operated in 8 seconds.
3.4 Alarm set
1. hold “Alarm” key for 2 second to enter into alarm setting
2. the sequence of alarm setting: Hour
Minute
exit
3. there will have 1Hz flashing during setting
4. press “Alarm” to confirm the setting, and enter the next setting state
5. press “Up” one time, the setting will go ahead for one step; hold the keys for 2 seconds, it will run forward by 8 steps/seconds.
6. press “Down” one time, the setting will backward for one step; hold for 2 seconds, it will run back by 8 steps/second.
7. the system will exit automatically if no key is operated in 8 seconds.
3.5 Temperature alarm setting
1. hold”ALERT”2 second into ALERT setting
2. setting sequence :upper limited
lower limit
exit
3. press”CHANNEL”key when setting upper limited and lower limited to change different channel.
4. default of upper limited is:+70°C ,lower limited is -50°C
5. there will have 1Hz flashing during setting
6. press”ALERT”key confirm the end of setting then enter next item setting
7. press “Up” one time, the setting will go ahead for one step; hold the keys for 2 seconds, it will run forward by 8 steps/seconds.
8. press “Down” one time, the setting will backward for one step; hold for 2 seconds, it will run back by 8 steps/second.
9. the system will exit automatically if no key is operated in 8 seconds.
10. Alert will automatically turn on when setting is finish.
3.6 RCC receiving function:
1. How to enter RCC receiving status:
a. It will enter RCC receiving state automatically 3 minutes after powering ON or resetting.
b. It enters RCC receiving automatically at2:00, 3:00, 4:00, 5:00 everyday.
c. Press “Down” or “UP” key for 2 seconds to enter RCC receiving status forcibly.
2. RCC receiving time is 7 minutes.
3. When it is receiving signals, press “Down” or “UP” key will exit RCC receiving status, pressing any other key will have no effect.
4. When DST is able and is receiving the signal, it will display the symbol of sun on the LCD, showing that it enters the DST system, and the
time will be 1 hour faster.
5. When the RCC symbols display fully, the relative RCC icon will be OFF if the present time is changed.
四
四
四
四四. Function and effect
4.1 The receiving function of RF
1. after installing the battery and checking temperature/humidity, it will enter RF receiving state automatically for 3 minutes.
2. under normal display mode, hold the “Channel” key for 2 seconds to clear out the channel information
3. if there is no effective signal with same ID code received for the current channel in 35 minutes, the temperature of that CH will shows “--.-“.
4. the temperature display will resume back when the correct signal is received again
4.2 The function of alarm
1. the BUZZER will ring for 2 seconds as below:
a. 0 – 10 sec.: one “beep” per second
b. 10 – 20 sec.: two “beep” per second
c. 20 – 30 sec.: four “beep” per second
d. after 30 sec.: “beep” continuously
2. when ringing, click “SNZ/LIGHT” key once to enter into 5 minutes snooze states, exit if any other key is clicked.
4.3 The function of temperature and humidity
1. the indoor temperature display range: 0℃
℃
℃
℃℃ -- +50℃
℃
℃
℃℃ (32F -- +122F)
2. the indoor temperature proposed operating range: 0℃
℃
℃
℃℃ -- +40℃
℃
℃
℃℃ (32F -- +104F)
3. the outdoor temperature display range: - 50℃
℃
℃
℃℃ -- +70℃
℃
℃
℃℃ (-58F -- +158F)
4. the outdoor temperature proposed operating range: -5℃
℃
℃
℃℃ -- +45℃
℃
℃
℃℃ (23F -- +113F)
5. the temperature resolution: 0.1℃
℃
℃
℃℃
6. the indoor humidity range: 20% --- 95%
7. the humidity resolution: 1%RH
8. sampling period: 12 seconds.
9. the temperature and hygrometer sampling will be held when the alarm is ringing
10. the RF Transmission Frequency: 433.92MHz
11. No. of Remote unit: Up to 3units
4.4 The function of weather forecast
1. weather icons for 4 states: sunny
semi-sunny
cloudy
rainy
Product specificaties
Merk: | Sencor |
Categorie: | Weerstation |
Model: | SWS 30 |
Heb je hulp nodig?
