Pacific Energy Summit Insert LE Handleiding

Pacific Energy Heater Summit Insert LE

Lees hieronder de 📖 handleiding in het Nederlandse voor Pacific Energy Summit Insert LE (28 pagina's) in de categorie Heater. Deze handleiding was nuttig voor 35 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/28
070323-28 SUMMIT INSERT LE 100000089
IMPORTANT:
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE HOMEOWNER
SAVE THESE INSTRUCTIONS
MODEL:
SUMMIT INSERT LE
INSTALLATION
AND OPERATING
INSTRUCTIONS
SERIAL #
SAFETY NOTICE
If this stove is not properly installed, a house
re may result. For your safety, follow the
installation instructions. Contact local
building or re ofcials about restrictions and
installation inspection requirements in your
area.
Meets the Environmental Protection
Agency's 2020 Particulate Emission
Standards (Crib Wood).
Visit www.pacificenergy.net for the most recent version of this manual
2
SUMMIT INSERT LE 070323-28100000089
PLEASE SAVE THESE INSTRUCTIONS
This manual describes the installation and operation of the Pacific Energy, SUMMIT INSERT LE; Fireplace Insert
wood heater. This heater meets the 2020 U.S. Environmental Protection Agency's crib wood emission limits for
wood heaters sold after May 15, 2015. Under specific test conditions this heater has been shown to deliver heat
at rates ranging from 13,567 to 39,159 btu/hr.
NOTE: WE STRONGLY RECOMMEND THAT SMOKE AND CARBON MONOXIDE DETECTORS BE INSTALLED IN
THE AREA WHERE THE HEATER IS TO BE INSTALLED.
If smoke detectors have been previously installed, you may notice that they are operating more frequently. This may be
due to curing of stove paint or fumes caused by accidentally leaving the re door open. Do not disconnect the detectors.
SAFETY NOTICE: If this stove is not properly installed, a house fire may result. For your safety, follow the
installation instructions. Contact local building or fire officials about restrictions and installation inspection
requirements in you area.
Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result
in property damage, bodily injury, or even death.
HOT GLASS WILL CAUSE
BURNS.
DO NOT UCH GLASS UNTIL TO
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
Table of Contents
Rating Label 3 .......................................................................
Efciency and BTU Output 3 ...........................................
Safety 4 ................................................................................
Chimney Smoke and Creosote Formation 4 ....................
Chimney Fires 4 ...............................................................
To Avoid a Chimney Fire 5 ...............................................
In Case of a Chimney Fire 5 .............................................
Curing of the Paint Finish 5 ..............................................
Disposal of Ashes 5 .........................................................
Operation 6 ...........................................................................
Wood Selection 6 .............................................................
Do not burn: 6 ..................................................................
How to Test Your Wood 6 ................................................
Lighting a re 7 ................................................................
Normal Operation 7 .........................................................
Do not overre this heater: 7 .........................................
Convection Blower Operation 8 .......................................
Restarting After Extended or
Overnight Burns 8 ............................................................
Proper Draft 8 ..................................................................
Maintenance 9 ......................................................................
Door gasket - 9 ................................................................
Maintenance Checks 10 .......................................................
Weekly: 10 ........................................................................
Monthly 10 .......................................................................
When Cleaning the Chimney System: 10 ........................
Blower: 10 ........................................................................
Bafe: 10 ..........................................................................
Bafe Removal 10 ................................................................
Removal 10 ......................................................................
Dimensions 11 ......................................................................
Surround dimensions 11 ..................................................
Minimum Fireplace and Hearth Dimensions 12 ...................
Hearth requirements: 12 ..................................................
Ember Protection: 12 .......................................................
Clearances 14 ......................................................................
Minimum Clearances to Combustibles 14 .......................
Installation 15 .......................................................................
Fireplace Specications 15 ..............................................
Into a Masonry Fireplace 15 ............................................
Into a Factory Built Fireplace 18 ......................................
Combustion Air 18 ...........................................................
Electrical Supply 19 .........................................................
Fan Cover Removal 19 .........................................................
Surround Assembly and Installation 20 ................................
Fan Speed Controller Relocation 21 ....................................
Troubleshooting 24 ...............................................................
Firebrick Installation 25 ........................................................
Parts Diagram 28 ..................................................................
WARNING
: This product can expose you to
chemicals including ceramic bers, which are
known to the state of California to cause cancer,
and to carbon monoxide, which is known to the
state of California to cause birth defects or other
reproductive harm.
For more information, go to www.p65warnings.ca.gov.
This warning is applicable to all
PACIFIC ENERGY FIREPLACE PRODUCTS
!
3
SUMMIT INSERT LE 070323-28 100000089
PLEASE SAVE THESE INSTRUCTIONS
This manual describes the installation and operation of the Pacic Energy, SUMMIT INSERT LE Fireplace
Insert wood heater.
SAFETY NOTICE:
This wood heater needs periodic inspection and repair for proper operation. It is against federal regulations to
operate this wood heater in a manner inconsistent with the operating instructions in this manual.
Please read this entire manual before you install and use your new room heater. Failure to follow instructions
may result in property damage, bodily injury, or even death.
.
EPA Certied Emissions 1.8 grams per hour
LHV Tested Efciency 1 80%
HHV Tested Efciency 2 74%
EPA BTU Output 3 13,567 to 39,159 btu/hr
Maximum Wood Length 20 inches
Ideal Wood Length 16-18 inches
Fuel Seasoned Cord wood
1 Weighted Average Lower Heating Value (LHV) efciency as
tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. LHV assumes the moisture is
already in a vapour state so there is no loss of energy
2 Weighted Average Higher Heating Value (HHV) efciency
as tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. HHV includes the energy required
to vaporize the water in the fuel
3 The range of BTU outputs is based on efciency using
CSA B415 Performance testing of solid-fuel-burning heating
appliances and burn rates from the low and high EPA tests
using Douglas Fir dimensional lumber.
Experience will give you the right settings for proper combustion and efcient burning. Remember the correct
air inlet setting is affected by variables such as type of wood, outside temperature, chimney size and weather
conditions. With practice, you will become procient in operating your heater and will obtain the performance
for which it was designed.
Rating Label
MINIMUM CLEARANCE TO COMBUSTIBLES (MEASURED FROM INSERT BODY)
DÉGAGEMENT MINIMUM AUX COMBUSTIBLES
A) ADJACENT SIDEWALL/ 203 MM / 8 IN
PAROI LATÉRALE ADJACENTE
B) MANTEL/MANTEAU 381 MM / 15IN
C) TOP FACING/ 381 MM / 15IN
REVÊTEMENT SUPÉRIEUR
D) SIDE FACING/ 203 MM / 8 IN
REVÊTEMENT LATÉRAL
E) FIRING SIDE, CANADA (with 3in drop) 457 MM / 18 IN
FIRING SIDE, U.S.A. (with 3in. drop) 406 MM / 16 IN
