Ozito OCBC-1000 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Ozito OCBC-1000 (8 pagina's) in de categorie Batterij-oplader. Deze handleiding was nuttig voor 33 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
BATTERY
CHARGER
12V 10A
INSTRUCTION MANUAL
SPECIFICATIONS
Input: 220–240V ~ 50Hz
Max. Power Rating: 160W
Max. Nominal Output: 12V DC, 10A
Battery Capacity
(STD mode): 30 200 Ah
(12V M mode): 3 60 Ah
SUPPLY Function Output max.: 8 A
RECOND charging Program: 15.3V DC / 2.5 A
Ambient Temp.: -20° °C 40C
IP Rating: IP65
Tool Weight: 0.8kg
OCBC-1000
STANDARD EQUIPMENT
3 YEAR REPLACEMENT WARRANTY*
Your product is guaranteed for a period of If 36 months from the original date of purchase.
a product is defective it will be replaced in accordance with the terms of this warranty. Warranty
excludes consumable parts, for example: .
*This product is intended for DIY use only and replacement warranty covers domestic use.
WARNING
The following actions will result in the warranty being void.
If the tool has been operated on a supply voltage other than that specified on the tool.
If the tool shows signs of damage or defects caused by or resulting from abuse, accidents
or alterations.
Failure to perform maintenance as set out within the instruction manual.
If the tool is disassembled or tampered with in any way.
Professional, industrial or high frequency use.
WARRANTY
OZITO Australia/New Zealand (Head Office) 25 Fox Drive Dandenong South, Victoria, Australia 3175.
ozito.com.au
Battery Charger
0621
IN ORDER TO MAKE A CLAIM UNDER THIS WARRANTY
YOU MUST RETURN THE PRODUCT TO YOUR NEAREST
BUNNINGS WAREHOUSE WITH YOUR BUNNINGS
REGISTER RECEIPT. PRIOR TO RETURNING YOUR
PRODUCT FOR WARRANTY PLEASE TELEPHONE OUR
CUSTOMER SERVICE HELPLINE:
Australia: 1800 069 486
New Zealand: 0508 069 486
The benefits provided under this warranty are in addition to other rights and remedies which
are available to you at law.
Our goods come with guarantees that cannot be excluded at law. You are entitled to a
replacement or refund for a major failure and for compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the
goods fail to be of acceptable quality and the failure does not amount to a major failure.
Generally you will be responsible for all costs associated with a claim under this warranty,
however, where you have suffered any additional direct loss as a result of a defective product
you may be able to claim such expenses by contacting our customer service helpline above.
TO ENSURE A SPEEDY RESPONSE PLEASE HAVE
THE MODEL NUMBER AND DATE OF PURCHASE
AVAILABLE. A CUSTOMER SERVICE REPRESENTATIVE
WILL TAKE YOUR CALL AND ANSWER ANY QUESTIONS
YOU MAY HAVE RELATING TO THE WARRANTY POLICY
OR PROCEDURE.
80%
2 h
Ah
5 h
10 h
20 h
20
50
100
200
Charging time/hours =
Battery capacity in Ah
Amperes (charging current)
Calculating the Charging Time
The charging time
depends on the
charge status of the
battery. If the battery
is fully discharged, the
approximate charging
time up to approx.
80% charged can be
calculated using the
following formula:
Note: The charging current should be 1/10 to 1/6 of the battery
capacity.
Overload Cut-Out
The charger has electronic protection against overloading, short-
circuits and swapped poles when the 12V STD, 12V AGM, 12V
Winter and 12V M programs are used. One or more fine fuses are
also fitted. If the fuse suffers a defect it must be replaced by a new
fuse with the same amp value. If necessary, please contact Ozito
customer service.
1. Red Positive Terminal Clamp (+)
2. Black Negative Terminal Clamp (-)
BATTERY CHARGER
LCD SYMBOLS
KNOW YOUR PRODUCT
1. AUTOMATIC CHARGING
SETUP & PREPARATION
5. 12V STD
6. 12V AGM
7. Winter
8. 12V M
9. Charging Volts
10. RECOND
11. Warning
12. SUPPLY
13. Charge Status
1 2 3 4
WARNING! READ AND UNDERSTAND THE WARNINGS
BEFORE SETUP AND CHARGING.
ONLINE MANUAL
Scan this QR Code with your mobile
device to take you to the online manual.
WARNING! DO NOT USE FOR CHARGING LITHIUM ION
PHOSPHATE RECHARGEABLE BATTERIES (E.G. LiFePO4)
OR OTHER LITHIUM RECHARGEABLE BATTERIES.
3. LCD
4. Mode Button
The battery charger is a microprocessor controlled automatic
charger, it is suitable in particular for charging maintenance-free
batteries and for the long-term charging and maintenance-
charging of batteries which are not in constant use, e.g. for
classic cars, recreational vehicles, lawn tractors and alike. The
integrated microprocessor enables charging in several steps. The
final charging step, maintenance charging, maintains the battery
capacity at 95–100% and therefore keeps the battery fully charged
at all times. The charging operation does not need to be monitored.
However, do not leave the battery unattended if you charge it over
an extended period of time, so that you can disconnect it from the
mains power supply in the event of a fault in the charger.
The battery charger is designed for mobile use only and not for
installation in caravans, mobile homes or similar vehicles. Do not
expose the charger to rain or snow.
RECOND SUPPLY
12V M12V STD 12V AGM
5 6 7 8
12119 10 13
Standard Charging Programs
12V STD:
Charging program for lead acid batteries (wet, Ca/Ca, EFB
batteries) and gel batteries. When the charger is used for the first
time, 12V STD will appear in the display.
12V AGM:
Charging program for AGM batteries Press the “Mode” button –>
switch from the 12V STD to the 12V AGM charging program.
Special Charging Programs
Winter:
The recommended charging program for cold weather
conditions (ambient temperature of -20°C to +5°C) for
normal lead acid batteries (wet / Ca/Ca batteries) Press the
“Mode” button –> switch from the 12V AGM to the “Winter”
charging program.
12V M - Maintenance Mode:
Charging program for batteries with a low capacity (max. 2A)
3 - 60Ah and for trickle charging of all batteries. Press the “Mode”
button –> switch from the “Winter” to the “12 M” charging
program.
RECOND - Restoration Charging:
Charging program with higher end-of-charge voltage and constant
current charging, used only for restoring the charging capability
of lead acid batteries (not for AGM or GEL) which have undergone
exhaustive discharge. Only use this program for a short time and
under supervision.
The RECOND process must be checked every half an hour and
must never exceed a time of 4 hours. Refer to the instructions
supplied by the battery manufacturer.
Only use the RECOND program for lead acid batteries and only
as described below. Take care to avoid spilling any battery
acid. Battery acid is aggressive. Read and observe the safety
information.
Never use for a battery which is of sealed design (VRLA battery
such as, e.g. AGM or GEL battery). Refer to the instructions
supplied by the battery manufacturer.
Only use for batteries which are free-standing and have been
taken out of the car, not while installed in your car with a
connection to the car’s electrical system. The higher charging
voltage could damage the electrical system.
Note: To go to this program, the “Mode” button must be pressed
for 5 seconds.
2. LCD SYMBOLS 3. CHARGING PROGRAMS
12V STD: Charging a 12V battery (lead acid battery and GEL
battery.
12V AGM: Charging a 12V AGM battery.
Winter: Charging a 12V battery (lead acid battery, AGM battery
and GEL battery) in winter mode with an ambient temperature of
-20 C to +5 C.° °
12V M - Maintenance Mode: Charging a 12V battery (lead
acid battery, AGM battery and GEL battery) in charge maintenance
mode.
Charging Volts: Charging voltage in volts, faulty battery (BAt)
/ fully charged (FUL) / connected with reverse polarity or short-
circuit at the clamps (Err).
RECOND - Restoration Charging: Restoration of the charging
capability of discharged lead acid batteries with higher charging
voltage.
Warning - Fault Indictor:
If the voltage of the battery is less than 3.5V or more than 15V.
The battery is either unsuitable for charging or is defective. It is
also possible that other battery errors or faults can mean that the
battery cannot be charged.
If the terminal clamps are connected to the battery terminals
with the wrong polarity. The protection against swapped poles
ensures that the battery and charger do not get damaged. Remove
the charger from the battery and start the charging process from
the beginning again.
If there is a short-circuit between the two terminal clamps (the
metal parts of the clamps come into contact with each other).
The protection against short-circuits ensures that the battery and
charger do not get damaged.
SUPPLY: Power supply - when charging a battery. Enables the
battery charger to be used as a buffer power supply as well, e.g.
while changing a battery or for the operation of 12V d.c. devices
(function output max. 8A).
Charge Status: Charge status of the battery in percent (1
increment = 25%) and charging process (increment lit = the
battery has reached the charge level shown; increment in the
battery symbol flashes = the battery is being charged to the next
charge level; all increments are lit = the battery is fully charged).
WARNING! DO NOT CHARGE ANY FROZEN BATTERIES.


Product specificaties

Merk: Ozito
Categorie: Batterij-oplader
Model: OCBC-1000

Heb je hulp nodig?

Als je hulp nodig hebt met Ozito OCBC-1000 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Batterij-oplader Ozito

Handleiding Batterij-oplader

Nieuwste handleidingen voor Batterij-oplader