SecuTech SECU-TANK ONE Handleiding

SecuTech Meetapparatuur SECU-TANK ONE

Lees hieronder de 📖 handleiding in het Nederlandse voor SecuTech SECU-TANK ONE (16 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 27 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
Version 04-2017
Setup and Operation
P. 1
Setup and Operation
of SECU-TANK tank monitoring devices ’ ’
ONE RELAY / software version V6.0x or higher
QUATTRO software version V6.0x or higher
NET / QUATTRO NET software version V6. or higher0x
DATA GSM / QUATTRO GSM software version V6.0x or higher
Content:
Page:
P. 2
Setup and Operation
Version 04-2017
Device setup and probe mounting
Concerning installation and mounting as well as regulations and operation please check the cor-
responding device documentation.
The initial setup is to be performed after completed mounting.
The monitoring devices of the SECU TANK-series are to be used for tank content measurement
and if applicable for data forwarding or transmission.
For programming of the device the subsequent description is to be followed.
Determine the tank data beforehand and enter it in the menu input steps.
To enter the menu mode from the display g mode press the [Enter] push button. in
Conrm the ‘Exit’ menu item in step 0 or 7 or 8 to exit the programming mode and return to the
general displaying mode.
This tank content meas ing system is not a safety device. ur
The device can support the safety device of the tank but cannot replace it.
Control elements and display
Pushbuttons
The device setting is to be performed via three little blue pushbuttons: [ + ] [Enter] [ - ]
They are located on the electronic PCB between the connecting clamps.
Language
The menu operating language is selectable via menu item 18 by pressing the buttons
[Enter] [ + ] [ + ] [ + ] . . . 18. Language/Sprache [Enter] . . .
The setup of the device has to be completed once during the initial setup. After the initial setup
the device operates in the displaying mode with closed cover.
Display panel
The LCD-display consists of 2 rows of 16 characters.
The display has a background lighting for the best readability at all lighting conditions.
Depending on the number of connected measuring the following display will be shown probes :
One tank: Two or more tanks , paging forward… :
In case of more than one tank the displaying of the single tanks shown above can be exten ded
by showing the total inventory the percent values of the single tanks. and
At menue item ‘6. View’ select ‘Percent = YES ( / No)
(paging forward to)
Tank 2: => ...
T2 Nam Content/Le
Fillspace/L cm/%
T1 Name Content/L
Fillspace/L cm/%
Total invent. Liters∑
% values: T1 T2 T3 T4
Liters T1 Liters T2
Liters T3 Liters T4
Version 04-2017
Setup and Operation
P. 3
Choose the displaying mode:
In m View the favored displaying mode has to be selected. en ep u st ‘6. ‘
Therefore the menu steps 1 to 5b need to be setup.
The upper display line shows the name of the tank/uid.
The tank can be renamed in ’18. Language+Name‘.
The lower display line can show the llable free space in the tank and /or the inventory volume in
percent up to the lling limiter or the present cm level.
Setup: View tanks ‘Single/Details’
In line 2: Fillable spac (-) L + Vol. percent: e
(bottom left) (bottom right)
In line 2: Fillable space (-) L + Level in cm:
In line 2: Volume percent + Level in cm:
RECOMMENDATION:
Choose displaying of llable space + % or cm.
In case of tank lling the person has to determine the llable free space in the tank
before start fueling.
Another benet:
In the ic above the left value in the lower line shows graph –x.xxxL
That the llable free space as well as the consumed amount since last time is
the tank has been fueled up to the lling limit.
ALTERNATIVE In case of a QUATTRO-xxx device
with 2 or 3 or 4 measuring probes tanks in example (3 )
the displaying may be setup to ‘common/together . ‘
(Shows only the Liter values, without paging forward.)
Additionally the total inventory can be display , ∑ed
showing the Liter sum and the single % values of
each tank: Select ‘Percent values = YES’


Product specificaties

Merk: SecuTech
Categorie: Meetapparatuur
Model: SECU-TANK ONE

Heb je hulp nodig?

Als je hulp nodig hebt met SecuTech SECU-TANK ONE stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Meetapparatuur SecuTech

Handleiding Meetapparatuur

Nieuwste handleidingen voor Meetapparatuur