SchwankAir MonsterFans MF-ST09-WH Handleiding

SchwankAir Ventilator MonsterFans MF-ST09-WH

Lees hieronder de 📖 handleiding in het Nederlandse voor SchwankAir MonsterFans MF-ST09-WH (12 pagina's) in de categorie Ventilator. Deze handleiding was nuttig voor 8 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
schwankgroup.com/monsterfans
MonsterFans Style Series
Installation Manual
2schwankgroup.com/monsterfans
Table Of Contents
Overview ..............................................................................................................................................3
Components .................................................................................................................................3
Technical Data ....................................................................................................................................4
Fusing and Thermal Limiting ...............................................................................................................5
Fuses...............................................................................................................................................5
Thermal Limiting ............................................................................................................................5
Safety ....................................................................................................................................................6
Clearances ...................................................................................................................................
Installation Preparation.......................................................................................................................7
Preparation ...................................................................................................................................7
Tools Required ..............................................................................................................................7
Items Included ..............................................................................................................................7
Hardware Included ......................................................................................................................7
Installation Procedure .........................................................................................................................9
Installation of the Mounting Hardware .....................................................................................12
Installing the Blades ....................................................................................................................14
Installing the LED Light Kit................. ...........................................................................................15
Installing the Hub Cover [with Lens] ..........................................................................................16
Electrical Installation ..........................................................................................................................18
HMI Control .........................................................................................................................................19
HMI/CAT 5 Cable Connection ..................................................................................................19
Maintenance ......................................................................................................................................20
Recommended Maintenance Schedule ................................................................................21
4schwankgroup.com/monsterfans
Technical Data
Conformity CE Low Voltage [2006/95/EC] & EMC [2004/108/EC]
Directives
EN61000-6-2:2005, EN61000-6-4:2007
IEC 60335-2-80:2015 IEC 60335-1:2015
Approvals UL61800-5-1
CSA C22.2 No113
Input Voltage Phase
Imbalance
≤2%
Input Voltage 110-240 VAC
Input Current 4.6 @ 120VAC, 2.5A @ 240VAC
Input Frequency 50-60Hz
Supported Power Systems TT TN For central ground systems, operation is permitted
without restrictions.
Humidity ≤ 95% Non-condensing
Temperature Range Transport -40°F…+160°F [40°C...+70°C]
Storage -40°F…+160°F [40°C...+70°C]
Operation -40°F…+120°F [40°C...+50°C] [with speed derating
above +104°F]
Installation Altitude 0-13,000 ft [0-4000 m]
above sea level
[with 5%/3000ft current derating above 3000ft]
Earth Leakage Current <=9 mA to PE
Power Conductor Size [Cord] Minimum 16AWG 3 Conductors rated 300VAC, use Copper Conductors
only.
For permanent connection only.
Max. Permissible Control Ca-
ble Length
100 ft un-shielded
Enclosure IP54/ NEMA 3
Protection Measures Against Short circuit, earth fault, phase loss, over voltage, under voltage, motor
stalling, over temperature, motor overload, communication loss
Environment For indoor use/outdoor
Thermal Overload Protection Drive provides internal overload protection for the motor
Pollution Degree 2
Overvoltage Category Category lll
Supply Earthing System TN-S
Impulse Voltage 2500V
Working System Voltage 150V
Packaged Fan Weight 98 lbs [44.5 kgs]
Overall Fan Weight
[no mount]
85 lbs [38.5 kgs]
LED Light Kit Weight 1.542 lbs [0.669 kgs]


Product specificaties

Merk: SchwankAir
Categorie: Ventilator
Model: MonsterFans MF-ST09-WH

Heb je hulp nodig?

Als je hulp nodig hebt met SchwankAir MonsterFans MF-ST09-WH stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ventilator SchwankAir

Handleiding Ventilator

Nieuwste handleidingen voor Ventilator

Livoo

Livoo DOM510 Handleiding

20 December 2024
Orava

Orava SF-13 Handleiding

18 December 2024
EMOS

EMOS P56PR2 Handleiding

14 December 2024
Midea

Midea FTS30-13AR Handleiding

14 December 2024
Midea

Midea FTS35-9AR Handleiding

14 December 2024
Midea

Midea FTS30-9AR Handleiding

14 December 2024