Panasonic CX412PZ Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Panasonic CX412PZ (31 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 31 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/31
ENDEESFRIT
CX-400
Instruction Manual
Bedienungsanleitung
Manual de Instrucciones
Manuel d’instructions
Manuale di istruzione
1
MEUML-CX400 V1.0
Thank you very much for using SUNX products. Please read this Instruction
Manual carefully and thoroughly for the correct and optimum use of this
product. Kindly keep this manual in a convenient place for quick reference.
Make sure to carry out wiring with the power OFF.
Incorrect wiring will damage the sensor.
Verify that the supply voltage including the ripple is within the rating.
If power is supplied from a commercial switching regulator, ensure that
the frame ground (F.G.) terminal of the power supply is connected to an
actual ground.
In case noise generating equipment (switching regulator, inverter motor,
etc.) is used in the vicinity of this product, connect the frame ground
(F.G.) terminal of the equipment to an actual ground.
Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
Do not use during the initial transient time (50ms) after the power supply
is switched on.
This sensor is suitable for indoor use only.
You can extend the cable up to 100m max. with 0.3mm
2 or more cable.
However, in order to reduce noise, make the wiring as short as possible.
Do not apply stress directly to the sensor cable joint by forcibly bending
or pulling.
Do not use this sensor in places having excessive vapor, dust, etc., or
where it may come in direct contact with water or corrosive gas.
Take care that the sensor does not come in direct contact with water, oil,
grease, or organic solvents such as thinners, etc.
Connector cables for the M12 pigtailed type
Connector cables for the M8 connector type
Two sets of cables are required for the thru-beam type sensor.
INSTRUCTION MANUAL
WARNING
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use
products which meet laws and standards, such as OSHA, ANSI or IEC
etc., for personnel protection applicable in each region or country.
1CAUTIONS
2PART NAMES
No. Part Description
1Stability indicator
(green)
Lights up under the stable Light or stable
Dark condition.
2Operation indicator
(orange)
Reflective type, thru-beam receiver:
lights up when the sensor output is ON.
Thru-beam emitter: power indicator.
3Sensitivity adjuster Reflective type, thru-beam receiver:
sensing range increased when turned
clockwise.
See “SENSITIVITY ADJUSTMENT” on
page 3.
4Operation mode
switch
Reflective type, thru-beam receiver:
L: Light-ON
Light-ON mode is obtained when the
operation mode switch is turned fully
clockwise (L).
D: Dark-ON
Dark-ON mode is obtained when the
operation mode switch is turned fully
counterclockwise (D).
3CONNECTOR CABLES
Type Model no. Cable length
2-core type
CN-22-C2 2m
CN-22-C5 5m
4-core type
CN-24-C2 2m
CN-24-C5 5m
Type Model no. Cable length
Straight type
UZZ80820 2m
UZZ80850 5m
Elbow type
UZZ80821 2m
UZZ80851 5m
1
4
3
2
Compact Photoelectric Sensor
CX-400 Series
2
The following symbols are used in this section.
Pin assignment
Only the thru-beam receiver incorporates the output.
NPN output type
Only the thru-beam receiver incorporates the output.
PNP output type
Only the thru-beam receiver incorporates the output.
Mount the sensor with a tightening torque of 0.5N·m or less.
Thru-beam type sensor
1Set the operation mode switch to the Light-ON mode position (L side).
2Placing the emitter and the receiver face to face along a straight line.
Move the emitter up, down, left and right to determine where light is
received with the help of the receiver’s operation indicator (orange). Set
the emitter in the middle of this area.
3Adjust the angle of the emitter by twisting it up, down, left and right.
4In a similar manner, adjust the angle of the receiver.
5Check that the stability indicator (green) lights up.
6Choose the desired operation mode, Light-ON or Dark-ON, with the
operation mode switch.
Retroreflective type sensor
Make sure to mount the sensor and the reflector at least 0.1mm
apart.
1Set the operation mode switch to the Light-ON mode position (L side).
2Placing the sensor and the reflector face to face along a straight line.
Move the reflector up, down, left and right to determine where light is
received the help of the operation indicator (orange). Set the reflector in
the middle of this area.
3Adjust the angle of the reflector by twisting it up, down, left and right.
4In a similar manner, adjust the angle of the sensor.
5Check that the stability indicator (green) lights up.
6Choose the deisred operation mode, Light-ON or Dark-ON, with the
operation mode switch.
4I/O CIRCUIT DIAGRAMS
Symbol Meaning
D Reverse supply polarity protection diode
ZDSurge absorption zener diode
Tr NPN / PNP output transistor
M12 pigtailed type Terminal name M8 connector type
1) +V
2) Not connected
3) 0V
4) Output (see note)
1
2
34 1
2
3
4
D
T
r
Z
D
+
-
±10%100mA max.
Color code of cable with connector
(Brown / 1) +V
(Blue / 3) 0V
(Black / 4)
Output (note)
Load
Internal circuit Users' circuit
12 to 24V DC
Sensor circuit
D
T
r
Z
D+
-
±10%
100mA max.
(Brown / 1) +V
(Blue / 3) 0V
(Black / 4)
Output (note) Load
12 to 24V DC
Internal circuit Users' circuit
Color code of cable with connector
Sensor circuit
5MOUNTING AND ADJUSTING
Sensor mounting
bracket (optional)
12mm M3 screws
with washers
Emitter
Receiver
Object to be sensed
Reflector
Sensor
Object to be sensed


Product specificaties

Merk: Panasonic
Categorie: Niet gecategoriseerd
Model: CX412PZ

Heb je hulp nodig?

Als je hulp nodig hebt met Panasonic CX412PZ stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Panasonic

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd