Pacific Energy Neo 1.6 Insert LE Handleiding

Pacific Energy Heater Neo 1.6 Insert LE

Lees hieronder de 📖 handleiding in het Nederlandse voor Pacific Energy Neo 1.6 Insert LE (28 pagina's) in de categorie Heater. Deze handleiding was nuttig voor 41 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/28
070323-28 NEO 1.6 INSERT LE 100003732
IMPORTANT:
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE HOMEOWNER
SAVE THESE INSTRUCTIONS
MODEL:
NEO 1.6 INSERT LE
INSTALLATION
AND OPERATING
INSTRUCTIONS
SERIAL #
SAFETY NOTICE
If this stove is not properly installed, a house
re may result. For your safety, follow the
installation instructions. Contact local
building or re ofcials about restrictions and
installation inspection requirements in your
area.
Meets the US Environmental Protection
Agency's 2020 Particulate Emission
Standards.
Visit www.pacicenergy.net for the most recent version of this manual
2
NEO 1.6 INSERT LE 070323-28100003732
PLEASE SAVE THESE INSTRUCTIONS
This manual describes the installation and operation of the Pacic Energy, VISTA INSERT LE; Fireplace
Insert wood heater. Please read this entire manual before you install and use your new room heater. Failure
to follow instructions may result in property damage, bodily injury, or even death.
NOTE: WE STRONGLY RECOMMEND THAT SMOKE AND CARBON MONOXIDE DETECTORS BE INSTALLED IN
THE AREA WHERE THE HEATER IS TO BE INSTALLED.
If smoke detectors have been previously installed, you may notice that they are operating more frequently.
This may be due to curing of stove paint or fumes caused by accidentally leaving the re door open. Do not
disconnect the detectors.
SAFETY NOTICE: If this stove is not properly installed, a house re may result. For your safety, follow
the installation instructions. Contact local building or re ofcials about restrictions and installation
inspection requirements in you area.
HOT GLASS WILL CAUSE
BURNS.
DO NOT UCH GLASS UNTIL TO
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
Contents
Table of Contents 2 .............................................................
Rating Label 3 .....................................................................
Safety 4 ...............................................................................
Chimney Smoke and Creosote Formation 4 ...................
Chimney Fires 4 ..............................................................
To Avoid a Chimney Fire 5 ..............................................
In Case of a Chimney Fire 5 ............................................
Curing of the Paint Finish 5 .............................................
Disposal of Ashes 5 ........................................................
Operation 6 ..........................................................................
Wood Selection 6 ............................................................
DO NOT BURN : 6 ..........................................................
How to Test Your Wood 6 ...............................................
Lighting a re 7 ...............................................................
Normal Operation 7 ........................................................
Convection Blower Operation 8 ......................................
Restarting After Extended or Overnight Burns 8 ............
Proper Draft 8 .................................................................
Ash Removal 8 ................................................................
Maintenance 9 .....................................................................
Door Gaskets - 9 .............................................................
Door Glass - 9 ................................................................
Maintenance Checks 10 ......................................................
Bafe Removal 11 ...............................................................
Dimensions 12 .....................................................................
Surround Dimensions 12 ................................................
Minimum Fireplace Dimensions 13 .....................................
Hearth Requirements: 13 ................................................
Ember Protection: 14 ......................................................
Optional Leveling Legs 14 ..............................................
Clearances 15 .....................................................................
Minimum Clearances to Combustibles 15 ......................
Installation 16 ......................................................................
Into a Masonry Fireplace 16 ...........................................
Combustion Air 19 ..........................................................
Into a Factory Built Fireplace 19 .....................................
Electrical Supply 20 ........................................................
Fan Service 20 .....................................................................
Cleaning 20 .....................................................................
To Remove the Blowers 20 .............................................
Power Cord Relocation 21 ..................................................
Backing Plate and Front Trim Installation 21 .......................
Troubleshooting 22 ..............................................................
Firebrick Installation 23 .......................................................
Firebrick Installation 24 ...................................................
Parts Diagram 26 ...................................................................
Table of Contents
STATE of CALIFORNIA
WARNING: this product can expose you to chemicals
including ceramic bers, which are known to the state
of California to cause cancer,and to carbon monoxide,
which is known to the state of California to cause birth
defects or other reproductive harm.
For more information go to www.p65warnings.ca.gov.
This warning is applicable to all
PACIFIC ENERGY FIREPLACE PRODUCTS
3
NEO 1.6 INSERT LE 070323-28 100003732
• INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION DE
PACIFIC ENERGY.
• CONTACTEZ LES AGENTS LOCAUX DU CODE DU BÂTIMENT OU DU SERVICE-INCENDIE,
CONCERNANT LES CODES, RESTRICTIONS ET EXIGENCES D’INSPECTION D’INSTALLATION
DE VOTRE RÉGION.
• INSTALLER ET UTILISER UNIQUEMENT DANS LE FOYER DE MAÇONNERIE. NE PAS
INSTALLER DANS UN FOYER FABRIQUÉ EN USINE.
• NE RACCORDEZ PAS CET APPAREIL À UN CONDUIT DE CHEMINÉE DESSERVANT UN
AUTRE APPAREIL.
• COMPOSANTS REQUIS POUR L’INSTALLATION : GAINE DE CHEMINÉE COMPLÈTE
CONFORME À CAN/ULC-S635 OU CAN/ULC-S640.
• ALIMENTATION ÉLECTRIQUE : 115 V, 60 HZ, 1.2 AMP. ÉLOIGNEZ LE CORDON ÉLECTRIQUE
DE L’APPAREIL. DANGER : RISQUE D’ÉLECTROCUTION.
• POUR UTILISATION AVEC BOIS SOLIDE SEULEMENT. AUCUN PORTE-BÛCHES NI FEU
SURÉLEVÉ - MONTEZ LES BÛCHES DE BOIS DIRECTEMENT SUR L’ÂTRE. REMPLACEZ LA
VITRE SEULEMENT PAR UNE VITRE EN CÉRAMIQUE.
• INSPECTEZ ET NETTOYEZ LA CHEMINÉE RÉGULIÈREMENT - EN CERTAINES CONDITIONS,
DES DÉPÔTS DE CRÉOSOTE PEUVENT SE FORMER RAPIDEMENT.
• UTILISEZ CET APPAREIL SEULEMENT AVEC LA PORTE DE CHARGEMENT FERMÉE.
OUVREZ-LA SEULEMENT POUR ALIMENTER LE FEU. CE POÊLE EST CONÇU UNIQUEMENT
POUR BRÛLER DU BOIS DE CORDE. BRÛLER D’AUTRES MATÉRIAUX PEUT ENDOMMAGER
LE POÊLE OU LE BÂTIMENT.
• COUPEZ L’ALIMENTATION ÉLECTRIQUE AVANT
TOUT TRAVAIL D’ENTRETIEN SUR L’APPAREIL.
• INSTALL AND USE ONLY IN ACCORDANCE WITH PACIFIC ENERGY’S INSTALLATION AND
OPERATING INSTRUCTIONS.
• CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT CODES, RESTRICTIONS AND
INSTALLATION INSPECTION IN YOUR AREA.
• INSTALL AND USE ONLY IN MASONRY FIREPLACE. NOT TO BE INSTALLED IN A FACTORY-
BUILT FIREPLACE.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
• COMPONENTS REQUIRED FOR INSTALLATION : FULL FLUE LINER CONFORMING TO CAN/
ULC-S635 OR CAN/ULC-S640. IN U.S.A. FLUE LINER CONFORMING TO UL-1777 OR DIRECT
FLUE CONNECTION ASSEMBLY.
• ELECTRICAL RATING 115V, 60HZ, 1.2 AMP. ROUTE POWER CORD AWAY FROM UNIT.
• DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.
