Planet IGS-1000-8T4X Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Planet IGS-1000-8T4X (19 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 12 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/19
Industrial Ethernet Switch
IGS-1000 Series
Users Manual
Table of Contents
1. Package Contents ................................................................................. 3
2. Hardware Introduction .......................................................................... 5
2.1 Switch Front Panel .........................................................................5
2.2 LED Indicators ............................................................................... 6
2.3 Switch Upper Panel ........................................................................ 8
2.4 Wiring the Power Inputs ................................................................. 9
2.5 Wiring the Fault Alarm Contact ..................................................... 11
2.6 Grounding the Device ................................................................... 12
3. Installation ........................................................................................ 13
3.1 DIN-rail Mounting Installation ....................................................... 13
3.2 Wall-mount Plate Mounting ........................................................... 14
4. ProductSpecications ......................................................................... 15
Customer Support .................................................................................... 18
3
1. Package Contents
Thank you for purchasing PLANET IGS-1000-8T4X and IGS-1000-8UP4X
Industrial Ethernet Switches. The descriptions of this IGS-1000 series are
as follows:
IGS-1000-8T4X Industrial 8-Port 10/100/1000T + 4-Port 10G SFP+
Ethernet Switch (-40~75 degrees C)
IGS-1000-8UP4X Industrial 8-Port 10/100/1000T 802.3bt PoE + 4-Port 10G
SFP+ Ethernet Switch (-40~75 degrees C)
Thehardwarespecicationsofthesemodelsareshownbelow:
Item
Model
Name
10/100/1000T
RJ45 Ports
1G/2.5G/10GX
SFP+ Slots PoE Ports Power Input
Range
IGS-1000-8T4X --8 4 DC 9~48V
IGS-1000-8UP4X 8 4 8 x 802.3bt DC 48~54V
In the following sections, the term refers to “Industrial Ethernet Switch
the IGS-1000-8T4X or IGS-1000-8UP4X.
4
Open the box of the Industrial Ethernet Switch and carefully unpack it. The
box should contain the following items:
Industrial Ethernet
Switch x 1 QR Code Sheet x 1 Wall-mount Kit x 1
Let’s get started with your PLANET product
IGS-1000-8T4X
EN Please scan the QR code to browse our online User’s Manual or Quick
Installation Guide and follow the instructions to complete the setup.
User's Manual
DE
Bitte scannen Sie den QR Code sie werden per Browser zur
Bedienungsanleitung oder Schnellanleitung weiter geleitet. Folgen Sie den
Anweisungen um die Installation abzuschließen.
FR Veuillez scanner le code QR pour obtenir notre Notice d’Utilisation en
ligne ou notre Guide d’Installation Rapide et suivez les instructions pour
compléter la conguration
ES
Escanee el código QR para encontrar el Manual del Usuario en línea o
la Guía de Instalación Rápida y siga las instrucciones para completar la
conguración.
IT Scansiona il codice QR per consultare online il Manuale utente o la Guida di
installazione rapida e segui le istruzioni per completare la congurazione.
PT Por favor, escaneie o QR code para navegar no Manual do Usuário ou Guia
de Instalação Rápida. Siga as instruções para completar a conguração.
PL
Zeskanuj kod QR, aby otworzyć naszą internetową instrukcję obsługi
lub instrukcję szybkiej instalacji. Postępuj zgodnie z instrukcjami, aby
zakończyć poprawną kongurację.
RU One word modify: Отсканируйте QR-код, чтобы просмотреть наше
онлайн-руководствопользователя или руководство по быстрой
настройке, и следуйте инструкциям для завершения настройки
RO Te rugam sa scanezi codul QR, pentru a descarca User’s Manual sau Quick
Installation Guide si a urmari instructiunile necesare in nalizarea instalarii
AR
Need more help?
PLANET on line FAQs:
http://www.planet.com.tw/en/support/faq
Technical Suppo rt: support@planet.com.tw
Copyright © PLANET Technology Corp. 2024.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
Part No. 2360-AH7080-000
DIN-rail Kit x 1 RJ45 Dust Cap x 8 SFP Dust Cap x 4
If any of these are missing or damaged, please contact your dealer
immediately; if possible, retain the carton including the original packing
material, and use them again to repack the product in case there is a need to
return it to us for repair.
6
Gigabit TP Interfaces (Port 1 to Port 8)
Eight 10/100/1000BASE-T RJ45 copper interfaces come with 802.3bt PoE++
type 4 injector function (For IGS-1000-8UP4X)
10Gigabit SFP+ Slots (Port 9 to Port 12)
Four 1G/2.5G/10GBASE-X SFP+ slots
2.2 LED Indicators
IGS-1000-8T4X
System
LED Color Function
P1 Green Lights: Indicates power 1 has power.
P2 Green Lights: Indicates power 2 has power.
Alarm Red Lights: Indicates either power 1 or power 2 has no power.
10/100/1000Mbps RJ45 PoE++ Ports (Port 1 to Port 8)
LED Color Function
1000
LNK/ACT Green
Lights: To indicate the port is running at 1000Mbps and
successfully established.
Blinks: To indicate that the switch is actively sending or
receiving data over that port.
10/100
LNK/ACT Amber
Lights: To indicate the port is running at 10/100Mbps
and successfully established.
Blinks: To indicate that the switch is actively sending or
receiving data over that port.
10GBASE-X SFP+ Interfaces (Port 9 to Port 12)
LED Color Function
1G/2.5G
LNK/ACT Green
Lights: To indicate the port is running at or 1000Mbps
2500Mbps and successfully established.
Blinks: To indicate that the switch is actively sending or
receiving data over that port.
10G
LNK/ACT Amber Lights: To indicate the port is running at and10Gbps
successfully established.
7
IGS-1000-8UP4X
System
LED Color Function
P1 Green Lights: Indicates power 1 has power.
P2 Green Lights: Indicates power 2 has power.
Alarm Red Lights: Indicates either power 1 or power 2 has no power.
10/100/1000Mbps RJ45 PoE++ Ports (Port 1 to Port 8)
LED Color Function
1000
LNK/ACT Green
Lights: To indicate the port is running at 1000Mbps and
successfully established.
Blinks: To indicate that the switch is actively sending or
receiving data over that port.
10/100
LNK/ACT Amber
Lights: To indicate the port is running at 10/100Mbps
and successfully established.
Blinks: To indicate that the switch is actively sending or
receiving data over that port.
PoE-in-
Use
Green
Lights: To indicate the PoE port is working in 4-pair
PoEmode(End-span+Mid-span)andoersupto95
watts of power.
Amber
Lights: To indicate the PoE port is working in 802.3at
PoE+mode(End-spanormid-span)andoersupto36
watts of power.
10GBASE-X SFP+ Interfaces (Port 9 to Port 12)
LED Color Function
1G/2.5G
LNK/ACT Green
Lights: To indicate the port is running at 1000Mbps or
2500Mbps and successfully established.
Blinks: To indicate that the switch is actively sending or
receiving data over that port.
10G
LNK/ACT Amber Lights: To indicate the port is running at 10Gbps and
successfully established.
10
2. Tighten the wire-clamp screws for preventing the wires from loosening.
123456
Power 1 Power 2Alarm
+ - + -
1. The wire gauge for the terminal block should be in the range
between 12 and 24 AWG.
2. The IGS-1000-8T4X supports DC input range of 9V to 48V.
The IGS-1000-8UP4X supports DC input range of 48V to
54V.
To avoid damage, please use the IGS-1000 Series under its
specification.
PWR1 and PWR2 must provide the while same DC voltage
operating with dual power input.
11
2.5 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block connector as
the picture shows below. Inserting the wires, the Industrial Ethernet Switch
will detect the fault status of the power failure and then forms an open circuit.
The following illustration shows an application example for wiring the fault
alarm contacts.
Fault Alarm Contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
Alarm
1 2 3 4 5 6
Insert the wires into the fault alarm contacts
1. The wire gauge for the terminal block should be in the range
between 12 and 24 AWG.
2. Alarm relay circuit accepts up to 24V with a maximum current
of 1A.


