Seiko S05A Handleiding

Seiko Horloge S05A

Lees hieronder de πŸ“– handleiding in het Nederlandse voor Seiko S05A (5 pagina's) in de categorie Horloge. Deze handleiding was nuttig voor 41 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/5
NOTES ON THE BATTERY
●Do not remove the battery from the stopwatch.
●If it is necessary to take out the battery, keep it out of the reach of children. If a child swallows it, consult a doctor
immediately.
●Never short-circuit, heat or otherwise tamper with the battery, and never expose it to fire. The battery may burst,
become very hot or catch fire.
●The battery is not rechargeable. Never attempt to recharge it, as this may cause battery leakage or damage to the
battery.
WARNING
NOTES ON THE STRAP
●The stopwatch has a strap for wearing it around your neck. Take good care lest it should be caught by something
near you or wind around your neck.
●Please also note that the strap may damage your clothes, or injure your hands, neck or other parts of your body.
You are now the proud owner of a SEIKO Digital Stopwatch Cal. S05A. For best results, please read the instructions in
this booklet carefully before using your SEIKO Digital Stopwatch. Please keep this manual handy for ready reference.
TO PRESERVE THE QUALITY OF YOUR STOPWATCH
●WATER RESISTANCE (5 bar)
Your stopwatch is designed and manufactured to
withstand up to 5 bar, such as accidental contact with
splashes of water or rain.
Do not operate the buttons when the stopwatch is wet or
in water.
●TEMPERATURES
If the stopwatch is left in direct sunlight for a long time,
the display may become black, but this condition will be
corrected when the stopwatch return s to n ormal
temperature.
Do not leave your stopwatch in very low temperatures
below -10ΒΊC (+14ΒΊF) for a long time since the cold may
cause:
a. a slight time loss or gain.
b. the change of digits to become slow.
c. the display light to dim.
However, the above conditions will be corrected when
the stopwatch returns to normal temperature.
●SHOCKS
Do not subject it to violent shocks.
●MAGNETISM
Your stopwatch will not be affected by magnetism.
●CHEMICALS
Be careful not to expose the stopwatch to solvents,
mercury, cosmetic spray, detergents, adhesives or paints.
Otherwise, the case, etc. may become discolored,
deteriorated or damaged.
●PERIODIC CHECK
It is recommended that the stopwatch be checked once
every 2 to 3 years. Have your stopwatch checked by an
AUTHORIZED SEIKO DEALER or SERVICE CENTER to
ensure that the case, buttons, gasket and crystal seal
remain intact.
●PRECAUTION REGARDING CASE BACK PROTECTIVE FILM
If your stopwatch has a protective film and/or a sticker on
the case back, be sure to peel them off before using it.
●STATIC ELECTRICITY
The IC (Integrated Circuit) used in your stopwatch will be
affected by static electricity which may disturb the display.
Keep your stopwatch away from close contact with objects
such as TV screens which emit strong static electricity.
●LIQUID CRYSTAL PANEL
The normal life expectancy for a liquid crystal panel is
approximately 7 years. After that it may decrease in
contrast, becoming difficult to read. Please contact your
AUTHORIZED SEIKO DEALER or SERVICE CENTER if you
wish to have a new panel fitted (guaranteed one year).
FEATURES
The SEIKO Quartz Stopwatch for industrial measurement Cal. S05A is a digital decimal stopwatch that can be used for activities such as production
control and performance analysis. The stopwatch features a lap time/split time memory function that can store and recall up to 100 sets of lap
times and split times. Time/calendar, timer, and alarm functions are also provided.
β– STOPWATCH
The stopwatch can measure up to 99999.9 DM (999.999 minutes) in 1/10 DM(1/1000
minute) increments.
*DM (Decimal): Unit used in a decimal system
1 DM=1/100 minute
100 DM = 1 minute
600 DM = 6 minutes
6000 DM = 60 minutes
β– LAP TIME, LAP TIME IN PROGRESS AND SPLIT TIME DISPLAYS
Three separate stopwatch displays are available for lap time, lap time in progress and
split time measurements.
β– MEMORY FUNCTION
Up to 100 lap/split time data can be stored in memory, and they can be recalled either
during or after the measurement.
β– TIME/CALENDAR
Year, month, day, date, hour, minutes and seconds are displayed.
The calendar automatically adjusts for odd and even months including February of leap
years from January 1, 2006 to December 31, 2055.
β– AUTOMATIC SHUT-OFF FUNCTION
When the stopwatch is left untouched for one hour, the display automatically becomes
blank in order to minimize battery consumption.
β– DOUBLE REPEAT TIMER
β€’ The built-in two descending timers (which allow you to set two different timer times)
can be used repeatedly one after the other.
β€’ Each Timer 1 and Timer 2 can be set for any desired amount of time from 10 seconds
up to 99 hours, 59 minutes and 59 seconds in one-second increments.
β€’ For easy distinction between Timer 1 and Timer 2, the time-up warning beeps are
different in tones.
R
E
C
A
L
L
R
E
C
A
L
L
MEMORY
MEMORY
MEMORY
MEMORYMEMORY
100
100
100
100100
D E C I M A L
S
T
A
R
E
T
/
S
T
O
P
L
A
P
/
S
P
L
I
T
R
E
S
E
T
INDUSTRIAL STOP WATCH
A
B
C
D
DISPLAY AND BUTTONS
SEIKO DIGITAL STOPWATCH FOR INDUSTRIAL MEASUREMENT Cal. S05A
CHANGE OF DISPLAYS
TIME/CALENDAR
display
STOPWATCH
<LAP TIME> display
STOPWATCH
<LAP TIME IN PROGRESS>display
ALARM display STOPWATCH
<SPLIT TIME> display
TIMER display
Press Button D to change the display mode.
D
DD
D
D
D
β– ALARM
β€’ The daily alarm sounds once at the designated time (hour, minute) every 24 hours.
β– BATTERY LIFE INDICATOR
* If Buttons A, B, C and D are pressed at the same time, all the data in memory will be erased. Refer to β€œHOW TO RESET THE BUILT-IN IC” on page 13 for further details.
TIME/CALENDAR SETTING
B
AC
β€œA” (AM)/
β€œP” (PM)
mark Hour
Year
Month
D
Date
Day
Seconds
Minutes
Press to show the TIME/CALENDAR display.
β–Ό
D
BPress and hold for 2 seconds to show the TIME/CALENDAR SETTING display.
β–Ό
C
A
β–Ό
Press repeatedly to select the digits (flashing) to be adjusted.
MINUTES HOUR DATE(DAY)
YEAR
12-/24-HOUR INDICATION
SECONDS
β–Ό
β–Ό
β–Ό
β–Ό
β–Ό
β–Ό
β–Ό
Press to set the flashing digits or reset the SECONDS to β€œ00.”
* The DAY disappears and the SECOND digits start flashing.
* The digits move quickly if Button A is kept pressed.
●12-/24-hour indication setting:
Change between 12- and 24-hour indications is made alternately with each press of Button A.
●Automatic shut-off function setting (ECO) :
With each press of Button A, the automatic shut-off function(ECO) is alternately set to "ON" and
"OFF."
B
β–Ό
After all the adjustments are completed, press to return to the TIME/CALENDAR
display.
●
The DAY is automatically set once the YEAR, MONTH and DATE are set.
●
To quit the time/calendar setting, press Button B. When the stopwatch is left untouched, it automatically returns to the TIME/CALENDAR display within two
to three minutes.
●
The calendar adjusts automatically for odd and even months including February of leap years from January 1, 2006 to December 31, 2055.
●
When setting the HOUR digits in the 12-hour indication, check that β€œA” (AM)/β€œP” (PM) mark is correctly set. In the 24-hour indication, no mark is displayed.
●
If Button A and C are pressed simultaneously, all the digital segments light up. This is not a malfunction. Press any of Button A, B, C or D to return to the TIME/
CALENDAR display.
MONTH
β–Ό
AUTOMATIC SHUT-OFF
(ECO)
* With each press of Button C in TIME/CALENDAR
display, the confirmation sound for button
operation is alternately switched "ON" and "OFF."
While the confirmation sound for button operation
is set to "ON," the mark appears on display.
Confirmation sound
for button operation
STOPWATCH
●The stopwatch can measure up to 99999.9 DM in 1/10 DM increments.
●Three separate measurement displays are available; lap time, lap time in progress and split time displays.
[LAP TIME IN PROGRESS display][LAP TIME display]
AC
B
D
β€œLAP” mark Lap No.
Lap time
Accumulated
elapsed time
AC
B
D
β€œRLP” mark Lap No.
Lap time
AC
B
D
β€œSPL” mark Split No.
Accumulated
elapsed time
Split time
Lap time
in progress
[SPLIT TIME display]
A C
B
STOPWATCH OPERATION
1 Standard measurement
D
C AC
START STOP RESET
β–Ό
β–Ό
D
2 Accumulated elapsed time measurement
Press to show the LAP TIME, LAP TIME IN PROGRESS or SPLIT TIME display.
D
C CC
START STOP RESTART
C
STOP
A
RESET
β–Ό
β–Ό
β–Ό
β–Ό
3 Lap time measurement
Press to show the LAP TIME or LAP TIME IN PROGRESS display.
D
* Restarting and stopping the stopwatch can be repeated by pressing Button C.
A AC
START LAP 1 LAP 2
C
FINISH
A
RESET
β–Ό
β–Ό
β–Ό
β–Ό
* Lap time measurement can be repeated by pressing Button A.
Split time
Lap time
Start
* β€œLap time” is the time that has elapsed from the start of
one stage of an activity to that of the next stage.
β€œSplit time” is the time that has elapsed from the start of
an activity to any given stage.
●
In the LAP TIME display, the previous lap time is displayed in the upper row
while the accumulated elapsed time is displayed in the lower row during
measurement.
●
In the LAP TIME IN PROGRESS display, the previous lap time is displayed
in the upper row while the current lap time measurement is displayed in
the lower row during measurement.
Lap No. for the previous lap
Lap time for the previous lap
Accumulated elapsed time
Lap time in progress
Lap No. for the previous lap
Lap time for the previous lap
4 Split time measurement
A AC
START SPLIT 1 SPLIT 2
C
FINISH
A
RESET
β–Ό
β–Ό
β–Ό
β–Ό
* Split time measurement can be repeated by pressing Button A.
D
AC
Lap time
Split time
Lap/split No.
Flashing mark appears
while the measurement is in progress.
●
If no lap time/split time measurement is made in the STOPWATCH display and no data is stored in memory, the display
shown at right will appear when the display is changed over to the MEMORY RECALL.
●
Even if the stopwatch is reset to β€œ00,” stored data is not erased and can be recalled unless a new measurement is started.
●
The stopwatch can measure the lap time/split times as many times as necessary, but only the first 100 data will be stored
in memory.
5 How to use the memory function
●Up to 100 lap/split time data can be stored and recalled either during or after measurement.
Press to show the MEMORY RECALL display.
B
* In memory recall after measurement, the oldest measurement stored in memory is displayed first.
In memory recall during measurement, the newest one is displayed first.
β–Ό
CWith each press, the stored data is recalled successively from the oldest to the
newest.
AWith each press, the stored data is recalled successively from the newest to the
oldest.
or
β–Ό
Press to return to the STOPWATCH display.
B
Press to show the SPLIT TIME display.
D
●Before using the stopwatch, be sure to reset the digits to β€œ00.”
When the stopwatch is stopped, press Button A.
When it is counting, press Button C to stop the measurement and then press Button A.
Press to show the LAP TIME, LAP TIME IN PROGRESS or SPLIT TIME display.


Product specificaties

Merk: Seiko
Categorie: Horloge
Model: S05A

Heb je hulp nodig?

Als je hulp nodig hebt met Seiko S05A stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Horloge Seiko

Seiko

Seiko 6N76 Handleiding

27 Augustus 2024
Seiko

Seiko 6N53 Handleiding

27 Augustus 2024
Seiko

Seiko 6N52 Handleiding

27 Augustus 2024
Seiko

Seiko 6G28 Handleiding

27 Augustus 2024
Seiko

Seiko 4N30 Handleiding

27 Augustus 2024
Seiko

Seiko 4227 Handleiding

27 Augustus 2024
Seiko

Seiko 6N32 Handleiding

27 Augustus 2024
Seiko

Seiko 6N42 Handleiding

27 Augustus 2024
Seiko

Seiko 6N22 Handleiding

27 Augustus 2024
Seiko

Seiko 1N01 Handleiding

27 Augustus 2024

Handleiding Horloge

Nieuwste handleidingen voor Horloge