Pagina 1/7
CT HP- 290 Family
PA27876A01
Rev. 02 3- 2017
HYDRAULIC COMPRESSION SYSTEMS
OPERATION and MAINTENANCE INSTRUCTIONS
© Panduit Corp. 2017 Original Instructions
PRECAUTIONS ...................................................................................................................... 1
INTRODUCTION ...................................................................................................................... 2
SYSTEM SPECIFICATIONS.................................................................................................... 4
OPTIONAL ACCESSORIES .................................................................................................... 4
GENERAL GUIDELINES FOR MAINTENANCE OF TOOLS .................................................. 5
PUMP OPERATION 5................................................................................................................
PREVENTIVE MAINTENANCE ............................................................................................... 6
TROUBLESHOOTING ............................................................................................................. 6
CONTACT INFORMATION 6 .....................................................................................................
WARNING: Read all safety warnings, instructions, illustrations and
specifications provided with this power tool. Failure to follow all instructions
listed below may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
E mail:
techsupport@panduit.com
www.panduit.com
Technical Support
Tel: 800 777 3300 1- - -
CT- 902HP PUMP SHOWN
© Panduit Corp. 2017 OPERATION MANUAL
CT HP- 290
FAMILY
Page: of 1 6
PRECAUTIONS
DANGER
THE USER SHOULD BE PROPERLY TRAINED
IN THE CORRECT PROCEDURES REQUIRED
FOR WORK AROUND ELECTRICAL LINES
WARNING: When performing any service on this pump
or any of its’
components, the unit MUST be disconnected
from the power
supply outlet.
WARNING: Safety glasses must be worn at all times when using the tool.
CAUTION: Be aware of the ejection of cable tie scrap from tool.
WARNING: DO NOT USE THIS TOOL ON LIVE ELECTRICAL CIRCUITS
WARNING: Keep fingers clear of crimping tool head area during tool
operation.
WARNING: DO NOT use tool in an explosive atmosphere.
CAUTION: Ear protection should be worn when operating the tool.
CAUTION – When using CT 980CH Crimp Head-
SECURE LATCH BEFORE OPERATING
FAILURE TO SECURE LATCH CAN RESULT IN SEVERE TOOL DAMAGE
AND PERSONAL INJURY.
CAUTION – When using 920CH, CT- CT CCP, CT- /920CH -930CH or
CT- 940CH Crimp Heads
DO NOT OPERATE WITHOUT DIES
© Panduit Corp. 2017 OPERATION MANUAL
CT HP- 290
FAMILY
Page: of 2 6
INTRODUCTION
The CT 902HP family of hydraulic pumps: -
- CT 902HP 110 V Hydraulic Pump with Hand Pendant Switch
- CT 902HPRCH 110 V Hydraulic Pump with Remote Control Handle
- CT 902HPRFS 110 V Hydraulic Pump with Remote Foot Switch
- CT 902HP220 220 V Hydraulic Pump with Hand Pendant Switch
- CT 902HP220RFS 220 V Hydraulic Pump with Remote Foot Switch
The CT 902HP family of hydraulic pumps are capable of providing 10,000 PSI (700 bar). Panduit recommends -
using their CT umps with 900HPH Hydraulic Pump Hose, which can crimp #8 -902HP ydraulic family of h p the CT-
AWG ; thru 1500 MCM Panduit Copper Compression Connectors and #6 AWG thru 1000 MCM Panduit Aluminum
Compression Connectors. Refer to the product packaging for wire size and crimp designations.
This manual will guide you step- -by step in operation and maintenance of your Hydraulic Pump.
If you have problems not covered, call:
1- - -800 777 3300
The information contained in this literature is based on our experience to date and is believed to be reliable. It is intended as a
guide for use by persons having technical skill at their own discretion and risk. We do not guarantee favorable results or
assume any liability in connection with its use. Dimensions contained herein are for reference purposes only. For specific
dimensional requirements consult the factory. This publication is not to be taken as a license to operate under, or a
recommendation to infringe any existing patents. This supersedes and voids all previous literature, etc.
NOTE: In the interest of higher quality and value, Panduit products are continually being improved
and updated. Consequently, pictures may vary from the enclosed product.
1) Work area safety
a) Keep work area clean and well lit. Cluttered or dark areas invite accidents.
b) Do not operate power tools in explosive atmospheres, such as in the presence of flammable
liquids, gases or dust. Power tools create sparks which may ignite the dust or fumes.
c) Keep children and bystanders away while operating a power tool. Distractions can cause you to
lose control.
2) Electrical safety
a) Always disconnect plug from outlet before performing any service on the pump.
b) Power tool plugs must match the outlet. Never modify the plug in any way. Do not use any
adapter plugs with earthed (grounded) power tools. Unmodified plugs and matching outlets will
reduce risk of electric shock.
c) Avoid body contact with earthed or grounded surfaces, such as pipes, radiators, ranges and
refrigerators. There is an increased risk of electric shock if your body is earthed or grounded.
d) Do not expose power tools to rain or wet conditions. Water entering a power tool will increase
the risk of electric shock.
e) Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power tool.
Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords
increase the risk of electric shock.
f) When operating a power tool outdoors, use an extension cord suitable for outdoor use. Use of
a cord suitable for outdoor use reduces the risk of electric shock.
g) If operating a power tool in a damp location is unavoidable, use a ground fault circuit
interrupter (GFCI)” protected supply. Use of an reduces the risk of electric shock.GFCI
3) Personal safety
a) Stay alert, watch what you are doing and use common sense when operating a power tool. Do
not use a power tool while you are tired or under the influence of drugs, alcohol or
medication. A moment of inattention while operating power tools may result in serious personal
injury.
Product specificaties
Merk: | Panduit |
Categorie: | Pomp |
Model: | CT-902HP |
Heb je hulp nodig?
Als je hulp nodig hebt met Panduit CT-902HP stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Pomp Panduit
13 Juni 2023
Handleiding Pomp
- Pomp Karcher
- Pomp Nefit
- Pomp Quigg
- Pomp Siemens
- Pomp Vaillant
- Pomp Al-ko
- Pomp Astralpool
- Pomp Bartscher
- Pomp Batavia
- Pomp Bestway
- Pomp Blumfeldt
- Pomp Bulex
- Pomp Danfoss
- Pomp Eheim
- Pomp Einhell
- Pomp Eufab
- Pomp Eurom
- Pomp Ferroli
- Pomp Fluke
- Pomp Fuxtec
- Pomp Gardena
- Pomp Generac
- Pomp Germania
- Pomp GRE
- Pomp Gude
- Pomp Hayward
- Pomp Hozelock
- Pomp Husqvarna
- Pomp Hyundai
- Pomp Lavorwash
- Pomp Makita
- Pomp Melinera
- Pomp Metabo
- Pomp Michelin
- Pomp Milwaukee
- Pomp Nibe
- Pomp Parkside
- Pomp Plantiflor
- Pomp POLARIS
- Pomp Powerfix
- Pomp Powerplus
- Pomp Ryobi
- Pomp Sanibroyeur
- Pomp Scheppach
- Pomp Silvercrest
- Pomp Toolcraft
- Pomp Trotec
- Pomp Ultimate Speed
- Pomp Velda
- Pomp Vetus
- Pomp Vivaria
- Pomp Vonroc
- Pomp Westfalia
- Pomp WHALE
- Pomp Worx
- Pomp Zipper
- Pomp Zodiac
- Pomp Oase
- Pomp OKAY
- Pomp Osram
- Pomp Ozito
- Pomp Crivit
- Pomp Black And Decker
- Pomp Wetelux
- Pomp Cannondale
- Pomp Fluval
- Pomp Sicce
- Pomp Simpson
- Pomp Tacklife
- Pomp Fieldmann
- Pomp Blackburn
- Pomp Lezyne
- Pomp Topeak
- Pomp Zéfal
- Pomp Coleman
- Pomp Outwell
- Pomp Biltema
- Pomp Comet
- Pomp Sun Joe
- Pomp Maruyama
- Pomp Little Giant
- Pomp MSW
- Pomp ESPA
- Pomp Verto
- Pomp Enermax
- Pomp Testo
- Pomp FIAP
- Pomp Neptun
- Pomp Pontec
- Pomp Alpha Tools
- Pomp Hazet
- Pomp Jabsco
- Pomp SKS
- Pomp For_Q
- Pomp Abac
- Pomp Waldbeck
- Pomp Pedrollo
- Pomp Park Tool
- Pomp DAB
- Pomp Anova
- Pomp Ubbink
- Pomp Esotec
- Pomp Wayne
- Pomp T.I.P.
- Pomp Rule
- Pomp JANDY
- Pomp Elpumps
- Pomp Hollex
- Pomp B-Air
- Pomp Baracuda
- Pomp Lifan
- Pomp Monzana
- Pomp Liberty Pumps
- Pomp BluGarda
- Pomp Grundfos
- Pomp Madimack
- Pomp Sauermann
- Pomp Eco-Flo
- Pomp Nowax
- Pomp Zoeller
- Pomp Superior Pump
- Pomp SHURflo
- Pomp EvoHeat
- Pomp Barwig
- Pomp Ribimex
- Pomp Ebara
- Pomp Perlick
- Pomp Basement Watchdog
- Pomp Ergotools Pattfield
- Pomp Zehnder Pumpen
- Pomp SANDPIPER
- Pomp Heissner
- Pomp OSIP
- Pomp Franklin Electric
Nieuwste handleidingen voor Pomp
13 November 2024
12 November 2024
12 November 2024
11 November 2024
5 November 2024
5 November 2024
4 November 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024