Powerhouse 2000Wi Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Powerhouse 2000Wi (40 pagina's) in de categorie Generator. Deze handleiding was nuttig voor 20 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/40
2000Wi OM
2000Wi Digital Inverter Generator
By POWERHOUSE®
OWNER’S MANUAL
PLEASE READ THIS MANUAL
CAREFULLY BEFORE USING
2 2000Wi OM
Quick Start Guide
Use outdoors only. Generators produce carbon monoxide
a poisonous, colorless, odorless gas that can cause death or
serious injury.
Always operate on a level surface
Keep away from rain, snow or other wet conditions
Keep away from smoking materials, sparks, and other sources
of combustion when refueling.
Pre-Operation:
1. Add oil by removing the maintenance panel and inspecting the dipstick. Fill the oil reservoir
with 15.6 oz. (460 ml) of oil or to the full mark on the dipstick. Use appropriate grade,
high-detergent, premium quality, 4-stroke engine oil. Use SAE 15W-40 viscosity oil unless
operating at ambient temperatures below 32° F (0° C). For temperatures below 32° F, use
SAE 0W- viscosity oil See page 14 for more information about operating at extreme 40 .
temperatures.
2. Carefully add regular unleaded automotive gasoline up to the shoulder of the fuel strainer. To
avoid spilling fuel, use care to not ll too quickly or over ll. Avoid getting dirt, dust, or water in
the fuel tank. Do not use a blend that contains more than 10% ethanol. Do not use gasoline
containing methanol. An octane rating of 87 or higher is recommended.
Operation:
1. Ensure that no loads have been connected to the AC receptacles.
2. Open the fuel valve. If the fuel tank was empty, it may also be necessary to pump the primer
bulb 15 to 20 times to get fuel to the carburetor.
3. Push the engine switch on the control panel to the n. ―ON‖ positio
4. Move the choke lever to the START position. ― ‖
5. Pull the starter grip lightly until resistance is felt, then pull briskly out. Repeat until the engine
starts.
6. Move the choke lever to the position after the engine warms up. RUN
7. The green ―RUN‖ light will illuminate when the generator is ready for use. Before connecting
any loads, ground the generator with a length of heavy cable, connecting the generator’s
grounding terminal to an external ground source.
8. Make sure that all appliances to be connected have been switched o and are in good working
order. Conrm that the combined electrical rating of the appliances does not exceed that of
the generator.
9. Connect the appliance to the appropriate receptacle on the generator’s control panel.
10. To minimize fue consumption and noise, push the economy switch l to the ―ON‖ position. This
setting regulates the engine’s speed so that it matches the needs of the connected loads. Do
not use the economy setting if you are connecting items with electric motors that have a high
amperage draw during startup or with appliances that cycle on and off rapidly.
In an emergency, pushing the Engine Switch on the control panel
to the “OFF” position will automatically stop the engine with or
without a load. However, repeatedly stopping the generator
without disconnecting all loads can cause damage to the
generator or appliances.
Shutdown:
1. Turn off all connected appliances and disconnect from the generator.
2. Push the engine switch on the control panel to the . ―OFF‖ position
3. Turn the fuel valve o.
3 2000Wi OM
PREFACE
Thank you for purchasing a POWERHOUSE generator.
This manual covers operation and maintenance of POWERHOUSE generator model 2000Wi.
All information in this publication is based on the latest product information available at the time of
printing.
We reserve the right to make changes at any time without notice and without incurring any obligation.
No part of this publication may be reproduced without written permission.
This manual should be considered a permanent part of the generator and should remain with it if it is
resold.
Pay special attention to statements preceded by the following words:
Indicates a strong possibility of severe personal injury or death if
instructions are not followed.
Indicates a possibility of personal injury or equipment damage if
instructions are not followed.
Gives helpful information.
If you have a problem with this generator, do not return it to the store where you purchased it.
For warranty support call -544-4449 from 8am to 6pm ET, email us at 877
warranty@powerhouse-products.com or send a fax to . 800 263 0280- -
Failure to properly follow these precautions can result in property
damage, serious injury, or DEATH!
Read all labels and the Owner's Manual before operating this
generator.
Generators produce carbon monoxide a poisonous, colorless,
odorless gas that can cause death or serious injury.
Indoor use of a generator can kill quickly. Generators should be
used outdoors only.
Generators should only be used outdoors away from garages and
open windows, but protected from rain and snow.
Check for spilled fuel or leaks. Clean and/or repair before use.
Always stop engine before refueling. Wait 5 minutes before
restarting.
Keep any source of ignition away from fuel tank, at all times.
The portable generator is not meant to be used as a permanent
back-up power system for the home. A permanently installed
stationary generator is designed to be safely used for this specic
purpose.
Our generators are designed to give safe and dependable service if
operated according to instructions. Read and understand the Owner's
Manual before operating the generator. Failure to do so could result in
personal injury or equipment damage.
©Copyright DTS Manufacturing /The Coast Distribution System, Inc. 2011


Product specificaties

Merk: Powerhouse
Categorie: Generator
Model: 2000Wi

Heb je hulp nodig?

Als je hulp nodig hebt met Powerhouse 2000Wi stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Generator Powerhouse

Handleiding Generator

Nieuwste handleidingen voor Generator