SYSTEM INSTALLATION AND ELECTRICAL REQUIREMENTS
Electrical Code
Note: To the display system installer: This reminder is provided to call attention to Article 820-44 of
the National Electric Code that provides guidelines for proper grounding and, in particular, speciîš¿es
that the cable ground shall be connected to the grounding system of the facility. Outlet shall be
installed near the equipment and shall be easily accessible.
Antenna discharge unit
(NEC Section 810-20)
NEC National Electric Code
Ground clamp
Electric service
equipment
Ground clamps
Power service grounding
electrode system
(NEC Art 250 Part H)
Grounding conductors
(NEC Section 810-21)
Antenna lead-in wire
Power Source
The display must be connected to a mains socket outlet with a protective grounding connection.
The mains plug is used as the disconnect device and shall remain readily accessible.
Electrical installation shall be in accordance with the applicable parts of Chapter 8 of ANSI/NFPA70.
An outdoor antenna should not be located near overhead electrical lines or any electrical circuits.
If an outside antenna is connected to the receiver, conîš¿rm that the antenna system is grounded to
protect against voltage surges and built up static charges. Section 810 of the National Electric Code,
ANSI/NFPA No 70-1984, provides information with respect to proper grounding for the mast and
supporting structure, grounding of the lead-in wire to an antenna discharge unit, size of grounding
connectors, location of antenna discharge unit, connection to grounding electrodes and requirements
for the grounding electrode.
These displays operate on 120 volt 60 Hz, AC current. Insert the power cord into a 120 volt
60 Hz outlet. Never connect the display to direct current or anything other than the speciîš¿ed voltage.
To prevent electric shock from the display, do not use with an extension cord, receptacle, or other
outlet unless the blades and ground terminal can be fully inserted to prevent blade exposure.
All secondary lines must be routed through grounded conduit and kept separate from AC line.
Note: Installation shall incorporate UL Listed external surge protection rated 2500 Vpk or less, for 150
to 300 Vac mains, installed in accordance with Article 285 of ANSI/NFPA 70 or applicable local codes.


Product specificaties

Merk: Peerless-AV
Categorie: Televisie
Model: NT553

Heb je hulp nodig?

Als je hulp nodig hebt met Peerless-AV NT553 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Televisie Peerless-AV

Handleiding Televisie

Nieuwste handleidingen voor Televisie

Cello

Cello C65SFS4K Handleiding

5 November 2024
LG

LG 42LX3Q3LA Handleiding

4 November 2024
LG

LG 43QNED776RB Handleiding

4 November 2024
LG

LG 43UR75006LK Handleiding

4 November 2024
LG

LG 43UQ75003LF Handleiding

4 November 2024
LG

LG 42LX1Q3LA Handleiding

4 November 2024
LG

LG 32LN661HBLA Handleiding

4 November 2024
LG

LG 32LT341H3ZA Handleiding

4 November 2024
LG

LG 98UT9000PUA Handleiding

4 November 2024
LG

LG 70UT8000PUA Handleiding

4 November 2024