Als je hulp nodig hebt met Sencor SWS 30 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Weerstation Sencor
1 December 2024
3 Juli 2024
2 Juli 2024
2 Juli 2024
2 Juli 2024
2 Juli 2024
2 Juli 2024
2 Juli 2024
2 Juli 2024
25 November 2023
Handleiding Weerstation
- Weerstation Braun
- Weerstation Daewoo
- Weerstation Honeywell
- Weerstation Ade
- Weerstation Adler
- Weerstation Alecto
- Weerstation Ascot
- Weerstation Auriol
- Weerstation Balance
- Weerstation Balance Meteo
- Weerstation Beurer
- Weerstation Blaupunkt
- Weerstation Brandson
- Weerstation Bresser
- Weerstation Brigmton
- Weerstation Daikin
- Weerstation Davis
- Weerstation Denver
- Weerstation Dexford
- Weerstation Digi-tech
- Weerstation DMV Electronics
- Weerstation Durabase
- Weerstation Ea2 LABS
- Weerstation Elgato
- Weerstation Elro
- Weerstation ELV
- Weerstation EQ-3
- Weerstation Eurochron
- Weerstation Extech
- Weerstation Fluke
- Weerstation Garni
- Weerstation Gira
- Weerstation GlobalTronics
- Weerstation Guardo
- Weerstation Hama
- Weerstation Hesdo
- Weerstation HomeMatic
- Weerstation Hyundai
- Weerstation Inovalley
- Weerstation Irox
- Weerstation IT
- Weerstation Konig
- Weerstation Krontaler
- Weerstation La Crosse
- Weerstation Lexibook
- Weerstation Livoo
- Weerstation Lowrance
- Weerstation Marquant
- Weerstation Meade
- Weerstation Mebus
- Weerstation Medisana
- Weerstation Minox
- Weerstation Muse
- Weerstation Nasa
- Weerstation National Geographic
- Weerstation Nedis
- Weerstation Netatmo
- Weerstation Nor-tec
- Weerstation Paget Trading
- Weerstation PCE Instruments
- Weerstation Perel
- Weerstation Prestigio
- Weerstation Profile
- Weerstation Pyle
- Weerstation Renkforce
- Weerstation Rocktrail
- Weerstation Saphir
- Weerstation Saxon
- Weerstation Sempre
- Weerstation Soehnle
- Weerstation Solar
- Weerstation Steinberg
- Weerstation Tanita
- Weerstation Taylor
- Weerstation Techno Line
- Weerstation Technoline
- Weerstation Telefunken
- Weerstation TFA
- Weerstation Theben
- Weerstation Thierry Mugler
- Weerstation Thomson
- Weerstation Unitec
- Weerstation UPM
- Weerstation Velleman
- Weerstation Ventus
- Weerstation Vitek
- Weerstation Weinberger
- Weerstation Xeecom ApS
- Weerstation Ytora
- Weerstation Jacob Jensen
- Weerstation Jung
- Weerstation Optex
- Weerstation Oregon Scientific
- Weerstation Orion
- Weerstation Otio
- Weerstation Clas Ohlson
- Weerstation Camry
- Weerstation Clatronic
- Weerstation ECG
- Weerstation OBH Nordica
- Weerstation GoGEN
- Weerstation Goddess
- Weerstation EMOS
- Weerstation Cotech
- Weerstation Levenhuk
- Weerstation Cresta
- Weerstation Avidsen
- Weerstation Majestic
- Weerstation Prologue
- Weerstation Trevi
- Weerstation Day
- Weerstation Kemot
- Weerstation Chacon
- Weerstation AcuRite
- Weerstation Buienradar
- Weerstation La Crosse Technology
- Weerstation EVE
- Weerstation Waldbeck
- Weerstation EQ3
- Weerstation Homematic IP
- Weerstation EMOS SELECT
- Weerstation Uzoli
- Weerstation TFA Dostmann
- Weerstation Greisinger
- Weerstation Ease Electronicz
- Weerstation Rebel
- Weerstation PeakTech
- Weerstation YONO
- Weerstation JDC
- Weerstation Greenure
- Weerstation Chauvin Arnoux
- Weerstation ChiliTec
- Weerstation Global Water
- Weerstation Marathon
- Weerstation Gewiss
- Weerstation Browin
- Weerstation ClimeMET
- Weerstation Baldr
- Weerstation Setti+
- Weerstation Bearware
Nieuwste handleidingen voor Weerstation
15 December 2024
15 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024