Product specificaties

Merk: Planet
Categorie: Niet gecategoriseerd
Model: IGS-1000-8T4X
Kleur van het product: Aluminium, Blue
Gewicht: 1211 g
Breedte: 76 mm
Diepte: 135 mm
Hoogte: 152 mm
Materiaal behuizing: Aluminium
Stroombron: DC
Internationale veiligheidscode (IP): IP30
LED-indicatoren: Ja
DC voltage input: 9 - 48 V
Certificering: FCC Part 15 Class A, CE
Netwerkstandaard: IEEE 802.1p, IEEE 802.3, IEEE 802.3ab, IEEE 802.3ae, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z
Temperatuur bij opslag: -40 - 75 °C
Luchtvochtigheid bij opslag: 5 - 90 procent
Ophangsysteem voor aan de muur: Ja
Switchingcapaciteit: 96 Gbit/s
MAC-adrestabel: 16000 entries
Switch type: Unmanaged
Aantal basis-switching RJ-45 Ethernet-poorten: 8
Type basis-switching RJ-45 Ethernet-poorten: Gigabit Ethernet (10/100/1000)
Throughput: 71.43 Mpps
Jumbo Frames ondersteuning: Ja
Bedrijfstemperatuur (T-T): -40 - 75 °C
Relatieve vochtigheid in bedrijf (V-V): 5 - 90 procent
DIN rail bevestiging: Ja
Store-and-forward: Ja
Aantal geïnstalleerde SFP+ modules: 4

Heb je hulp nodig?

Als je hulp nodig hebt met Planet IGS-1000-8T4X stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Planet

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd