4411 102 68142
12/2014
Data subject to change
Printed in France
www.philips.com/lighting
1/2
Mounting instructions
-30°C
Philips GearUnits ECM 330
PF>0.97MHN-SEH 2000W
MHN-LA 1000W
EN61347
MAINS
277-480V 50-60Hz
220-480V 50-60Hz 3.4
3.4 +55°C
-30°C +55°C
2100
1040
8.2-4.7
5.1-2.3
11
9.5
240
145 PF>0.97
530x143x127
530x143x127
1. Lamp currents are approximate data. For exact data refer to the lamp data sheet.
2. Ignitor on the luminaire, not on the gear unit.
Maximum distance in between e-ballast gear unit and floodlight is 80 m for 1000 W and 120 m for 2000 W versions.
See below table for recommended cable cross sections.
3. Current ripple: <10 %.
4. Earth leakage current: 480 V, 50-60 Hz <3.5 mA.
5. Output power tolerance: ±5 %.
6. Mains supply voltage fluctuation not more than -8 % and +6 % from the rated voltage of the ballast.
ECM 330
120.7
143
45
13
530
62
84
26
28.5 240
80 127.4
12.7
40
6.3
126
8
472
530
460
143
13.75
8.5
14
Warning high leakage current earth connection
essential before connecting supply
(5.1.7.1 of IEC60950-1)
1.5 mm2
1000 W
2.5 mm2
4 mm2
6 mm2
2000 W
Less then 20 m
20 to 40 m
40 to 60 m
60 to 80 m
Less then 35 m
35 to 60 m
60 to 85 m
85 to 120 m
FLOODLIGHT
CONNECTION
1.2 Nm
1
2
1
2
1.2 Nm
Exercise appropriate care in the handling of high voltages. Do not touch any conductive parts during operation.
Ensure the units are disconnected from the mains before exchanging the lamp connected to the PSU / ignitor resp. in to the end application. The residual charge
left on the capacitors is a danger to life if the units are still connected to mains!
Caution: The residual charge on the capacitors can be a danger to life even if the units are disconnected from the mains. Please handle with care!
Both electronic lamp ballast and ignitor must never be installed or operated in an explosive or volatile atmosphere. Never use the ballast or ignitor near
flammable
gases or liquids. See that there will be no moisture, dust or similar which could lead to short circuits or fire.
Before using the ballast or ignitor in any kind of outdoor application you have to take additional measures and observe special requirements. If you are uncertain,
contact Philips.
No potential isolation is provided between line input and output. Accidentally grounding of an output terminal by direct contact or arcing to GND can damage
the unit (no warranty replacement).
The unit is designed for case mounting. Due observation of electrical safety and RFI suppression code requirements is mandatory in all applications.
See that sufficient cooling of EPS and ignitor is provided.
All installation and repair work on this unit is only permitted by qualified personnel. Always comply with local safety requirements when operating the unit
uncased.
Extreme care must be taken when testing the unit live. The use of an isolating transformer is mandatory. On no account may grounded test instruments / meters
be used for this purpose!
Philips does not assume liability for disregarding of this notice, incorrect use of the EPS and ignitor or dis-regarding of any legal requirements.
This product is subject to technical changes without prior notice.
It is essential to isolate the electronic ballast/ignitor or the connected luminaire electrically from mains voltage before maintenance !
Do not attempt to handle or operate an electronic power supply (EPS) and ignitor before completely reading and understanding this notice.
Contact Philips if you are uncertain of hazards associated with these devices.
The Ballast and the ignitor produces starting voltages of up to 11 kV and electromagnetic radiation interference which are hazardous to
personnel and sensitive instrumentation.
*) After under voltage protection activation, driver start again
when Umains return to nominal value
After over voltage protection activation, driver start again when
Umains will off during 30 sec. and then return to nominal value.
Behavior after over temperature shutdown: Automatic restarting
after cool down.
4411 102 68142
12/2014
Data subject to change
Printed in France
www.philips.com/lighting
2/2
Main supply must be fused according to local safety regulations. Philips
recommends 2-phase fuse protection (fuses are not provided by
Philips).
The appropriate fuse value can be calculated as:
Plamp ×1,5/Vin Ifuse Plamp ×1,2/Vin


Product specificaties

Merk: Philips
Categorie: Niet gecategoriseerd
Model: GearUnits ECM 330
Kleur van het product: Zilver
Gewicht: 3920 g
Internationale veiligheidscode (IP): IP20
Temperatuur, in bedrijf: -30 - 30 °C
Ingangsspanning: 220/480 V
Geschikt voor gebruik binnen: Ja
Bedrijfstemperatuur (T-T): -30 - 30 °C