• FOR USE WITH SOLID FUEL (CORDWOOD) ONLY. BURNING OTHER MATERIALS MAY CAUSE
DAMAGE TO STOVE OR HOME.
• DO NOT USE A GRATE OR ELEVATE FIRE - BUILD WOOD FIRE DIRECTLY ON HEARTH.
• OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY. REPLACE GLASS
ONLY WITH CERAMIC GLASS.
• INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE,
CREOSOTE BUILDUP MAY OCCUR RAPIDLY.
• THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION.
• CONSULT THE OWNER’S MANUAL FOR FURTHER INFORMATION.
• IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER
INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER’S MANUAL
LISTED SOLID WOOD FUEL FIREPLACE INSERT / APPAREIL DU TYPE INSERTION DE COMBUSTIBLE SOLIDE DE CHEMINÉE
CERTIFIED FOR USE IN CANADA AND U.S.A.
CERTIFIED TO / CERTIFIÉ POUR:ULCS628-93(R2016) / UL1482 (2011)
CLEARANCE TO COMBUSTIBLES
ADJACENT SIDE WALL
C# 4001507
070323 NEO 1.6 INSERT LE 100003731
Refer to Intertek’s Directory of Building Products for detailed information
MODEL / MODÈLE:
NEO 1.6 INSERT LE
MADE IN CANADA
MANUFACTURED BY:
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8
DATE OF MANUFACTURE
1.9 g/hr
U.S. ENVIRONMENTAL PROTECTION AGENCY.
Certied to comply with 2020 crib wood particulate
emission standards, using test Method 28R
.
DC
AB
FEF
MINIMUM CLEARANCE TO COMBUSTIBLES (MEASURED FROM SIDE OF DOOR)
DÉGAGEMENT MINIMUM AUX COMBUSTIBLES (MESURÉ DU COTE DE LA PORTE)
A) ADJACENT SIDEWALL / PAROI LATÉRALE ADJACENTE 330 MM / 13 IN
B) SIDE FACING / REVÊTEMENT LATÉRAL 240 MM / 9.5 IN
MEASURED FROM INSERT SURROUND BROW/ MESURÉ À PARTIR DE INSERT SURROUND BROW
C) TOP FACING / REVÊTEMENT SUPÉRIEUR 330 MM / 13IN
D) MANTEL / MANTEAU 330 MM / 13IN
E) EMBER PROTECTION - FIRING SIDE / EPREUVE DU FEU, CANADA 457 MM / 18 IN
FIRING SIDE, U.S.A. 406 MM / 16 IN
F) EMBER PROTECTION - SIDES / AUTRES CÔTÉS. 200 MM / 8 IN
INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH UNDER THE UNIT, EXTENDING A DISTANCE OF 16IN /
406MM IN FRONT OF THE FIREPLACE OPENING FACE. // INSTALLER UNIQUEMENT SUR UN COEUR NON
COMBUSTIBLE SOUS L’APPAREIL, S’ÉTENDANT À UNE DISTANCE DE 16po / 406mm DEVANT LE FACE
D’OUVERTURE DU FOYER.
This heater meets the 2020 U.S. Environmental Protection Agency's crib wood emission limits for wood
heaters sold after May 15, 2020 using Method 28R. Under specic test conditions this heater has been
shown to deliver heat at rates ranging from 13,500 to 23,200 Btu/hr.
1 Weighted Average Lower Heating Value (LHV) efciency as
tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. LHV assumes the moisture is
already in a vapour state so there is no loss of energy
2 Weighted Average Higher Heating Value (HHV) efciency
as tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. HHV includes the energy required
to vaporize the water in the fuel
3 The range of BTU outputs is based on efciency using
CSA B415 Performance testing of solid-fuel-burning heating
appliances and burn rates from the low and high EPA tests
using Douglas Fir dimensional lumber.
Experience will give you the right settings for proper combustion and efcient burning. Remember the correct
air inlet setting is affected by variables such as type of wood, outside temperature, chimney size and weather
conditions. With practice, you will become procient in operating your heater and will obtain the performance
for which it was designed.
Rating Label
EPA Certied Emissions 1.9 grams per hour
LHV Tested Efciency 1 78%
HHV Tested Efciency 2 72%
EPA BTU Output 3 13,494 to 23,186 btu/hr.
Maximum Wood Length 18 inches
Ideal Wood Length 16-17 inches
Fuel Seasoned Cord wood
Efficiency and BTU Output
Figure 1: 100003731 Label, Rating, NEO 1.6 Insert LE.


Product specificaties

Merk: Pacific Energy
Categorie: Heater
Model: Neo 1.6 Insert LE

Heb je hulp nodig?

Als je hulp nodig hebt met Pacific Energy Neo 1.6 Insert LE stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Heater Pacific Energy

Handleiding Heater

Nieuwste handleidingen voor Heater