EPREUVE DU FEU
F) OTHER SIDES 200 MM / 8 IN
AUTRES CÔTÉS.
INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH UNDER THE UNIT, EXTENDING A DISTANCE OF 16IN / 406MM IN FRONT
OF THE FIREPLACE OPENING FACE. - 3 in./ 76mm ABOVE ADJACENT COMBUSTIBLE FLOOR. // INSTALLER UNIQUEMENT
SUR UN COEUR NON COMBUSTIBLE SOUS L’APPAREIL, S’ÉTENDANT À UNE DISTANCE DE 16po / 406mm DEVANT LE FACE
D’OUVERTURE DU FOYER. - 3 po / 76 mm AU-DESSUS DU PLANCHER COMBUSTIBLE ADJACENT
INSTALL AND USE ONLY IN ACCORDANCE WITH PACIFIC ENERGY’S INSTALLATION AND OPERATING INSTRUCTIONS.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT CODES, RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.
INSTALL AND USE ONLY IN MASONRY FIREPLACE. NOT TO BE INSTALLED IN A FACTORY-BUILT FIREPLACE.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
COMPONENTS REQUIRED FOR INSTALLATION : FULL FLUE LINER CONFORMING TO CAN/ULC-S635 OR CAN/ULC-S640. IN U.S.A. FLUE
LINER CONFORMING TO UL-1777 OR DIRECT FLUE CONNECTION ASSEMBLY.
ELECTRICAL RATING 115V, 60HZ, 1.2 AMP. ROUTE POWER CORD AWAY FROM UNIT.
DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.
FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR ELEVATE FIRE - BUILD WOOD FIRE DIRECTLY ON HEARTH.
OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY. REPLACE GLASS ONLY WITH CERAMIC GLASS.
INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE, CREOSOTE BUILDUP MAY OCCUR RAPIDLY.
STOVE IS DESIGNED TO BURN CORDWOOD ONLY. BURNING OTHER MATERIALS MAY CAUSE DAMAGE TO STOVE OR HOME.
THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION.
CONSULT THE OWNER’S MANUAL FOR FURTHER INFORMATION.
IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE OPERATING
INSTRUCTIONS IN THE OWNER’S MANUAL
LISTED SOLID WOOD FUEL FIREPLACE INSERT /
APPAREIL DU TYPE INSERTION DE COMBUSTIBLE SOLIDE DE CHEMINÉE
CERTIFIED FOR USE IN CANADA AND U.S.A./CERTIFIE AU CANADA ET AUX ETATS-UNIS
CERTIFIED TO / CERTIFIÉ POUR:ULCS628-93/ UL1482 (2011)
CLEARANCE TO COMBUSTIBLES
ADJACENT SIDE WALL
C# 4001507
INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION DE PACIFIC ENERGY.
CONTACTEZ LES AGENTS LOCAUX DU CODE DUTIMENT OU DU SERVICE-INCENDIE, CONCERNANT LES CODES, RESTRICTIONS ET
EXIGENCES D’INSPECTION D’INSTALLATION DE VOTRE RÉGION.
INSTALLER ET UTILISER UNIQUEMENT DANS LE FOYER DE MAÇONNERIE. NE PAS INSTALLER DANS UN FOYER FABRIQUÉ EN USINE.
COMPOSANTS REQUIS POUR L’INSTALLATION : GAINE DE CHEMINÉE COMPLÈTE CONFORME À CAN/ULC-S635 OU CAN/ULC-S640. AUX
ÉTATS-UNIS : GAINE DE CHEMINÉE CONFORME À UL-1777 OU KIT DE GAINE DE CHEMINÉE À RACCORDEMENT DIRECT.
ALIMENTATION ÉLECTRIQUE : 115 V, 60 HZ, 1.2 AMP. ÉLOIGNEZ LE CORDON ÉLECTRIQUE DE L’APPAREIL. DANGER : RISQUE
D’ÉLECTROCUTION.
COUPEZ L’ALIMENTATION ÉLECTRIQUE AVANT TOUT TRAVAIL D’ENTRETIEN SUR L’APPAREIL.
POUR UTILISATION AVEC BOIS SOLIDE SEULEMENT. AUCUN PORTE-BÛCHES NI FEU SURÉLEVÉ - MONTEZ LES BÛCHES DE BOIS
DIRECTEMENT SUR L’ÂTRE. REMPLACEZ LA VITRE SEULEMENT PAR UNE VITRE EN CÉRAMIQUE.
INSPECTEZ ET NETTOYEZ LA CHEMINÉE RÉGULIÈREMENT - EN CERTAINES CONDITIONS, DES DÉPÔTS DE CRÉOSOTE PEUVENT SE
FORMER RAPIDEMENT.
UTILISEZ CET APPAREIL SEULEMENT AVEC LA PORTE DE CHARGEMENT FERMÉE. OUVREZ-LA SEULEMENT POUR ALIMENTER LE FEU. CE
POÊLE EST CONÇU UNIQUEMENT POUR BRÛLER DU BOIS DE CORDE. BRÛLER D’AUTRES MATÉRIAUX PEUT ENDOMMAGER LE POÊLE OU
LE BÂTIMENT.
070323 SUMMIT INSERT LE 100001519
Refer to Intertek’s Directory of Building Products for detailed information
MODEL / MODÈLE:
SUMMIT INSERT LE
MADE IN CANADA MANUFACTURED BY:
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8
DATE OF MANUFACTURE
1.8 g/hr
CLEARANCE TO COMBUSTIBLES
ADJACENT SIDE WALL
BC
AD
F
F
E
U.S. ENVIRONMENTAL PROTECTION AGENCY.
Certied to comply with 2020 crib wood particulate
emission standards, using test Method 28R
Certié
conforme aux normes sur les émissions de particules de 2020.
Efficiency and BTU Output
Figure 1: SUMMIT INSERT LE rating Label


Product specificaties

Merk: Pacific Energy
Categorie: Heater
Model: Summit Insert LE

Heb je hulp nodig?

Als je hulp nodig hebt met Pacific Energy Summit Insert LE stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Heater Pacific Energy

Handleiding Heater

Nieuwste handleidingen voor Heater